Phone
13681394298
-
Address
0935, 2nd Floor, Building 9, No. 4 Anningzhuang Road, Xisanqi, Haidian District, Beijing
Beijing Heng'an Ruifeng Technology Co., Ltd
13681394298
0935, 2nd Floor, Building 9, No. 4 Anningzhuang Road, Xisanqi, Haidian District, Beijing
Handheld four in one gas alarmThe alarm point can be set according to user requirements, with a two-level sound and light alarm function;
Handheld four in one gas alarm. This instrument adopts four high brightness alarm indicator lights and one charging indicator light. The instrument can be charged by a 5V or USB interface power supply;
Handheld four in one gas alarm has parameter backup function, which can restore factory settings and prevent misoperation;
Handheld four in one gas alarm. This instrument adopts a crocodile shaped back clip to prevent the instrument from falling off. Simultaneously configure leather cases; Long continuous working time, exceeding 12 hours.
Technical parameters:
|
TECHNICAL INDEX |
parameter |
||||
|
Detect gas |
Methane(CH4)/Combustible gas(LEL)Oxygen(O2)Carbon monoxide(CO)Hydrogen sulfide(H2S) |
||||
|
Methane(CH4) |
|||||
|
measuring range |
(0.00-5.00)%vol |
||||
|
error |
( 0.00~1.00 ) %vol:±0.10% )%CH4 ( 1.00~3.00 ) %vol: True value±10% ( 3.00~5.00 ) %vol:±0.30% %CH4 |
||||
|
Corresponding time |
≤20S ( T90 ) |
||||
|
resolution |
0.01%vol |
alarm point |
1.00%vol(Full range adjustable) |
||
|
Combustible gas(LEL) |
|||||
|
measuring range |
(0-100)%LEL |
||||
|
error |
±10% |
||||
|
Corresponding time |
≤20S ( T90 ) |
||||
|
resolution |
1%LEL |
alarm point |
20%LEL(Full range adjustable) |
||
|
Oxygen(O2) |
|||||
|
measuring range |
(0.0-30.0)%vol |
||||
|
error |
( 0.0~5.0 ) % O2:±0.5% O2 ( >5.0~30.0 )% O2:0.9% O2 |
||||
|
Corresponding time |
≤35S ( T90 ) |
||||
|
resolution |
0.1%vol |
alarm point |
18.0%vol(Full range adjustable) 25.0%vol(Full range adjustable) |
||
|
Carbon monoxide(CO) |
|||||
|
measuring range |
0~1000 )ppm |
||||
|
error |
0~20 )ppm:±2ppm( >20~100 )ppm:±4ppm (> 100~500 )ppm: True value±5% ( >500~1000)ppm: True value±6% |
||||
|
Corresponding time |
≤45S ( T90 ) |
||||
|
resolution |
1ppm |
alarm point |
24%vol(Full range adjustable) |
||
|
hydrogen sulfide |
|||||
|
measuring range |
0–100)ppm |
||||
|
error |
( 0-50 ) ppm:±3ppm (> 50-100)ppm: Measurement value ±10% |
||||
|
response time |
≤45S ( T90 ) |
||||
|
resolution |
1ppm |
alarm point |
10ppm(Full range adjustable) |
||
|
Display mode
|
Color screenLCD |
||||
|
alarm sound Grade strength |
75dB |
Alarm method |
Sound, light alarm, vibration |
||
|
Alarm indication Indicator lamp |
Not less than20Visible at meters |
Sensor lifespan |
≥1year |
||
|
Working current |
>90mA |
Continuous working hours |
> 12hour |
||
|
model No |
PL123450 |
Battery short-circuit current |
2A |
||
|
charging time |
4-5hour |
protection grade |
IP54 |
||
|
operation temperature |
-20℃ to 40℃ |
outline dimension(MM) |
130×66×30 |
||