Platinous series Heyuan multi box drug refrigerated container
Conduct stability testing on pharmaceutical companies to determine the expiration date of drugs. The product meets the long-term, accelerated, and intermediate tests in the national pharmacopoeia, FDA, ICH, and other relevant standards, as well as the 40 ℃, 20% R.H low humidity tests for special drugs such as large infusion solutions. This series of products can ensure stable and reliable test results and a long service life.

*Characteristics of Platinous series Heyuan multi box drug refrigerated container
High strength and high reliability structural design - ensuring the high reliability of the equipment;
The studio material is SUS304 stainless steel - with strong corrosion resistance, cold and hot fatigue function, and long service life;
High density polyurethane foam insulation material - ensuring minimal heat loss;
Surface spraying treatment - ensuring the long-lasting anti-corrosion function and appearance life of the equipment;
High strength heat-resistant silicone rubber sealing strip - ensures high sealing performance of equipment doors;
Multiple optional functions (such as test holes, recorders, water purification systems, etc.) ensure that users have multiple functions and testing needs;
Large area electric anti frost observation window and concealed lighting - can provide good observation effect;
Environmentally friendly refrigerants - ensure that equipment better meets your environmental protection requirements;
*The Platinus series can be customized in size, usage indicators, and various optional features according to user requirements
*Platinus series temperature control
Can achieve temperature constant control and program control;
The full process data recorder (optional function) can achieve full process recording and traceability of the experimental process;
Each motor is equipped with overcurrent (overheating) protection/heater short-circuit protection to ensure high reliability of air flow and heating during equipment operation;
USB interface and Ethernet communication function enable the device's communication and software expansion functions to meet various customer needs;
Adopting the popular cooling control mode, the compressor cooling power can be automatically adjusted from 0% to 100%, reducing energy consumption by 30% compared to the traditional heating balance temperature control mode;
The key components for refrigeration and electrical control are all products, which improves and ensures the overall quality of the equipment;
*Platinus seriesThe equipment meets the following standards
footICH2003Q1A(2)Guiding principlesGMP 2010Stability test conditions for the Chinese Pharmacopoeia: | |||||||||
1.Accelerated test:40℃±2℃/75%RH±5%RH | |||||||||
2.Intermediate conditions:30℃±2℃/65%RH±5%RH | |||||||||
3.Long term experiment:25℃±2℃/60%RH±5%RHperhaps30℃±2℃/65%RH±5%RH | |||||||||
Execution standards:2010Guidelines for drug stability test kits in the Pharmacopoeia andGB/T10586-2006 |

Platinus seriesSpecification
Model ※ 1 |
PR-80 |
PR-150 |
PR-225 |
PR-408 |
PR-800 |
PL-80 |
PL-150 |
PL-225 |
PL-408 |
PL-800 |
PSL-80 |
PSL-150 |
PSL-225 |
PSL-408 |
PSL-800 |
|||
Nominal internal volume (liters) |
80 |
150 |
225 |
408 |
800 |
80 |
150 |
225 |
408 |
800 |
80 |
150 |
225 |
408 |
800 |
|||
|
sexually ability ※ 2 |
temperature range |
-20~+150℃ |
-40~+150℃ |
-70~+150℃ |
||||||||||||||
Humidity range |
20~98%RH,10~85℃ |
|||||||||||||||||
temperature fluctuation |
±0.5℃ |
|||||||||||||||||
Temperature deviation |
±2.0℃ |
|||||||||||||||||
Humidity deviation |
± 3.0% RH (>75% RH) ± 5.0% RH (≤ 75% RH) |
|||||||||||||||||
heating up time |
-20-->+150℃ |
-40-->+150℃ |
-70-->+150℃ |
|||||||||||||||
≤60min |
≤70min |
≤60min |
||||||||||||||||
Cooling time |
+20-->-20℃ |
+20-->-40℃ |
+20-->-70℃ |
|||||||||||||||
≤45min |
≤60min |
≤80min |
||||||||||||||||
|
chi cun |
W |
400 |
500 |
600 |
600 |
1000 |
400 |
500 |
600 |
600 |
1000 |
400 |
500 |
600 |
600 |
1000 |
||
Internal dimensions (mm) |
H |
500 |
600 |
750 |
850 |
1000 |
500 |
600 |
750 |
850 |
1000 |
500 |
600 |
750 |
850 |
1000 |
||
D |
400 |
500 |
500 |
800 |
800 |
400 |
500 |
500 |
800 |
800 |
400 |
500 |
500 |
800 |
800 |
|||
W |
600 |
700 |
980 |
1080 |
1480 |
600 |
700 |
980 |
1080 |
1480 |
600 |
700 |
980 |
1080 |
1480 |
|||
External dimensions (mm) |
H |
1490 |
1590 |
1790 |
1900 |
2050 |
1490 |
1590 |
1790 |
1900 |
2050 |
1490 |
1590 |
1790 |
1900 |
2050 |
||
D |
945 |
1050 |
1030 |
1240 |
240 |
945 |
1050 |
1030 |
1240 |
1240 |
945 |
1050 |
1030 |
1240 |
1240 |
|||
Observation window size (mm) |
The volumes of 80, 150, 225, and 408 are 450H × 300W; the volume of 800 is 800H × 600W |
|||||||||||||||||
Temperature and humidity regulation method |
BT (H) C balanced temperature and humidity control method |
|||||||||||||||||
Environmental temperature for use |
+5~+35℃ |
|||||||||||||||||
|
material material |
casing |
Double sided galvanized steel plate, surface spray treatment |
||||||||||||||||
endosome |
Stainless steel plate SUS304 |
|||||||||||||||||
thermal insulation |
Polyurethane foam and glass fiber |
|||||||||||||||||
|
transfer joint implement |
heater |
Nickel chromium alloy electric heater |
||||||||||||||||
humidifier |
Stainless steel armored heater (humidification of water basin) |
|||||||||||||||||
blower |
centrifugal fan |
|||||||||||||||||
refrigeration compressor |
Fully enclosed low-noise rotary compressor |
|||||||||||||||||
refrigerant |
R404a |
R404a/R23 |
||||||||||||||||
Cooling method |
Mechanical compression single-stage refrigeration (air-cooled or water-cooled) |
Mechanical compression binary cascade refrigeration (air-cooled or water-cooled) |
||||||||||||||||
|
control make implement |
monitor |
7.0-inch, 640 × 480 dot matrix, TFT color LCD display (Q8-902) |
||||||||||||||||
Operation mode |
Program mode, fixed value mode |
|||||||||||||||||
Setting method |
Chinese and English menus, touch screen input |
|||||||||||||||||
Program capacity |
Editable: 269 programs. Each program has a maximum of 50 steps and can have 3200 loops (each loop step has a maximum of 32000 loops); Fixed: 269 programs; The program can be linked. The fixed value can be set to 999999 hours. |
|||||||||||||||||
Setting Range |
Temperature: Adjust according to the operating range of the device's temperature (upper limit+5 ℃, lower limit -5 ℃) |
|||||||||||||||||
Humidity: 0-100% RH (if the equipment has humidity function) | ||||||||||||||||||
display resolution |
Temperature 0.1 ℃; Time 0.1min |
|||||||||||||||||
Humidity: 0.1% RH (if the device has humidity function) | ||||||||||||||||||
input |
Three wire automatic compensation type PT100 |
|||||||||||||||||
Communication function (optional) |
RS-485 interface, capable of local and remote communication through network port and mobile phone communication (network communication control and mobile phone communication control functions are optional). The operating software can use Simplified Chinese Windows 2000 or Simplified Chinese Windows XP operating system, occupying one COM port and one USB port of the PC; Zui can simultaneously connect 254 devices; The maximum cumulative length of the cable is 1200m. |
|||||||||||||||||
control mode |
Anti integral saturation PID |
|||||||||||||||||
Curve recording function |
Equipped with battery protected RAM, it can store device settings, sampling values, and sampling time. The maximum storage time is 90 days (when the sampling period is 1 minute). |
|||||||||||||||||
USB function |
Equipped with one 2G USB flash drive and one PC software CD. Develop test programs through PC software The test curves and data recorded in the controller can be transferred to a USB drive. Directly display and print test data/curves through a PC (the curves transferred from the controller to the USB drive are in image format and cannot be modified); |
|||||||||||||||||
Auxiliary functions |
Fault alarm and cause, processing prompt function; Power outage protection function; Upper and lower temperature protection function; Timer function (automatic start and automatic stop operation); Self diagnostic function. |
|||||||||||||||||
|
offerings water ※1 |
Water supply method |
Pump lifting |
||||||||||||||||
Water storage tank |
80, 150 types: built-in water tank 10L; 225, 408, 800 types: built-in water tank 20L ※ 1 |
|||||||||||||||||
Water Quality |
Electrical resistivity>500 Ω m |
|||||||||||||||||
Power Supply |
AC220 (1 ± 10%) V (50 ± 0.5) Hz single-phase two wire+protective ground wire; *AC380 (1 ± 10%) V (50 ± 0.5) Hz three-phase four wire+protective earth wire |
|||||||||||||||||
Maximum current (A) |
14 |
17 |
20 |
26 |
*13.2 |
17 |
20 |
23 |
*11.8 |
*17.6 |
*11.8 |
*14.6 |
*17.6 |
*22 |
*30.8 |
|||
Power (kw) |
3.2 |
3.8 |
4.5 |
6 |
9 |
3.8 |
4.5 |
5.2 |
8 |
12 |
8 |
10 |
12 |
15 |
21 |
|||
Net weight (kg) |
220 |
230 |
275 |
305 |
450 |
230 |
240 |
300 |
350 |
480 |
260 |
295 |
325 |
425 |
650 |
|||
Standard configuration |
1 observation window (transparent electric heating film insulated glass), 1 cable hole (Φ 50mm) on each side, 2 sets of sample racks, 1 lighting fixture inside the box, 1 timer, 4 casters, 1 power cord (6 meters long), RS-485 interface, 1 sample power control terminal, 1 USB interface, 1 2G USB flash drive |
|||||||||||||||||
Safety device |
Leakage circuit breaker, dry burn protector (only wet heat type), water system protection device (only wet heat type), fan motor overheat protection, temperature fuse, control circuit overload short circuit protector, upper and lower limit temperature protector, cooling water undervoltage protection relay (only water-cooled type), compressor overpressure, overcurrent, overheat protection, phase sequence protection, condenser fan overcurrent protection (only air-cooled type) |
|||||||||||||||||
The models without moisture and heat functions are PM (-20 ℃), PU (-40 ℃), and PG (-70 ℃). The data was measured at a room temperature of+25 ℃ without a sample. | ||||||||||||||||||
The technical data in this document is subject to change without prior notice to Guangdong Hongzhan Technology Co., Ltd | ||||||||||||||||||
: |
Publication date: June 2013 |
|||||||||||||||||
Hongzhan has a research institution specializing in the development of environmental testing equipment, with mature environmental testing research methods and laboratories. It has gathered a group of excellent talents and experts in the industry, and a strong R&D team is driving the development direction of domestic environmental testing technology. Currently, the company has independent intellectual property rightsHigh and low temperature test chamber、High and low temperature damp heat test chamber、Fast Response Temperature Chamber、thermal shock chamberThree comprehensive test chambersHigh, low temperature, and low pressure test chamber、Solar radiation test chamberThe climate environment testing equipment and customized products such as industrial ovens, walk-in high and low temperature wet heat test chambers, and high wind speed rain test chambers are at a high level in China.