E-mail
sales@sgm7.com
- Phone
-
Address
No. 10 San Yue Road, Pujiang Town, Shanghai
Shanghai Huatong Optical Instrument Co., Ltd
sales@sgm7.com
No. 10 San Yue Road, Pujiang Town, Shanghai
| Reflection and transmissionMineralogical microscopeHPL-50 ▲Geological, mineral, metallurgical and other departments, as well as relevant higher education institutions、Research and testing in fields such as geology, chemical engineering, medicine, and pharmaceuticalsequipmentPerform single polarization observation and orthogonal polarization observation Cone light observation and microscopic photography ▲Observation of Crystal Phases in Liquid Polymer Materials, Biopolymers, and Liquid Crystal Materials、 ▲Polarization analyzer: The analyzer located inside the analysis can detect polarization180°Free rotation, cursor accuracy is6'/Grid, equipped with a polarizer locking device. Cone light observation and polarized light observation can be freely converted. Cone light observation allows for free focusing, making the cone light image clearer. | |
| HPL-50Reflection and transmissionMineralogical microscopeconfiguration table | |
| Device Name | name |
| magnification | Optical amplification:40-600Magnify the system:50-2400times |
| rack | Imported optical path design, overall die-casting of the body, more stable structure. Efficient cooling system. |
| Infinite chromatic aberration independent correction optical system. | |
| Low position coaxial coarse and fine adjustment focusing mechanism, with adjustable height of coarse and fine adjustment handwheel,Fine tune grid values0.002mm. | |
| 110/220V,50/60Hz | |
| Three eyed head | Automatic compensation hinge type triple tube pupillary distance:50-75mm, tilted30Degree, can be done100%Transparent photography,(Spectral ratio20:80) |
| eyepiece | High eye point flat field eyepiece:10X/φ22mm |
| Flat field dividing eyepiece:10X/φ20mm | |
| Polarized objective lens | Infinite stress free long-distance flat field chromatic aberration reduction4X |
| Infinite stress free long-distance flat field chromatic aberration reduction10X | |
| Infinite stress free long-distance flat field chromatic aberration reduction 25X | |
| Infinite stress free long-distance flat field chromatic aberration reduction 40X(springS) | |
| Infinite stress free long-distance flat field chromatic aberration reduction 60X(springS) | |
| Polarization analyzer | Built in analyzer180 ° adjustable, free rotation,The precision of the cursor is6'/Grid, equipped with a polarizer locking device |
| Built in push-pull Burgundy mirror with adjustable center for easy interference observation, | |
| Cone light observation and polarized light observation can be freely converted, and cone light observation can be freely focused | |
| Compensator socket, equipped with λ plate1/4λ plate and quartz wedge compensator | |
| Empty plug | |
| Polarized spotlight (polarizer) | Observation mirror with cone light,NA.1.25Center adjustable, dual guide column positioning sliding, polarizer mirror360Adjustable, with0°、45°、90°、135°、180°、225°、270°、315°There are eight scales in total |
| lighting system | Transmission system:110-240VAdaptive wide voltage,6V20WOsram halogen lamp, continuously adjustable brightness, blue, yellow, green, frosted color filter set, Abbe spotlight:NA.1.25Up and down adjustable with field of view light bar |
| Reflection system:110-240VAdaptive wide voltage,12V50WHalogen lamp, continuously adjustable brightness, plug-in polarizer, polarizer360° rotatable, with0°、90°、180°、270°There are four levels of scale adjustment and micro cursor, blue, yellow, green, and frosted color filter groups, | |
| Carrier platform | Polarized rotating stage, diameterΦ150mm,Grid value1 °, accuracy6'',360°Divide the scale equally and adjust the center,Equipped with locking device(Can be equipped with a cross movable ruler) |
| focusing system | Coarse micro coaxial, equipped with coarse adjustment and tightness adjustment device, adjustable height up and down, coarse stroke:20mmMicro motion accuracy:0.002mmEquipped with locking and limiting devices |
| Compression clamp | Tablet pressing component |
| Mobile ruler | Polarized mobile ruler |
| converter | Internally positioned inward tilting four hole adjustable center converter with objective center adjustment wrench, easy and fast adjustment |
| compensator | Quarter wavelength compensator (mica test plate, optical path difference)137nm) |
| Full wavelength compensator (gypsum test board, optical path difference)530nm) | |
| Quartz compensator, capable of continuously generating Ⅰ-Level IV interference color | |
| Photography interface | 1XCamera receiver(Cinterface) |
| Color filter | Blue color filter |
| Green color filter | |
| Yellow filter | |
| Neutral color filter | |
| fuse | 250V/3.15AΦ5X20fuse tube |
| light bulb | 6V30Whalogen bulb |
| 12V50Whalogen bulb | |
| dust cover | dust cover |
| Instruction Manual | HPL-50Instruction Manual |
| power cord | 3CCertified power cord |
| packaging | Foam upper cover |
| Foam base | |
| System Composition | Computer type(HPL-50C): 1、Mineralogical microscope 2Adapting glasses 3High definition camera4Computer |
| Digital type(HPL-50D):1、Mineralogical microscope 2Adapting glasses 3Digital camera | |
. High fidelity color reproduction using natural color matrix technology
. Global white balance and regional white balance functions
. Design of anti electromagnetic interference structure
. Convenient and fast one click device software installation, one click image acquisition and storage function
. Rich selection of photography interface accessories, suitable for the vast majoritymicroscope,Biological Microscope,polarizing microscopeMetallographic microscope,Phase contrast microscope, etc
| serial number | pixel | resolution | photography | category | layout | interface | connection method |
| 01 | 300ten thousand | 2048 X 1536 | 3.2MP | Color CMOS | 1/2” | C-Mount | USB2.0 |
| 02 | 520ten thousand | 2592 X 1944 | 5.2MP | Color CMOS | 1/2” | C-Mount | USB2.0 |
| 03 | 800ten thousand | 3264 X 2448 | 8.0MP | Color CMOS | 1/2” | C-Mount | USB2.0 |
| 04 | 910ten thousand | 3488 X 2616 | 9.1MP | Color CMOS | 1/2” | C-Mount | USB2.0 |
| 05 | 1000ten thousand | 3664 X 2748 | 10MP | Color CMOS | 1/2” | C-Mount | USB2.0 |
| 06 | 1400ten thousand | 4384 X 3288 | 14MP | Color CMOS | 1/2” | C-Mount | USB2.0 |
| The above cameras are all equipped with measurement, processing, segmentation, fusion and other functional software, with clear effects and easy use | |||||||
HToup View software Introduction to Image Processing Software
| Image acquisition: | The resolution size, capture and storage format, image attributes, color, brightness, contrast, exposure, white balance and other parameters of the image can be set, and can be used for photography, video recording, timed photography, etc. |
| Image measurement: | The image can be measured for parameters such as perimeter, perimeter, angle, area, circle diameter, and ellipse length and diameter, for example, using tools such as short lines, rectangles, irregular shapes, ellipses (circles), three-point circles, etc., and the parameters can be exported in EXCEL formatIt can synchronously display the image size ratio (i.e. scale bar), making the image size positioning more accurate |
| Image processing: | Real time dynamic adjustment of brightness, chromaticity, saturation, and red-green-The blue color can be adjusted to perform image processing such as color inversion, relief, sharpening, smoothing, graying, noise removal, rotation, flipping, and mirroring on the captured image. |
| Annotated drawing: | Convenient and efficient text annotation, arrow indication, and various geometric shape annotations. |
| Image segmentation: | Monochrome and multi-color binary threshold adjustment, corrosion and pore removal functions further accurately delineate contours, and segment images |
| Image stitching: | When the microscope can only capture partial images of the specimen, arrange the obtained partial images in order, and then use the image stitching function to obtain the global image of the entire specimen for research and storage. |
| Image Fusion: | When the thickness of the specimen is uneven or there is a height difference on the surface, due to the limitation of the depth of field of the high-power objective lens, only clear local images can be observed. Therefore, images from different focal planes can be captured, and the image fusion function can be used to obtain a complete and clear image. |
| quantity statistics | Quickly count the quantity and provide parameters such as overall and individual perimeter and area, which can be used for overall or local statistics, and the measured data can be exported. |
| Graphic and textual report: | Help you easily create experimental reports that combine text and images, provide detailed textual explanations for specimen images, and print them. |
Each set of cameras includes:
| digital camera (Standard)CInterface1.8riceUSBCable) | 1 |
| TCN-0.5Photography receiver,23,30,30.5Millimeter direct insertion interface (optional) | 1 |
| 0.01Millimeter micrometer (optional) | 1 |
| Driver and software CD | 1 |
| Certificate of Conformity | 1 |
| carton packaging | 1 |
| Product advantages: |
| Sony Japan(SONY)CompanyExView HADseriesCCDimage sensor |
| The image processing circuitUltra-FineTMColor engine rendering technology |
| sensor chipPCBACenter pre calibration process (error ±)2Pixel) |
| comply withISO9001TheISO14001TheRoHSTheCETheFCCWaiting for quality and environmental certification standards |
| |
| Product Features: |
| Extremely high sensitivity |
| Extremely high quantum efficiency |
| Extremely high signal-to-noise ratio |
| Extremely low dark current |
| Extremely low readout noise |
| Ultra long controllable exposure time |
| Advanced white balance settings |
| ROIVariable area |
| 1X1The2X2The4X4Pixel overlay enhancement(BINNING) |
| Fully enclosed high-quality aluminum alloy metal shell |
| Support platform drivers and applications:Microsoft WindowsTheMacTheLinux |
| Support multiple videosAPIinterfaceDirectShowTheTwainTheLabView |
| Data output interface:USB2.0TheUSB3.0 |
| Optical interface:C-MountTheCS-MountTheF-Mount |
| |
| Application fields: |
| |
| Bright field, phase contrast, and dark field microscopes |
| |
| Pathology, histology, and cytology |
| |
| Immunofluorescence microscope |
| |
| Green fluorescent protein(GFP)The application |
| |
| fluorescence in situ hybridization |
| |
| Calcium ion ratio analysis |
| |
| Vitality and Movement Analysis |
| |
| Deoxyribonucleic acid analysis |
| |
| metallographic microscope |
| |
| semiconductor inspection |
| |
| Manufacturing Quality Control |
| |
| Failure Analysis |
| |
| Forensic analysis |
| |
| Hematoxylin-Eosin staining observation (pathology) |
| |
| Gel imaging |
| |
| semiconductor inspection |
| |
| Solar panel inspection |
http://www.htxwj.com/ Industrial Microscope
http://www.htxwj.com/ microscope
http://www.htxwj.com/ Biological Microscope
http://www.htxwj.com metallographic microscope
http://www.htxwj.com polarizing microscope
http://www.htxwj.com Mineralogical microscope
http://www.htxwj.com Phase contrast microscope
http://www.omshtong.com/ Industrial Microscope
http://www.omshtong.com/ microscope
http://www.omshtong.com/ Biological Microscope
http://www.omshtong.com metallographic microscope
http://www.omshtong.com polarizing microscope
http://www.omshtong.com Mineralogical microscope
http://www.omshtong.com Phase contrast microscope