The XF500S-CWB integrated photovoltaic environmental monitoring instrument is an instrument used in the fields of photovoltaic power plants and new energy monitoring. The product innovatively integrates various meteorological parameters that need to be monitored for the operation and maintenance management of photovoltaic power stations into one structure, which is connected to the inverter through an RS485 interface and can replace traditional fixed photovoltaic meteorological stations.
XF500S-CWB typeIntegrated photovoltaic environmental monitoring deviceIt is an instrument used in the fields of photovoltaic power plants and new energy monitoring. The product innovatively integrates various meteorological parameters that need to be monitored for the operation and maintenance management of photovoltaic power stations into one structure, which is connected to the inverter through an RS485 interface and can replace traditional fixed photovoltaic meteorological stations.
Application field
Solar photovoltaic power station, photovoltaic resource assessment, operation and maintenance management of solar photovoltaic power station, research on atmospheric thermal balance, and scientific research on meteorological environment of solar photovoltaic power station
Integrated photovoltaic environmental monitoring deviceProduct Technical Parameters
monitoring parameters |
measurement range |
precision |
resolution |
environmenttemperature |
-40-60℃ |
±0.3℃@25℃ |
0.01℃ |
relativehumidity |
0-100%RH |
± 3% RH (<80% RH, no condensation) |
0.01%RH |
Component temperature |
-20℃~+80℃ |
≤ ±0.2℃ |
0.1℃ |
wind speed |
0-60m/s |
±(0.3+0.03V)M/S; V≤30M/S
±(0.3+0.05V)M/S; V≥30M/SV is the standard wind speed value inside the wind tunnel
|
0.01m/s |
wind direction |
0-359.9° |
± 3 ° (at wind speed of 10m/s) |
0.1° |
atmospheric pressure |
500-1100hPa |
±0.5hPa(25℃,950-1100hPa) |
0.1hPa |
sunradiation |
0~2000W/m2 |
≤ ±3% |
1W/m2 |
Total cumulative radiation |
Spectral range: 300~320nm |
Update cycle: 1 minute |
Measurement accuracy: 5% |
Operating Temperature |
-40℃—80℃ |
output signal |
RS485 communication, Modbus protocol |
power supply |
DC12-24V |
Solar radiation meter adjustment plate |
Adjustable range from 0-60 ° (with a general standard of 40 °) |
Protection level |
IP65 |
fixation method |
Sleeve type (optional adapter) |
fixed bracket |
Optional 1.5-meter and 1.8-meter brackets |
Remarks |
XF500S-CWB typeIntegrated photovoltaic environmental monitoring deviceStandard TBQ-2C-D thermoelectric principle total radiation meter,
Users can choose EKO/MS-802 (Class A), MS-60 (Class B), MS-40 (Class C) total radiation meters as optional;
Kipp&Zonen/CMP6 (Class B) and CMP10 (Class A) total radiation meters
|
Product dimensions:

MODBUS communication protocol:
Baud rate9600
Data bit:8
Stop position:1
Checkpoint: None