JHS cable 2 * 6mm2 300/500V submersible pump cable

NegotiableUpdate on 11/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

JHS cable 2 * 6mm2 300/500V submersible pump cable $r $n waterproof rubber sheathed cable is used to transmit electrical energy to submersible motors with AC voltage of 500V and below. The cable core is allowed to work at a temperature of 65 ℃ for a long time.

Product Details

JHS cable 2 * 6mm2 300/500V submersible pump cable

1、 Execution standard: Enterprise standard

2、 Purpose: JHS type submersible motor with waterproof rubber sleeve flexible cable for transmitting electrical energy on submersible motors with AC voltage of 500V and below. Under long-term immersion and high water pressure, it has good electrical insulation performance. Waterproof rubber sheathed cables have good bending performance and can withstand frequent movement.

IIIUse features
1Waterproof rubber sheathed cables are used to transmit electrical energy to submersible motors with an AC voltage of 500V or below. The cable core is allowed to work at a temperature of 65 ℃ for a long time.
2. The cable has good electrical insulation performance under long-term immersion and high water pressure, and the sheath material is required to have a small water absorption under water pressure.
3. The cable has good bending performance, is soft, and can withstand frequent movement.

4JHS cable 2 * 6mm2 300/500V submersible pump cableSpecifications and dimensions of JHS waterproof rubber sheathed cables

nominal

cross-section

1 core

3-core

Number of cores*

Nominal cross-section

(3+1) Core

Main core at 20 ℃

Direct current resistance of conductor

≤(Ω/km)

Large outer diameter

calculate

weight

big

outer diameter

calculate

weight

big

outer diameter

calculate

weight

4

9.0

100

17.0

361

3*4+1*1.5

18.0

412

4.95

6

9.5

126

19.0

463

3*6+1*4

20.0

536

3.30

10

12.5

220

24.0

762

3*10+1*6

25.0

853

1.91

16

13.5

282

26.0

972

3*16+1*6

27.0

1054

1.21

25

16.5

432

32.0

1509

3*25+1*10

33.0

1666

0.780

35

18.5

564

36.0

1988

3*35+1*16

36.5

2112

0.554

50

21.5

794

43.0

2836

3*50+1*16

43.5

2987

0.386

70

23.5

1045

47.5

3701

3*70+1*25

48.5

3961

0.272

95

25.5

1295

51.5

4590

3*95+1*35

53.5

4924

0.206

5、 Performance indicators

20℃

Conductor resistivity

≤(Ω/mm2/m)

Insulated wire core power frequency withstand voltage

Finished cable power frequency withstand voltage

Horizontal route

Sealing experiment

Rubber water absorption test under water pressure

After immersing in room temperature water for 6 hours

After immersing in room temperature water for 6 hours

20 ℃ after immersion and pressure resistance
Insulation resistance (M Ω/km)

experiment

voltage

(V)

pressurize

time

(min)

experiment

voltage

(V)

pressurize

time

(min)

No tin plating
0.0184
tin-plating
0.0210

2500

5

2500

15

100

Bend ten times (to 180 ℃) on a cylinder with a diameter of 5 times the cable and place it in 30 atmospheric pressure water tanks for 2 hours. The exposed part of the cable should not leak water

Place the protective rubber sleeve in water at 30 atmospheres and room temperature for 24 hours, with a weight increase of no more than 1.6mg/cm2

jDue to the close relationship between wire and cable products and the lives of consumers, their quality and safety directly affect the personal and property safety of consumers. Therefore, it is very important to choose wire and cable correctly:
1> Check the "CCC" certification mark. Therefore, wire and cable products are national mandatory safety certification products, and all production enterprises must obtain the "CCC" certification from the China Electrical Products Certification Committee, obtain the "CCC" certification mark, and have the "CCC" certification mark on the certificate of conformity or product.
2> Refer to the inspection report. As a product that affects personal and property safety, wires and cables have always been listed as a key focus of government supervision and inspection. Regular manufacturers are subject to periodic inspections by supervisory departments. Therefore, the seller should be able to provide inspection reports from the quality inspection department, otherwise, the quality of the product will lack basis.
3> Pay attention to packaging. The packaging of wire and cable products is the same as other products. Large and medium-sized formal enterprises that produce products that meet national standards pay great attention to product packaging. When making a purchase, pay attention to the exquisite packaging, clear printing, complete model specifications, factory name, and address.
4> Judging from its appearance, the product has a smooth and round appearance with uniform color. Wire and cable enterprises that meet national standard requirements strictly control the selection of raw materials, production equipment, and production processes in order to improve product quality and ensure that products meet national standard requirements. So, the appearance of the produced wire and cable products meets the standard requirements: smooth and round, with uniform color. The appearance of inferior products is rough and dull. For rubber insulated flexible cables, it is required that the appearance be round and the sheath, insulation, and conductor be tight and not easily peeled off. However, inferior products have rough appearance, high ellipticity, and low insulation strength of the sheath, which can be easily removed by hand.
5> Look at the conductor, the conductor has luster, and the DC resistance, conductor structure size, etc. meet the requirements of national standards. Products of wires and cables that meet national standards, whether made of aluminum or copper conductors, are relatively bright and free of oil stains. Therefore, the DC resistance of the conductors * meets national standards, has good conductivity, and high safety.
6> Measure the length. Length is the main intuitive method to distinguish between products that meet national standards and those that are of poor quality. When making a purchase, do not be tempted by cheap prices. Choose wires and cables with a length of 90m or 80m, or even without length markings. The length must meet the standard requirement of 100 ± 0.5m, which is based on a standard of 100 meters and allows for *. 5 meters.
7> In addition, when purchasing wires and cables, the purpose should also be considered. Usually, the wire current is calculated based on the power of the electrical appliance carried, and then the wire specifications are selected according to the current size.