◆ Model:LC3015 series
◆ Parameters:LC3015、 Simple structure, good stability, on-site pointer liquid level display, easy installation, capable of outputting 4-20mA signals in a two-wire system
Product Overview
The LC3015 series float level gauge has the characteristics of stable accuracy, good linearity, and simple installation. It can be read directly on site, and can also output 4-20mA remote transmission or HART communication. Its working principle is to embed a float in the measured medium. When the liquid level changes, the buoyancy received by the float also changes. In this way, the length of the spring connected to the float will change accordingly, and the spring will drive the magnetic steel to move, thereby changing the magnetic field near the Hall sensor. This change is proportional to the magnitude of the buoyancy (liquid level). The Hall sensor converts the magnetic signal into a DC signal m, which is processed by a circuit composed of a single-chip machine and other components to output a two-wire 4-20mA linear DC current signal and load a digital signal that complies with the HART protocol communication.
| LC3015 | Float level gauge | Registered model | |||||||||
| | A | Only pointer level display, no need for electricity | Basic Types | ||||||||
| B | Pointer liquid level display, output switch signal | ||||||||||
| C | Two line system4~20mA, HARTcommunication protocol | ||||||||||
| | 1 | Q235steel | Main material | ||||||||
| 2 | 321 SCS321 1Cr18Ni9Ti 1.4873 | ||||||||||
| 3 | 316Ti OCr18Ni12Mo2Ti 1.4571 | ||||||||||
| 4 | 316 SVS 316 oocr 17 by 12 mo 2 1.4401 | ||||||||||
| 5 | | ||||||||||
| 6 | special material(Please specify) | ||||||||||
| | H | External float side installation type | Installation method | ||||||||
| C | External float side bottom installation type | ||||||||||
| F | External float top side installation type | ||||||||||
| G | External float top and bottom installation type | ||||||||||
| N | Internal floating top mounted type | ||||||||||
| | 1 | Measure liquid level | Tested parameters | ||||||||
| 2 | Measurement boundary | ||||||||||
| 3 | Measure density | ||||||||||
| | 4/ | 2.5MPa/Class | pressure rating | ||||||||
| 5/ | 4.0MPa/Class | ||||||||||
| 6/ | 6.3MPa/Class | ||||||||||
| 7/ | 16.0MPa/Class | ||||||||||
| 8/ | 32.0MPa/Class | ||||||||||
| 9/ | 40.0MPa/Class | ||||||||||
| | T1 | Room temperature type-40℃~ | process temperature | ||||||||
| T2 | high-temperature type-150℃~ | ||||||||||
| T3 | low-temperature type-196℃~ | ||||||||||
| | O | No explosion-proof requirements | Explosion proof type | ||||||||
| D | flameproof typeExdIICT4~T6 | ||||||||||
| E | intrinsically safeExiaIICT4~T6 | ||||||||||
| B | Equipped with safety barriers(Refer to the user manual) | ||||||||||
| | 0 | Cylinder without jacket | additional | ||||||||
| J1 | Steam tracing tube | ||||||||||
| J2 | Steam jacket process connectionJB/T82.1-94 DN15 PN1.0 | ||||||||||
| | -□□□□ | measurement range(mm) | |||||||||
| | -□□□□ | medium densitykg/m3 | |||||||||
| ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | ↓ | |
| LC3015 | A | 1 | H | 1 | | T1 | D | J1 | 800 | 956 | Example of Selection |
| LC3015Float level gauge; Only pointer level display, no need for electrical type; Main materialQ235External float side installation type; Used for measuring liquid level; The pressure level isClass | |||||||||||