-
E-mail
liu56817@126.com
-
Phone
13760205028
-
Address
2601, Nan Guang Jie Jia Building, 3037 Shennan Middle Road, Futian District, Shenzhen
Shenzhen Times Peak Technology Co., Ltd
liu56817@126.com
13760205028
2601, Nan Guang Jie Jia Building, 3037 Shennan Middle Road, Futian District, Shenzhen
German CS Lead Reporter V2-LD500 leak detector report software
After importing the leaked data recorded by LD 500 or LD 510 into the "German CS Leak Reporter V2" software, a leak report can be automatically created on the computer with just a few clicks. No need to manually record, sort, and visualize data, saving you a lot of time.
Through this report, you can demonstrate to the operator or department manager of the compressed air system, the energy manager of the company, or the ISO 50.001 auditor which leaks have been repaired and to what extent you have reduced the company's compressed air losses. The report shows the annual savings in energy costs, such as euros, kilowatt hours of electricity, and tons of carbon dioxide emissions.
German CS Lead Reporter V2-LD500 leak detector report softwareDetails
Create a PDF or Excel leak report (sample report compliant with ISO 50001)
Create LD500 database (measurement points and troubleshooting) through leak reporting software
Import data from LD500 via USB drive
List of companies that have imported compressed air leaks
Structured and perspective data archiving, for example, one project per quarter: Q1 2021, Q2 2021, Q3 2021, Q4 2021.
In addition, you can freely move or copy leaks between companies, buildings, and projects
Adjust the manufacturing parameters of LD500 through the project main view
Each leak can be individually edited
You can create leak reports for the entire company or each department.
Due to automatic report aggregation, you can preview the total leakage volume in l/min at any time and understand the relevant leakage costs each year.
In addition, the software can calculate the CO2 emissions of a single leak and the sum of all leaks, indicating to users that eliminating compressed air leaks is a component of decarbonization in the manufacturing industry.
You can see the comparison between V1 and V2 versions through the following link
CS Leak Reporter V2
Create a detailed ISO 50001 report. Display the detected leaks and their cost saving potential in an image overview. Exclusion measures can be defined for each leak, including status display - permit for 2 workstations to use
New features:
-Easy spare parts management
-Histogram function, used to record continuous improvement in compliance with ISO 50001 standards at the company or building level

