LX-AO portable Shore hardness tester suitable for hard rubber, hard resin, etc

NegotiableUpdate on 05/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The instrument pointer portable Shore hardness tester has three types of Shore hardness testers: A type, D type, and AO type. This LX-AO portable Shore hardness tester is AO type, suitable for hardness testing of shoe micro porous materials made of rubber and plastic with a compression ratio of 50% and a stress of 0.049MPa or above, and containing foaming agents in the plastic. The test results of LX-AO portable Shore hardness tester are directly indicated by the pointer on the dial of the hardness tester, which is clear and intuitive.
Product Details

Product Application

LX-AOThe portable Shore hardness tester is suitable for hardness testing of general hard rubber, hard resin, acrylic, glass, thermoplastic plastics, printed boards, fibers, etc.

Compliant with standards

LX-AOThe portable Shore hardness tester complies with the standards DiN53505, ASTMD2240, 1S0/R868, JISR7215, and strictly follows the relevant provisions of GB/T531-99, GB2411-80, HG/T2489-93, and JJG304-2003.

Product operation method

1. Place the sample on a sturdy surface and grip itLX-AOPortable Shore hardness testerKeep the pressure needle at least 12mm away from the edge of the sample.

2. Press the pressure foot steadily onto the sample, ensuring that the pressure needle is pressed vertically into the sample until the pressure foot and sample are completely in contact, and read within 1 second.

3. Measure the hardness value 5 times at different positions at least 6mm apart from the measuring points, and take the average value (for microporous materials, the measuring points should be at least 15mm apart).

4. If stable testing conditions are required to improve testing accuracy, theLX-AOPortable Shore hardness testerThe device is tested on the same model test stand produced in conjunction with it.

contrast

Specification parametersSpecs

model LX-AO
Dial value 0-100 degrees
Needle stroke 0-2.5mm
Pressure at the end of the pressure needle 0.55N-8.06N