The instrument loads the sample into a capillary viscometer under the conditions specified in the national standard GB 265-88, heats the water bath to the set temperature, and maintains it constant. Place the appropriate capillary viscometer in a temperature controlled bath and let it stand still. When the temperature reaches equilibrium, manually press the directional keys to start the experiment. After the experiment is completed, the instrument automatically calculates the test results and the experiment ends.
l• Applied to departments such as power, petroleum, chemical, commercial inspection, and scientific research;
l• Applied to oil products that require determination of their motion characteristics;
lSuitable for testing the kinematic viscosity and intrinsic viscosity of oil products.
lMicrocomputer control, automatic constant temperature.
lImported true color LCD display.
lPID temperature control technology has high temperature control accuracy.
lImported temperature sensor with sensitive response.
lConfigure lighting for easy observation of data.
lOptional refrigeration equipment for measuring low-temperature viscosity.
Environmental temperature: 5 ℃~40 ℃
Environmental humidity: ≤ 85%
Power supply: AC 220V ± 10% 50Hz ± 10%
Heating power: ≤ 1500W
Dimensions: 510mm × 360mm × 470mm
Weight: 20Kg
Temperature control range: (0-120) ℃ (0-room temperature requires additional refrigeration)
Temperature control accuracy: ± 0.05 ℃
Resolution: 0.01 ℃
Experimental holes: 4 holes
Display mode: LCD display
Clock display: year, month, day, hour, minute (working in power failure)
lAccessories Guide
lType viscometer (standard)
lCounter current viscometer (optional)
l
Precautions
If obvious faults are found in the instrument, contact the manufacturer in a timely manner,
Users are prohibited from opening and repairing it on their own.
If there is no display when turned on, please check the three core power cord interface at the back of the instrument
Is the fuse in place? If the fuse is broken, it should be replaced
Dangerous silk.
3. During each experiment, water should be added to the bathtub before opening it
power switch.
4. Before each experiment, a calibrated standard thermometer should be used to measure the instrument
Calibrate the displayed temperature and promptly correct any deviations.