High precision and stability: maximum resolution of 0.1 μ m.
Three color light column automatic conversion indicator.
□ Digital reading: The relative and absolute size values of the measurement can be switched and displayed by pressing the button.
Programming function: Parameters such as tolerance zones can be set.
Network communication: There is an RS232 (or RS485) communication interface.
Input/output: optocoupler isolated IO input/output interface.
Durable and sturdy: With rubber button operation, the instrument has good overall sealing and is not afraid of oil stains and water vapor.
□ Universality: It can be equipped with any shape of nozzle hole air side head from Φ 0.3mm to Φ 2.0mm.
Main technical parameters and usage conditions
|
Range of indication (μ m)
|
±10
|
±25
|
±50
|
|
Digital display resolution (μ m)
|
0.1
|
0.2
|
0.5
|
|
Light column resolution (μ m/lamp)
|
0.2
|
0.5
|
1.0
|
|
Total indication error (μ m) ≤
|
0.4
|
0.8
|
1.5
|
|
Repeatability (μ m) ≤
|
0.1
|
0.2
|
0.5
|
|
Indication variability (μ m) ≤
|
0.2
|
0.4
|
1.0
|
|
Initial gap (μ m)
|
30—60
|
40—80
|
40—80
|
|
External dimensions
|
60Mm (width) x 498mm (height) x 180mm (depth)
|
||
|
weight
|
About 2.8 kilograms
|
||