E-mail
info@empaer.com
- Phone
-
Address
Jinxiongda Technology Park, Huanguan South Road, Guanlan Street, Longhua District, Shenzhen
Shenzhen Anpar Technology Co., Ltd
info@empaer.com
Jinxiongda Technology Park, Huanguan South Road, Guanlan Street, Longhua District, Shenzhen
Introduction to the Network Version of the Machine Gas Cat Online Fixed 2-Aminopyridine Detector with Display Series
The machine gas cat online fixed 2-aminopyridine detector with display series network version is the most basic one in the machine gas cat series fixed 2-aminopyridine detector. The main functions include real-time display of on-site concentration detection, transmission of detection signals, LED lights and 2 sets of relay alarm functions, and built-in WIFI or ZIGBEE signals. Mechanical Cat Series Fixed 2-AminopyridineGas detectorIt is an IoT gas detector that can remotely monitor data, set parameters, and upgrade programs (customization of functions, program repair, etc.). In addition, the detector has two sets of relays (switch signals) inside, which can control equipment such as fans, sound and light alarms, solenoid valves, etc.
Product Features
★ IoT gas detector. In addition to basic network services such as remote data monitoring and remote parameter settings, remote program upgrades, program repairs, and feature customization are also available.
★ Dual core system. Faster and more secure data processing speed.
★ Dual operation mode of touch button and infrared remote control. Adopting a humanized 'touch and infrared remote control' dual operation mode. No need to open the lid under any circumstances to ensure safe use in flammable and explosive environments.
★ Multiple data display modes. The detection data of the detector can be displayed digitally or graphically (waveform).
★ MatchingAnparThe server can achieve a humanized display of the two-dimensional scene of the on-site installation area, and provide real-time monitoring of the installation points and alarm location prompts of various detectors on site
★ Built in WIFI or ZIGBEE module, which can achieve wireless signal transmission in areas with WIFI or ZIGBEE signal coverage;
Equipped with the third-generation 'COVER' series sensor module, it has temperature and humidity monitoring and compensation functions
Industrial grade EMC module, capable of handling harsh on-site environments and electrical interference;
★ Unique accessory compartment design. Can store simple manuals, remote controls, screws, and other small accessories for easy on-site use and maintenance.
★ Bilingual operating system: Machine Gas Cat online fixed 2-aminopyridine detector with display series network version that can switch between Chinese and English systems
★ Black box function: operation and alarm records, over temperature usage records, over humidity usage records, over range usage records
★ Complete reminder and alarm functions: sensor expiration reminder function, over concentration alarm function, over temperature and humidity alarm function, fault alarm function, instrument calibration reminder function, etc
★ Explosion proof design, intrinsic safety design, RoHS design
★ Self diagnostic function. The detector can monitor the working status and performance of its key hardware (key point voltage, signal, etc.).
★ Operation guide: Humanized design, with operation instructions for each function setting to prevent customer misoperation, unique in the industry
★ Zero point automatic calibration: For certain environmental applications, the instrument can achieve zero point automatic calibration function
Technical Parameter
| Project Content | Specific parameters | |
| product name | Machine Gas Cat Online Fixed 2-Aminopyridine Detector with Display Series Network Version | |
| product name | 2-aminopyridine gas transmitter, 2-aminopyridine gas probe, 2-aminopyridine gas sensor, 2-aminopyridine detector, 2-aminopyridine gas analyzer | |
| Detect gas | 2-Aminopyridine, please consult the manufacturer or refer to the attached table for other gases | |
| measuring range | Based on the on-site situation, please consult our technical support for details. | |
| Display units | Ppm, mg/m3, ppb, pphm,% VOL,% LEL (partially switchable) | |
| resolution | Determined by the detection range | |
| accuracy | ≤± 3% FS (normal accuracy); ≤± 1% FS (high precision) | |
| repeatability | ≤±1% | |
| response time | T90 is determined by sensor characteristics | |
| recovery time | T90-T10 determined by sensor characteristics | |
| Display mode | 320 * 240 high-definition color screen 2.0 inches | |
| Visual distance | ≥ 10 meters (5.0 visual acuity) | |
| system language | Chinese (default) and English are switchable | |
| operating mode | Touch buttons, infrared remote control, remote network (such as mobile app or upper computer software) | |
| detection | Diffusion type, pipeline type, flow type, pump suction type. For more information, please consult the manufacturer | |
| Sampling method | Diffuse and self-priming. | |
| Installation method | Wall mounted (wall mounted), pole mounted (horizontal or vertical), and pipe mounted. For more information, please consult the manufacturer | |
| Shell material | Subject: Alloy (anti-corrosion and anti-oxidation surface treatment). Probe: anti-corrosion alloy or 316L stainless steel | |
| Explosion proof sign | Dual explosion-proof standards Exd Ⅱ CT6 and Ex Td A21 | |
| protection grade | IP66 | |
| operation temperature | -40 ℃~70 ℃ (ordinary catalytic combustion principle sensor) -40 ℃~270 ℃ (special catalytic combustion) -40 ℃~50 ℃ (electrochemical) -20 ℃~50 ℃ (PID principle sensor) -20 ℃~50 ℃ (infrared/fluorescence gas sensor) -40 ℃~70 ℃ (thermal conductivity principle sensor) -40 ℃~420 ℃ (Zirconia principle oxygen sensor) |
|
| Working humidity | 10%~95%RH, No condensation (humidity>90% RH, optional filter for condensation) | |
| Working pressure | 0.08~0.6MPa (thermal conductivity principle sensor) 0.02-0.36MPa (Zirconia principle oxygen sensor) 86-106KPa (Other) |
|
| Temperature measurement range | -40 ℃~+120 ℃ accuracy ± 1 ℃ (with temperature compensation function) | |
| Humidity detection range | 0-100%RH, Accuracy ± 3% (with humidity compensation function) | |
| Built in wireless module | WIFI or Zigbee | |
| output signal | Types of wired output signals | RS-422+WIFI (or Zigbee)+2 relays (switch quantity) Three wire system current 4-20mA+RS-485+WIFI (or Zigbee)+2 relays (switch quantity) Voltage 0-5/10V+RS-485+WIFI (or Zigbee)+2 relays (switch quantity) Frequency signal (adjustable)+WIFI (or Zigbee)+2 relays (switch quantity) Three wire Hart+WIFI (or Zigbee)+2 relays (switch quantity) CAN bus+WIFI (or Zigbee)+2 relays (switch quantity) Note: Relay (switch quantity) specification: Output 2A@30VDC perhaps 0.6A@125VAC |
| Types of wireless output signals | WIFI、Zigbee、LORA、433M、800M、GPRS/3G/4G | |
| power consumption | Electrochemical sensor: P ≤± 2.6W Ordinary catalytic sensor: P ≤± 3.9W Low power catalytic sensor: P ≤± 2.8W Thermal conductivity sensor: P ≤± 2.9W Infrared sensor: P ≤± 3.0W PID sensor: P ≤± 2.8W |
|
| Alarm method | Panel LED alarm; Display screen character flashing and information reminder 2 sets of relay outputs; |
|
| control output | Fan, valve, sound and light alarm | |
| Protection function | Lightning and surge protection design, fault-tolerant wiring design, intermittent detection, automatic sensor protection function (optional) | |
| service life | 2 years (sensors), 5 years (instruments) | |
| power supply | 12-35VDC, Typical power supply 24VDC | |
| size | Overall dimensions: 205 * 136 * 86mm (length * width * thickness) - Basic model of the Air Cat series Wiring port size: Internal thread M20 * 1.5 (G1/2 internal thread, G3/4 internal thread 1/2NPT internal thread, NPT3/4NPT internal thread are optional); |
|
| Weight | ≥1.95kg | |
| Product Certification | Fire certification (mandatory CCCF), metrological certification CMC, explosion-proof certification CE、RoHS、 Third party metrology certification, national patent product certification Three system certifications: ISO9001, ISO14001, ISO18001 |
|
| Execution standards | GB 15322.1-2003, GB 3836.1-2010, GB 3836.2-2010, GB 3836.4-2010, GB 12476.1-2013, GB 12476.4-2010, GB 12476.5-2 013, JJF 1363-2012, JJF 1368-2012, JJF 1421-2013, JJF 1364-2012 |
|
| Standard accessory | Packaging box, instruction manual, certificate of conformity, warranty card, factory inspection report, installation bracket Remote control (included), calibration cover (optional) |
|