Welcome Customer !

Membership

Help

Shenzhen Anpar Technology Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Machine gas cat online fixed xylene detector with display series network version

NegotiableUpdate on 01/30
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Jiqi Cat online fixed xylene detector with display series network version is the most basic one in the Jiqi Cat series fixed xylene detector. The main functions include real-time display of on-site concentration detection, transmission of detection signals, LED lights and 2 sets of relay alarm functions, and built-in WIFI or ZIGBEE signals. The Jiqi Cat series fixed xylene gas detector is an IoT gas detector that can remotely monitor data, set parameters, and upgrade programs (customization of functions, program repair, etc.). In addition, the detector has two sets of relays (switch signals) inside, which can control equipment such as fans, sound and light alarms, solenoid valves, etc. ...
Product Details

Machine air cat online fixed type pairBenzene detectorIntroduction to the Network Edition with Display Series

Machine air cat online fixed pairToluene detectorThe online version with display series is a fixed pair of the Qi Cat seriesXylene detectorThe most basic one. The main functions include real-time display of on-site concentration detection, transmission of detection signals, LED lights and 2 sets of relay alarm functions, and built-in WIFI or ZIGBEE signals. Machine air cat series fixed xyleneGas detectorIt is an IoT gas detector that can remotely monitor data, set parameters, and upgrade programs (customization of functions, program repair, etc.). In addition, the detector has two sets of relays (switch signals) inside, which can control equipment such as fans, sound and light alarms, solenoid valves, etc.

Product Features

★ IoT gas detector. In addition to basic network services such as remote data monitoring and remote parameter settings, remote program upgrades, program repairs, and feature customization are also available.

★ Dual core system. Faster and more secure data processing speed.

★ Dual operation mode of touch button and infrared remote control. Adopting a humanized 'touch and infrared remote control' dual operation mode. No need to open the lid under any circumstances to ensure safe use in flammable and explosive environments.

★ Multiple data display modes. The detection data of the detector can be displayed digitally or graphically (waveform).

★ MatchingAnparThe server can achieve a humanized display of the two-dimensional scene of the on-site installation area, and provide real-time monitoring of the installation points and alarm location prompts of various detectors on site

★ Built in WIFI or ZIGBEE module, which can achieve wireless signal transmission in areas with WIFI or ZIGBEE signal coverage;

Equipped with the third-generation 'COVER' series sensor module, it has temperature and humidity monitoring and compensation functions

Industrial grade EMC module, capable of handling harsh on-site environments and electrical interference;

★ Unique accessory compartment design. Can store simple manuals, remote controls, screws, and other small accessories for easy on-site use and maintenance.

★ Bilingual operating system: Jiqi Cat online fixed xylene detector with display series network version that can switch between Chinese and English systems

★ Black box function: operation and alarm records, over temperature usage records, over humidity usage records, over range usage records

★ Complete reminder and alarm functions: sensor expiration reminder function, over concentration alarm function, over temperature and humidity alarm function, fault alarm function, instrument calibration reminder function, etc

★ Explosion proof design, intrinsic safety design, RoHS design

★ Self diagnostic function. The detector can monitor the working status and performance of its key hardware (key point voltage, signal, etc.).

★ Operation guide: Humanized design, with operation instructions for each function setting to prevent customer misoperation, unique in the industry

★ Zero point automatic calibration: For certain environmental applications, the instrument can achieve zero point automatic calibration function

Technical Parameter

Project Content Specific parameters
product name Machine gas cat online fixed xylene detector with display series network version
product name Paraxylene gas transmitter, xylene gas probe, xylene gas sensor, xylene detector, xylene gas analyzer
Detect gas For xylene and other gases, please consult the manufacturer or refer to the attached table
measuring range Based on the on-site situation, please consult our technical support for details.
Display units Ppm, mg/m3, ppb, pphm,% VOL,% LEL (partially switchable)
resolution Determined by the detection range
accuracy ≤± 3% FS (normal accuracy); ≤± 1% FS (high precision)
repeatability ≤±1%
response time T90 is determined by sensor characteristics
recovery time T90-T10 determined by sensor characteristics
Display mode 320 * 240 high-definition color screen 2.0 inches
Visible distance ≥ 10 meters (5.0 visual acuity)
system language Chinese (default) and English are switchable
operating mode Touch buttons, infrared remote control, remote network (such as mobile app or upper computer software)
detection Diffusion type, pipeline type, flow type, pump suction type. For more information, please consult the manufacturer
Sampling method Diffuse and self-priming.
Installation method Wall mounted (wall mounted), pole mounted (horizontal or vertical), and pipe mounted. For more information, please consult the manufacturer
Shell material Subject: Alloy (anti-corrosion and anti-oxidation surface treatment). Probe: anti-corrosion alloy or 316L stainless steel
Explosion proof sign Dual explosion-proof standards Exd Ⅱ CT6 and Ex Td A21
protection grade IP66
operation temperature -40 ℃~70 ℃ (ordinary catalytic combustion principle sensor)
-40 ℃~270 ℃ (special catalytic combustion)
-40 ℃~50 ℃ (electrochemical)
-20 ℃~50 ℃ (PID principle sensor)
-20 ℃~50 ℃ (infrared/fluorescence gas sensor)
-40 ℃~70 ℃ (thermal conductivity principle sensor)
-40 ℃~420 ℃ (Zirconia principle oxygen sensor)
Working humidity 10%~95%RH, No condensation (humidity>90% RH, optional filter for condensation)
Working pressure 0.08~0.6MPa (thermal conductivity principle sensor)
0.02-0.36MPa (Zirconia principle oxygen sensor)
86-106KPa (Other)
Temperature measurement range -40 ℃~+120 ℃ accuracy ± 1 ℃ (with temperature compensation function)
Humidity detection range 0-100%RH, Accuracy ± 3% (with humidity compensation function)
Built in wireless module WIFI or Zigbee
output signal Types of wired output signals RS-422+WIFI (or Zigbee)+2 relays (switch quantity)
Three wire system current 4-20mA+RS-485+WIFI (or Zigbee)+2 relays (switch quantity)
Voltage 0-5/10V+RS-485+WIFI (or Zigbee)+2 relays (switch quantity)
Frequency signal (adjustable)+WIFI (or Zigbee)+2 relays (switch quantity)
Three wire Hart+WIFI (or Zigbee)+2 relays (switch quantity)
CAN bus+WIFI (or Zigbee)+2 relays (switch quantity)
Note: Relay (switch quantity) specification: Output 2A@30VDC perhaps 0.6A@125VAC
Types of wireless output signals WIFI、Zigbee、LORA、433M、800M、GPRS/3G/4G
power consumption Electrochemical sensor: P ≤± 2.6W
Ordinary catalytic sensor: P ≤± 3.9W
Low power catalytic sensor: P ≤± 2.8W
Thermal conductivity sensor: P ≤± 2.9W
Infrared sensor: P ≤± 3.0W
PID sensor: P ≤± 2.8W
Alarm method Panel LED alarm;
Display screen character flashing and information reminder
2 sets of relay outputs;
control output Fan, valve, sound and light alarm
Protection function Lightning and surge protection design, fault-tolerant wiring design, intermittent detection, automatic sensor protection function (optional)
service life 2 years (sensors), 5 years (instruments)
power supply 12-35VDC, Typical power supply 24VDC
size Overall dimensions: 205 * 136 * 86mm (length * width * thickness) - Basic model of the Air Cat series
Wiring port size: Internal thread M20 * 1.5 (G1/2 internal thread, G3/4 internal thread
1/2NPT internal thread, NPT3/4NPT internal thread are optional);
Weight ≥1.95kg
Product Certification Fire certification (mandatory CCCF), metrological certification CMC, explosion-proof certification CE、RoHS、 Third party metrology certification, national patent product certification
Three system certifications: ISO9001, ISO14001, ISO18001
Execution standards GB 15322.1-2003, GB 3836.1-2010,
GB 3836.2-2010, GB 3836.4-2010,
GB 12476.1-2013, GB 12476.4-2010,
GB 12476.5-2 013,
JJF 1363-2012, JJF 1368-2012,
JJF 1421-2013, JJF 1364-2012
Standard accessory Packaging box, instruction manual, certificate of conformity, warranty card, factory inspection report, installation bracket
Remote control (included), calibration cover (optional)