Marine rubber sheathed flexible cable CEFR-3 * 2.5

NegotiableUpdate on 12/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Marine rubber sheathed flexible cable CEFR-3 * 2.5 $r $n Purpose: This product is suitable for transmitting electrical energy to various water structures such as river and sea vessels and offshore oil platforms.
Product Details

Marine rubber sheathed flexible cable CEFR-3 * 2.5

Usage: This product is suitable for transmitting electrical energy to various water structures such as river and sea vessels and offshore oil platforms.

Usage characteristics: The long-term allowable working temperature of the cable is 85 ℃, and the rated voltage Uo/U is 0.6/1KV. When laying, the small bending radius of the cable is as follows: the metal shielding armor type is 6 times the outer diameter of the cable. Non armored type, when the outer diameter is less than or equal to 25mm, it is 4 times the outer diameter of the cable, and when it is greater than 25mm, it is 6 times the outer diameter of the cable.

Model Name
CEFR/DA ethylene propylene insulated chloroprene sheathed marine power flexible cable, DA type, for connecting mobile electrical appliances.
5、 Technical requirements
1. It should be able to withstand 30000 one-way curve tests.
2. The cable should be able to withstand AC voltage of 3500V or DC voltage of 8400V without breakdown for 5 minutes.
3. The cable core structure, insulation resistance, insulation and sheath thickness and weight shall comply with the provisions of GB9331.2-88.
6、 Delivery requirements
1. The delivery length of cables with three cores or less and a conductor cross-section not exceeding 2.5 square meters should not be less than 150 meters, while other cables should be 100 meters.
2. Short cables with a length of no less than 20 meters are allowed to be delivered, but their quantity should not exceed 10% of the delivery length.
3. According to the agreement between both parties, any length of cable is allowed for delivery.
4. The length error should not exceed+-0.5%.

Technical Specifications
50W (HB/V level) 500W (5V level)
Flame height 20 ± 1mm 40 ± 2mm
Spray Lamp Standard IEC60695-11-4 IEC60695-11-3
Temperature detection MAX 1050 ° C ± 0.1% MAX 1050 ° C ± 0.1%
Gas flow rate 105 ± 10 ml/min 965 ± 30ml/min
Water column height<10mm 125 ± 5mm
Verification time 44 ± 2S 54 ± 2S
Flow accuracy 1.5% 1.5%
Copper block weight 1.76 g ± 0.01 g 10 ± 0.05 g
Gas category
1. The insulation resistance between the main cores of cable insulation and between the main cores and the ground wire shall not be less than 100M Ω· km when converted to+20 ℃.
2. The transition resistance of the main core shielding layer shall not exceed 3k Ω when converted to 20 ℃.
3. Product standard: MT818.5-199
4. Conductive core: Made of soft copper wire, its performance complies with GB/T3956-1997.
5. Insulation: XJ-00A rubber according to GB7594.2-1987 is used.
6. Core identification: Insulation color separation identification is used, with the main core being red, green, and white.
7. Ground wire: covered with a semi conductive rubber.