E-mail
sales@orionsh.com
- Phone
-
Address
No. 35 Tianfu Road, Jiuting Town, Songjiang District, Shanghai
Haoliwang Machinery (Shanghai) Co., Ltd
sales@orionsh.com
No. 35 Tianfu Road, Jiuting Town, Songjiang District, Shanghai


| Model number | DSF | 400A-SUS | 700A-SUS | 1000A-SUS | 1500A-SUS | — | |
| LSF/MSF/KSF | 2000A-SUS | ||||||
| Processing air volume ※ 1 | Pressure 0.69MPa | ㎥ /min | 4.2 | 6.8 | 10.9 | 14.0 | 20.0 |
| Pressure 0.75MPa | ㎥ /min | 4.5 | 7.3 | 11.7 | 15.0 | 21.5 | |
| Shell material | stainless steel | ||||||
| Scope of application | Use pressure range | MPa | 0.05 to 0.98 | ||||
| Inlet temperature range | ℃ | 5-60 | |||||
| Temperature range | ℃ | 2 to 60 | |||||
| Performance ※ 2 | filtration accuracy | DSF: 5 μ m droplet separation efficiency of 99%, LSF: 1 μ m (filtration efficiency of 99.999%), MSF: 0.01 μ m (filtration efficiency) | |||||
| 99.999%), KSF: adsorption with activated carbon fiber | Export oil concentration | wt ppm | |||||
| MSF:0.01 KSF:0.003 | pressure loss | MPa | |||||
| DSF: Initial 0.005, LSF: Initial 0.005, MSF: Initial 0.01/Usually 0.02, KSF: Initial 0.009 | Filter replacement cycle (usage time and pressure loss) ※ 3 | ||||||
| When the pressure drop reaches DSF: 0.02MPa or LSF · MSF: 0.07MPa in advance within 1 year, replace it in a timely manner | Main dimensions | Pipe connection diameter | Rc1 | Rc1½ | |||
| Rc2 | Size (section distance) | 174 | |||||
| mm | Size (total length) | mm | 532(KSF:370) | 599(KSF:429) | 709(KSF:539) | 789(KSF:619) | |
| 946(KSF:776) | Weight | 4.3 | 4.9 | 5.2 | 5.6 | 6.5 | |
| kg | Filter cartridge | 400 | 700 | 1000 | 1300 | 2000 | |
| Model : EDS/ELS/EMS/EKS | Use count | 1 | |||||
| branch | Automatic drain DSF/LSF/MSF ※ 4 | model | |||||
| FD2 | Filter replacement timer | ||||||
MSF: Standard DSF/LSF/KSF: Optional
The amount of air processed is converted into the suction state of the air compressor. (Atmospheric pressure, 32 ℃, 75%).
The air processing conditions are: inlet air pressure of 0.69, inlet air temperature of 32 ℃, inlet air dew point: -17 ℃ under atmospheric pressure (10 ℃ under pressure) (MSF, KSF), inlet oil concentration of 3wt ppm (LSF/MSF) and 0.01wt ppm (KSF).
Replace during the period of pressure loss or expiration date. The replacement cycle has no guaranteed value. In addition, the replacement cycle may be advanced depending on the product environment, operating conditions, and other factors.
All 4 automatic drains are float type.
The MSF series must be installed behind the air dryer
The KSF series must be installed behind the air dryer, LSF, and MSF.