| 口 path | DN15TheDN25TheDN50TheDN80TheDN100TheDN150TheDN200 (standard form) | |
| DN10TheDN20TheDN32TheDN40TheDN65TheDN125(Non standard type) | ||
| measurement range | Water:1~200000L/h | |
| air0.03~4000m³/h(20℃0.1013MPa) | ||
| turndown ratio | 10:1;20:1(Special type) | |
| connection method | flange connectionGB/T9112 HG 20592 DIN2501 ANSI JIS SH3406 | |
| clamp connectionSMS Tri-clamp | ||
| Other connections threaded connection ferrule connection hose connection | ||
| accuracy class | 1.5Grade;1.0level(special type) | |
| pressure rating | flange connection: | DN10~DN50≤4.0 Mpa(Maximum)32 Mpa) |
| DN65~DN150≤1.6 Mpa(Maximum)16 Mpa) | ||
| DN200≤1.0Mpa(Maximum)10 Mpa) | ||
| clamp connection | ≤4.0 Mpa | |
| Other connections | Made according to user requirements | |
| medium temperature | Room temperature type:-20℃~100℃; | |
| High temperature type:100℃~450℃ | ||
| PTFEType:0℃~80℃ | ||
| ambient temperature | On site type:-30℃~120℃ | |
| Remote transmission type:-20℃~80℃ | ||
| PTFEType:0℃~80℃ | ||
| power supply | 12~36VDC 4-20mAtwo-wire system | |
| 220VAC 50HzAC power supply | ||
| battery-powered Can be used continuously | ||
| output load | 500Ω24VDuring power supply) | |
| Cable interface | M20X1.5;½NPT; G½ | |
| Protection level | IP65 | |
| medium viscosity | DN15: the <5mPa.s | |
| DN25: the <250mPa.s | ||
| DN50~DN150: the <300mPa. s | ||
| Sanitary type | surface finishRa≤0.8Mm | |
| Jacket type | The standard jacket connection is a flange connection,The connection standard is:GB/T9119-2000 DN15 PN16 RFOther connections can be customized according to user requirements. | |
5、 Product selection
| SLSeries metal tube float flowmeter | say bright | |||||||||
| SL | An pretend form formula | H1 |
| Vertical installation with bottom in and top out | ||||||
| H2 |
| Vertical installation with upper and lower outlets | ||||||||
| H3 |
| Vertical thread with downward entry and upward exit | ||||||||
| S1 |
| Horizontal installation with left in and right out | ||||||||
| S2 |
| Horizontal installation with right in and left out | ||||||||
| ST |
| Horizontal installation of spring structure | ||||||||
| SW |
| Horizontal installation threaded connection | ||||||||
| DC |
| Bottom in and side out | ||||||||
| CC |
| Side in, side out | ||||||||
| FD |
| Vertical installation of food grade | ||||||||
| wetted material | R4 |
| 304 | |||||||
| R6 |
| 316L | ||||||||
| RP |
| 304+PTFE | ||||||||
| Indicator type | Z1 |
| Local indication type | |||||||
| Z2 |
| Two wire remote transmission type | ||||||||
| Z3 |
| 220VRemote transmission type | ||||||||
| Z4 |
| Battery powered type | ||||||||
| Media Type | L |
| liquid | |||||||
| Q |
| gas | ||||||||
| additional parameters | T |
| Jacket type | |||||||
| G |
| High voltage type | ||||||||
| Y |
| high-temperature type | ||||||||
| Explosion proof type | i |
| Intrinsic safety type | |||||||
| d |
| flameproof type | ||||||||
| alarm method | L |
| Lower limit alarm | |||||||
| H |
| upper limit alarm | ||||||||
| D |
| upper and lower limit alarm | ||||||||
| 口 path |
| DN | ||||||||
For example:SLH1/R4/Z1/L/T/d/L/DN15The meaning is vertical installation with bottom in and top out, and the sensor material is304The indicator type is local indication type, the medium type is liquid, with a jacket, explosion-proof type,Equipped with a lower limit alarm, with a caliber ofDN15.