Mining shield machine cable UGEFHP6/6KV3&# 215; 185+3× thirty-five

NegotiableUpdate on 12/29
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Mining shield tunneling machine cable UGEFHP6/6KV3& #215; 185+3& #215; 35. This product is suitable for high-voltage rubber sheathed flexible cables with ethylene propylene rubber insulation and chloroprene rubber sheath for open-pit mines and underground excavation heavy equipment with rated voltage of 14/25kV and below.
Product Details

Detailed information on mining shield machine cable UGEFHP6/6KV3 × 185+3 × 35:

Mining shield machine cableUGEFHP6/6KV, For shield tunneling machinescable(High voltage rubber sheathed flexible cable for open-pit mining) Product use:

1. Mining shield machine cable UGEFHP6/6KV 3 × 185+3 × 35 Product execution standard: "Shield machine high-voltage rubber sheathed flexible cable"

UGEFHP6/6KV Mining Shield Machine Cable Purpose: This product is suitable for high-voltage rubber sheathed flexible cables with ethylene propylene rubber insulation and chloroprene rubber sheath for open-pit mines and underground excavation heavy equipment with rated voltage of 14/25kV and below.

3 Mining Shield Machine Cable UGEFHP6/6KV 3 × 185+3 × 35 Mining Shield Machine Cable UGEFHP6/6KV Usage Characteristics:

3.1 The maximum rated temperature of the UGEFHP6/6KV3 × 185+3 × 35 cable conductor of the mining shield machine is 90 ℃.

3.2 During a short circuit (with a maximum duration of 5 seconds), the maximum high temperature of the cable conductor shall not exceed 250 ℃.

3.3 Cable allows for the lowest ambient temperature: UGEFP type: -15 ℃; UGEFHP type: -33 ℃.

3.4 The maximum allowable bending radius for cables is 6D when used to fix equipment, 10D when connected in a freely movable manner, 12D when using cable reels for retraction, and 15D when using steering wheels (where D is the cable diameter).

4 Mining Shield Machine Cable UGEFHP6/6KV3 × 120+3 × 25 Model and Name:

model

Rated voltage (Uo/U) kV

name

UGEFP

3.6/6 6/6 6/10 8.7/10 8.7/15 12/20 14/25

Cable for shield tunneling machine (high-voltage rubber sheathed flexible cable for open-pit mining)

GEFHP

3.6/6 6/6 6/10 8.7/10 8.7/15 12/20 14/25

Cold resistant cable for shield tunneling machine (high-voltage cold resistant rubber sheathed flexible cable for open-pit mining)

5 Mining Shield Machine Cable UGEFHP6/6KV 3 × 25+3 × 10 Structural Dimensions and Technical Parameters:

Table 1 High voltage (cold resistant) rubber sheathed flexible cable for open-pit mining 3.6/6kV

Number of cores x nominal cross-section
mm2

Approximate outer diameter of cable
mm

20 ℃ main core insulation resistance
≥MΩ? km

Approximate weight of cable
kg/km

3×25+3×10

48.0-52.0

400

4245

3×35+3×10

51.0-56.0

360

4828

3×50+3×16

56.7-61.7

320

5670

3×70+3×16

61.2-66.2

280

7177

3×95+3×16

67.5-72.5

250

8337

3×120+3×25

70.7-75.7

230

9655

3×150+3×25

75.1-80.1

210

11661

3×185+3×35

81.2-86.2

190

13092

Table 2 High voltage (cold resistant) rubber sheathed flexible cable for open-pit mining 6/6KV 6/10kV

Number of cores x nominal cross-section
area mm2

Approximate outer diameter of cable
mm

20 ℃ main core insulation resistance
≥MΩ? km

Approximate weight of cable
kg/km

3×10+1×10

48.9-52.9

550

3500

3×16+1×16

53.1-58.1

500

3834

3×25+3×10

49.7-54.7

450

4087

3×35+3×10

54.5-59.5

400

4979

3×50+3×16

58.4-63.4

350

5972

3×70+3×16

62.9-67.9

310

7134

3×95+3×16

69.2-74.2

280

8695

3×120+3×25

72.5-77.5

260

10096

3×150+3×25

78.6-83.6

230

11917

3×185+3×35

82.9-87.9

220

13721

Table 3 High voltage (cold resistant) rubber sheathed flexible cable for open-pit mining 8.7/10KV 8.7/15kV

Number of cores x nominal cross-section mm2

Approximate outer diameter of cable
mm

20 ℃ main core insulation resistance
≥MΩ? km

Approximate weight of cable
kg/km

3×16+1×16

58.5-63.5

610

4648

3×25+3×10

56.2-61.2

550

5168

3×35+3×10

59.2-64.2

500

5861

3×50+3×16

63.1-68.1

440

7166

3×70+3×16

69.5-74.5

390

8771

3×95+3×16

74.0-79.0

350

10126

3×120+3×25

79.0-84.0

330

11827

3×150+3×25

83.3-88.3

300

13554

3×185+3×35

87.6-93.6

280

15489