Welcome Customer !

Membership

Help

Hangzhou Double Color Intelligent Testing Instrument Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Hangzhou Double Color Intelligent Testing Instrument Co., Ltd

  • E-mail

    liqindi@hzsszn.com

  • Phone

    13454673196

  • Address

    4th Floor, Building 1, Fuhua Building, Zijin Science and Technology Innovation Park, Hangzhou, Zhejiang

Contact Now

New national standard fire emergency light testing system

NegotiableUpdate on 01/10
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The SS-1000Y new national standard fire emergency light testing system imaging brightness meter is produced by Hangzhou Double Color Intelligent Testing Instrument Co., Ltd. It uses imported components and is equipped with a 4/3-inch 16 megapixel CMOS sensor and a high-precision matching V (λ) filter. The pixel size is 3.45umx3.45um, and the measurement range is 0.01-10000 cd/m& #178; Meet the measurement accuracy standards. The device supports frame exposure and can obtain images through multiple acquisition modes. It can test parameters such as brightness and chromaticity coordinates, and generate brightness distribution curves
Product Details

New national standard fire emergency light testing systemtechnical indicators

SS-1000YNew national standard fire emergency light testing systemImaging brightness meter is applied in lighting research, street light and road brightness testing, light environment testing, classroom lighting, sports stadium lighting, tunnel lighting, display screen surface brightness analysis, etc,The testing project includes the brightness of any point on the image,The function of analyzing parameters such as the average, maximum, minimum, and equal brightness color map of brightness within any range.

Performance parameters:pixel size3.45umx3.45um CMOSsize4/3Inch image sensor and high-precision matchingV(λ)filter;Effective pixels1600Ten thousand, resolution@frame rate4112x4112maximum@23.5fpsADwidth12bit Point matrix,Can capture the entire scene:Simultaneously measure the brightness of each pixel point.

Pixel Capture:Automatic, point, multi-point, multi-point connection, circle, square, polygon, ellipse, curve, etc

Test parameters:1Brightnesscd/m2Color coordinatesxyMaximum value, minimum value, average value, uniformity, brightness distribution curve

Key Features:

1High precision measurement: strict matchingHuman visual functionV(λ)The color filterCan accurately obtain real and accurate brightness data.

2Rich software features: It has functions such as single point, multi-point, and area brightness and chromaticity uniformity distribution pseudo color maps, and each parameter can be set with upper and lower limits for judgment.

3Exposure area: You can set the exposure area to move any pixel size

4Support secondary calibration function

5Rich interfaces: equipped with input and outputIOInterface, compatible with customersPLCWait for automated equipment to trigger testing and output qualified or unqualified results(PASS/NG)Instructions can also be provided for third-party developmentSDKSoftware package.

Main applications:Main applications: testing of brightness in various fields such as point light sources, surface light sources, fire emergency lights, navigation lights, urban lighting, tunnel lights, automotive ambient lights, road brightness, landscape lighting, dashboard brightness, display screen brightness, light sources and light-emitting devices, film and television, traffic signal signs, architecture, and atmospheric lightingLEDTesting of finished lighting fixturesLEDUniformity testing of lighting fixtures, etc.

CIE 117-1995Indoor lighting discomfort and glareCIE 112-1994Glare evaluation system for outdoor sports venues and area lightingCIE 140-2000Road lighting calculation

GB50034-2013Architectural Lighting Design StandardsCJ145-2015Design Standards for Urban Road LightingGB 7793-2010Lighting and Hygiene Standards for Primary and Secondary School ClassroomsJG1153-2016Lighting design and testing standards for sports venues, as well as other glare related standards,

GB4599-2007TheQC/T413Test standards for automotive ambient lightingFire emergency light New National StandardGB17945-2010for automotive use LEDheadlightGB 25991-2010

threePerformance indicators

parameter name

parameter indicators

optics

4/3'

Sensor Model

COMS

camera type

Ycamera

pixel size

3.45umx3.45um

Effective pixels

1600ten thousand

exposure method

Frame exposure

resolution@frame rate

4112x4112maximum@23.5fps

signal-to-noise ratio

40dB

dynamic range

73.6dB

sensitivity

1 146mV

ADwidth

12bit

Output pixel width

12bit

Collection Mode

continuous/soft trigger/Hardware trigger

Maximum gain(multiple)

250

Exposure area

Can be set to move any pixel size

Exposure time range(ms)

0.0141~29546.9

frame buffer

128MB

lens mount

OptionalCSC

data interface

USB3.0

power supply

5V

power

<2W

Overall dimensions

155*131*126mm

weight

500g

measurement range

0.01-10ten thousandcd/m²

measurement accuracy

± 4% reading ± 1 reading) under light source A

Measurement repeatability

±0.1%

focal length

12mm

sensor type

Human visual functionV(λ)Color filter matching