Model:OS700(1-6Combination of gases at will
OS700Introduction to Portable Composite Gas Detector:
OS700Portable composite gas detector is used for rapid detection of various gas concentrations and environmentsTemperature and humidity measurement, if the measurement exceeds the limit, an alarm will be issued.OS700adopt2.5Real time display of high-definition color screen, using internationally renowned brandsGas sensors,The main detection principles include: electrochemistryInfrared, catalytic combustion, thermal conductivityPIDLight ions, etc.Advanced circuit design, mature kernel algorithm processing,Unique exterior design,Obtained multiple software copyrights and design patents.OS700Suitable for detecting gas concentration in pipelines, confined spaces, and atmospheric environments; Gas leakage and high concentration single gas purity with various background gases such as nitrogen or oxygen. Detection types exceed500Other types.

OS700Characteristics of portable composite gas detector:
★Can detect simultaneously1~6Gas species, units can be freely switched
Optional units:PPMThemg/m3TheVol%TheLEL%ThePPHMTheppbThemg/L.
★Built in pump suction measurement, integrated with water vapor and dust filters, fast response, supports long-distance sampling
Built in water vapor and dust filters prevent sensors and instruments from being damaged by water vapor and dust, and can be used in high humidity and high dust environments;
Sampling distance greater than10riceSpecial gas path design, capable of direct detection; Negative pressure or positive pressure-0.5Gas weighing around 2 kilograms has no impact on the measurement results.
★Rich human-machine interface
2.5Inch high-definition color screen, displaying real-time concentration, alarm, time, temperature, humidity, storage, communication, battery level, charging status, concentration units
Information such as gas molecular formula and gas name; The menu interface uses high-definition simulation graphics to display the function names of each menu.
★Large capacity data storage function, supporting multiple storage methods
standard configuration10Ten thousand data storage capacity, customizable for larger capacities; Support real-time storage, scheduled storage, or only storing alarm concentration data;
Support local viewing and deleting data, and can also be done throughUSBorRS232The interface uploads data to the computer, and the upper computer software analyzes and stores the data
Storage and printing.
★Multiple communication interfaces and printing functions
Infrared communication interface (optional)USBInterfaceRS232Interface, optional external micro wireless infrared printer.
Print content: company name, gas name, date and time, environmental temperature and humidity, concentration data, test results (whether qualified).
★High temperature gas detectionOptional
Optional high temperature sampling and cooling filter handleOr high-temperature and high humidity pretreatment systemcandetection800Smoke with high temperature. Gas detection at higher temperatures can be customized.
★Three display modes can be switched
Simultaneously display four gas concentrations, with large font circulating to display the concentration of a single channel gas, and real-time curve display.
★Graphical display
Reflect the trend of gas concentration changes over a period of time in the form of a curve.
●Data recovery function
You can choose to partially or fully restore, eliminating the worries caused by misoperation.
● Can be set to display maximum, minimum, and average values
●standardUSBCharging, with charging protection function, supportsUSBhot-swapping
Can be charged with a computer or power bank, compatible with mobile phone chargers; There are overcharging, overdischarging, overvoltage Short circuit and overheating protection;5Accurate battery level display;
The detector can work normally during charging.
●adopt5500mALarge capacity rechargeable polymer battery that can work continuously for a long time
●High precision temperature and humidity measurement (optional)
●Support real-time detection or scheduled detection
When not detecting, the pump can be turned off to extend the startup time.
●Multiple alarm methods, with multi-dimensional and three-dimensional indication of alarm status during alarm
Includes sound and light alarms, vibration alarms, and visual alarms on the display screen. The types of alarms include concentration alarm, undervoltage alarm, and fault alarm.
●Multiple alarm mode settings
Low alarm, high alarm, interval alarm, weighted average alarm.
● Misoperation recognition function
Automatic identification and prevention of concentration calibration errors can avoid adverse effects caused by human factors.
●Zero point automatic tracking, long-term use is not affected by zero drift
●Multi level calibration of target points to ensure measurement linearity and accuracy
●Chinese and English interface selectable
● Wide operating temperature:-40~+70℃Support temperature compensation
●log recording
Record calibration logs, maintenance logs, fault records, fault resolution measures, sensor life expiration reminder, and next concentration calibration time reminder function.
●Meet the requirements of intrinsic safety circuit design, anti-static, anti electromagnetic interference, pass national standard testing andCMCCertification of Production License for Measuring Instruments
●Protection level up toIP66Waterproof, dustproof, explosion-proof, and shockproof
OS700Technical parameters of portable composite gas detector:
gas detection |
composite gasOptional: Can detect any 1-5 gas concentrations and temperature/humidity |
|||||||
Testing Scope |
Refer to the attached table |
|||||||
resolution |
Refer to the attached table |
|||||||
Detection Principle |
Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, etc., depending on gas, range, on-site environment, and user requirements. |
|||||||
sensor lifespan |
Electrochemical principle takes 2-3 years, oxygen can be used for 2 or 6 years, infrared principle takes 5-10 years, chemical combustion takes 3 years, and thermal conductivity takes 5 years. |
|||||||
Detection method |
Built in pump suction, flow rate500milliliter/minute |
|||||||
display mode |
2.5inch320X240High definition color screen display, eightButton operation |
|||||||
detection accuracy |
≤± 2% F.S (higher precision can be customized) |
|||||||
Linearity |
≤±2% |
repetitiveness |
≤±2% |
|||||
alarm method |
Sound and light alarm, vibration alarm, visual alarm, sound and light alarm+vibration+Visual alarm, turn off alarm |
|||||||
response time |
T90≤20second |
recovery time |
≤30second |
|||||
working power supply |
DC3.6V |
|||||||
battery capacity |
3.6VDC,5000mALarge capacity rechargeable polymer battery,Equipped with overcharge, overdischarge, overvoltage, overheating, and short circuit protection functions |
|||||||
Usage environment |
temperature-40℃~+70℃Relative humidity ≤0-99%RH(Built in filter can be used in high humidity or high dust environments) |
|||||||
Sample gas temperature |
-40℃~+70℃ Optional high temperature sampling and cooling filter handle or high temperature and high humidity pretreatment system for detection 800℃ The concentration of flue gas |
|||||||
temperature measurement |
-40℃~+120℃Accuracy of 0.5 ℃ |
Humidity measurement |
0-100%RHAccuracy 3% RH |
|||||
data storage |
standard configuration10Ten thousand data capacity, customizable for larger capacity, supports local viewing or data export, free upper computer Communication software. The storage function is set to off by default and can be set to on. The storage time interval can be set arbitrarily |
|||||||
communication interface |
USB(Charging and Communication)RS232Infrared communication, automatic recognition |
|||||||
printer |
Optional, external micro wireless infrared thermal printer |
|||||||
Interface language |
Chinese or English can be set, default Chinese interface |
|||||||
Explosion-proof type |
intrinsically safe |
Explosion-proof marking |
Explosion proof Exd Ⅱ CT6 |
|||||
Protection level |
IP66Rain and water splashes, dust prevention |
|||||||
Overall dimensions |
180×78×33mm(L×W×H) |
Weight |
350g |
|||||
Standard Appendix |
Instruction manual, certificate of conformity, warranty cardUSBCharger (including data cable), high-end aluminum alloy instrument box |
|||||||
Optional accessories |
1.2 mScalable sampling handle (standard is1rice)Temperature and humidity measurement function, high temperature sampling and cooling filter handle, CD (upper computer communication software), crocodile clip, humidity dust filter, high temperature and high humidity pretreatment system, multiple humidity dust filters, hanging rope, external micro wireless infrared printer |
|||||||
Application scenarios |
All occasions requiring gas concentration detection, such as petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, air treatment, etc |
|||||||