Online pure water pH analyzer, using high-quality chip components with surface mount technology; Adopting microprocessors, intelligent networking, and menu based operations; Equipped with functions such as isolated output current, relay output, and communication interface; Configure various pH electrodes for online continuous measurement and control. Widely used in water industries such as power plants and thermal power plants, it is also suitable for high-purity water, pure water, etc.
Product Details

Measurement principle:

The pH sensor is based on the ion selective electrode method. The principle is to use a membrane electrode to represent the concentration of the measured ion as the electrode potential value, and determine the ion concentration in the solution by measuring the electrode potential. Specifically, two different electrodes are inserted into the tested solution, and the potential changes with the concentration of hydrogen ions, which is called the working electrode; The other electrode has a fixed potential and is called the reference electrode. These two electrodes form a primary cell, and the potential between the two electrodes is measured to determine the pH value of the measured solution according to the Nernst equation.

Technical Specifications:

(1) Measurement range: pH: 0-14.00pH; ORP: -1999~+1999mV (instrument pH/ORP compatible)

Temperature: -10~100 ℃

(2) Basic error: pH: ± 0.01pH; ORP: ± 2mV;

Temperature: ± 0.8 ℃.

(3) Stability: pH: ≤ 0.02pH/24h; ORP:≤3mV/24h。

(4) Electronic unit output current error: ± 0.1mA.

(5) Electronic unit output current: 0-10mA or 4-20mA.

(6) Electronic unit alarm error: ± 0.1% F · S.

(7) Two sets of relay contacts: 3A/240VAC; 6A/28VDC or 120VAC.

(8) Power supply: AC: 200-265V/50-60Hz; DC: 24V (DC ordering requires declaration).

(9) Power consumption: ≤ 3W.

(10) Electronic unit weight (base type): approximately 600g.

(11) Electrode withstand water sample pressure: ≤ 0.6MPa.

(12) Electronic unit basic dimensions: 96 (length) x 96 (width) x 125 (depth) mm.

(13) Electronic unit basic installation hole size: 91 × 91mm.

(14) A pH meter is equipped with a pH electrode, and the type of pH electrode is configured according to the requirements of the measured medium.

Use ORP electrode as ORP meter to measure the mV value corresponding to pH.

(15) Electrode installation method: installation, inlet and outlet pipe connection: use hard or soft pipes.

The outer diameter of the hard tube is Ø 10 or a flexible hose with an inner diameter of Ø 8 is connected to it; Determine the installation method according to the on-site requirements

(16) Working conditions: Environmental temperature: -10~45 ℃; Relative humidity: not exceeding 90%.

Functional features:

  • Intelligent type: using a single-chip microprocessor to complete pH or mV value measurement and temperature measurement.

  • Human computer dialogue interface: menu operation structure, users can operate according to the prompts on the screen.

  • Networked: capable of remote transmission, monitoring, and control.

  • Isolation output current: The software selects either 0-10mA or 4-20mA output.

  • Measurement range: The upper and lower limit parameters can be freely set corresponding to the output current.

  • The upper and lower limit over limit alarms can be set arbitrarily, and over limit alarms will flash to indicate the measurement status.

  • Two sets of relay control, adjustable hysteresis, can be connected to external control equipment such as metering pumps and solenoid valves, and implement automatic dosing control. ※ Self set password, users can set or modify their own password to prevent unauthorized personnel from entering and causing misoperation; And it can help you retrieve your forgotten instrument password; We also provide users with contact information for technical consultation and after-sales service.

  • It has multiple calibration functions including one point calibration, two-point calibration, and known concentration calibration; Correction functions such as measurement errors.

  • According to the user's order statement, RS485//RS232 communication interface (communication protocol CD provided) can be provided.

  • According to the user's order statement, a 24VDC power supply can be provided.

  • According to the user's project requirements for export abroad, the ordering statement can provide: English version including software menu, operation panel, manual, etc. of the instrument.




Similar Product Recommend