Paper recorder SIN-R1000F

NegotiableUpdate on 07/29
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The SIN-1000F sterilization recorder uses a special thermal printing recording method and advanced microprocessor control technology to achieve high recording clarity, receive thermal resistance Pt100 signals, and can record scale values, time, and the curve of each signal in real time on a 100mm wide paper grid printed by itself. The channel number is printed next to the trajectory of each channel. Alarm control values, system error correction, recording ruler, data printing interval, paper feed speed, printing depth and time parameters can be set through the keyboard, and the set parameters can be protected.

Product Details

The SIN-1000 paper recorder adopts an imported fixed thermal head for printing and recording functions, with no ink consumption, no pen position error, and anti vibration. remember

The recorder is a universal signal input that can record all on-site signals such as temperature, temperature and humidity, current, voltage, pressure, flow rate, liquid level, etc.

The SIN-1000 paper recorder is currently widely used in industries and research institutions such as metallurgy, pharmaceuticals, petroleum, chemical, power, and electricity.

The combination of recorder and on-site instruments:

1. Install a flow meter to measure and record on-site flow signals.

2. Equipped with a pressure transmitter to measure and record pressure signals on site.

3. Equipped with temperature sensors to measure and record temperature signals on site.

4. Distribution quantity transmitter, capable of measuring and recording on-site electrical signals.

5. Equipped with a liquid level transmitter to measure and record on-site liquid level signals.

6. Install a temperature and humidity transmitter to measure and record temperature and humidity signals on site.

Number of channels: 8 universal signal inputs.

Input signal: Type II standard signal: (0~10) mA, (0~5) V.

Type III standard signal: (4~20) mA, (1~5) V.

6 types of thermocouples: B, E, J, K, S, T.

3 types of thermal resistors: Pt100, Cu50, Cu100.

Other non-standard signals: (0-20) mV, (0-50) mV, (0-100) mV.

Alarm output: Relay contact capacity: 24VDC, 3A; 220VAC, 3A

Provide six sets of relay contact outputs for users to use in any combination

Each channel alarm can select upper limit, lower limit, difference upper limit, and difference lower limit

The alarm hysteresis of each channel can be set, and there is an indicator light to prompt when the relay is activated

Record: There are 800 hot stamping points within a range of 100mm

Trend and numerical recording of measured values

Print the ruler scale and each channel mark while recording the curve

Print the scale value, current time, and paper feed speed every 100mm

Adopting imported fixed thermal head, no ink consumption, no pen position error, anti vibration

Display: Alarm prompt and indicator light

Fixed point or cyclic display of measured values

Set parameter display [in set state]

Time display [when all input signals are turned off]

Channel isolation: Input channels are isolated from each other without interference.

Sampling period: 0.6 seconds, which means that each channel is sampled once every 0.6 seconds

Recording paper: Made of Japanese king paper, it can store data for up to 5 years.

Power supply: AC power supply voltage: 220V AC; Frequency: 50Hz.

Paper speed: The paper speed ranges from 10 mm/h to 9990mm/h, and can be set freely through the keyboard.

Dimensions: External dimensions 144mm × 144mm × 245mm, opening dimensions 138+1-0mm × 138+1-0mm

Kind reminder: This product is suitable for non explosion proof occasions. If explosion-proof products are required, special instructions should be provided