Welcome Customer !

Membership

Help

Shenzhen Anpar Technology Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Pathfinder Online Fixed Dichlorobenzene Detector with Display Series Network Version

NegotiableUpdate on 01/30
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Pathfinder online fixed dichlorobenzene detector with display series network version is the most basic one in the Pathfinder series of fixed dichlorobenzene detectors. The main functions include real-time display of on-site concentration detection, signal transmission, LED lights and relay alarm functions, and built-in WIFI module. Due to the built-in WIFI module of the instrument, if users encounter problems during on-site use, they need the manufacturer's assistance. They can use the on-site mobile WIFI, Ampal's handheld gas detector WIFI, and the on-site WIFI to connect with Ampal's server. Facilitate remote performance testing and maintenance of the detector by the manufacturer. The Pathfinder online fixed dichlorobenzene detector with display series network version has 2 sets of relays (switch signals) inside, which can control equipment such as fans, sound and light alarms, solenoid valves, etc. ...
Product Details

Pathfinder Online Fixed DichlorideBenzene detectorIntroduction to the Network Edition with Display Series

The Pathfinder online fixed dichlorobenzene detector with display series network version is the most basic one in the Pathfinder series of fixed dichlorobenzene detectors. The main functions include real-time display of on-site concentration detection, signal transmission, LED lights and relay alarm functions, and built-in WIFI module. Due to the built-in WIFI module of the instrument, if users encounter problems during on-site use, they need the manufacturer's assistance. They can use the on-site mobile WIFIAnparThe company's handheldGas detectorWIFI、 The on-site WIFI is connected to the Ampar server. Facilitate remote performance testing and maintenance of the detector by the manufacturer. The Pathfinder online fixed dichlorobenzene detector with display series network version has 2 sets of relays (switch signals) inside, which can control equipment such as fans, sound and light alarms, solenoid valves, etc.

Product Features

★ Built in WIFI module, which can achieve wireless signal transmission in areas with WIFI signal coverage;

★ Internet of Things function: It can connect to Ampar servers to achieve remote data monitoring, alarm reminders, alarm value settings, remote after-sales service, etc. for mobile phones and computers;

Equipped with third-generation "COVER" series sensor modules, some of which have temperature and humidity monitoring and compensation functions;

★ Industrial grade EMC module to cope with harsh on-site environmental interference;

★ Ultra high definition color display screen. Long distance visibility, with a visual distance of 10 meters (5.0 visual acuity);

★ Bilingual operating system: capable of switching between Chinese and English systems;

★ Black box function: operation and alarm records, over temperature usage records, over humidity usage records, over range usage records;

★ Complete reminder and alarm functions: sensor expiration reminder function, over concentration alarm function, over temperature and humidity alarm function, fault alarm function, instrument calibration reminder function, etc;

★ Explosion proof design, intrinsic safety design, RoHS design;

★ Fast detection speed: The Pathfinder online fixed dichlorobenzene detector with display series network version has a fast detection speed compared to similar products in the same industry;

★ Operation guide: Humanized design, with operation instructions for each function setting to prevent customer misoperation, unique in the industry;

★ Zero point automatic calibration: For certain environmental applications, the instrument can achieve zero point automatic calibration function;

Technical Parameter

Project Content Specific parameters
product name Pathfinder Online Fixed Dichlorobenzene Detector with Display Series Network Version
product name Para dichlorobenzene gas transmitter, para dichlorobenzene gas probe, para dichlorobenzene gas sensor
2-chlorobenzene gas detector, dichlorobenzene gas analyzer, dichlorobenzene gas detector
Detect gas For dichlorobenzene and other gases, please consult the manufacturer or refer to the attached table
measuring range Based on the on-site situation, please consult the manufacturer for details
Display units Ppm, mg/m3, ppb, pphm,% VOL,% LEL (partially switchable)
Resolution Determined by the detection range
Accuracy ≤± 3% FS (normal accuracy); ≤± 1% FS (high precision)
Repeatability ≤±1%
response time T90 is determined by sensor characteristics
recovery time T90-T10 determined by sensor characteristics
Display mode 320 * 240 high-definition color screen 2.0 inches
Visible distance ≥ 10 meters (5.0 visual acuity)
system language Chinese (default) and English are switchable
operating mode Infrared remote control, buttons (cover opening), remote network (such as mobile app or upper computer software)
detection Diffusion type
Installation method Wall mounted (wall mounted), pole mounted (horizontal or vertical). For more information, please consult the manufacturer
Shell material Subject: Alloy (anti-corrosion and anti-oxidation surface treatment). Probe: anti-corrosion alloy or 316L stainless steel
Explosion proof sign Dual explosion-proof standards Exd Ⅱ CT6 and Ex Td A21
protection grade IP66
Working temperature -40 ℃~70 ℃ (ordinary catalytic combustion principle sensor)
-40 ℃~270 ℃ (special catalytic combustion)
-40 ℃~50 ℃ (electrochemical)
-20 ℃~50 ℃ (PID principle sensor)
-20 ℃~50 ℃ (infrared/fluorescence gas sensor)
-40 ℃~70 ℃ (thermal conductivity principle sensor)
-40 ℃~420 ℃ (Zirconia principle oxygen sensor)
Working humidity 10%~95%RH, No condensation (humidity>90% RH, optional filter for condensation)
Working pressure 0.08~0.6MPa (thermal conductivity principle sensor)
0.02-0.36MPa (Zirconia principle oxygen sensor)
86-106KPa (Other)
Temperature measurement range -40 ℃~+120 ℃ accuracy ± 1 ℃ (with temperature compensation function)
Humidity detection range 0-100%RH, Accuracy ± 3% (with humidity compensation function)
output signal Three wire system 4-20mA+RS-485+wireless WIFI+2 relay (switch quantity)
Voltage 0-5/10V+RS-485+wireless WIFI+2 relay (switch quantity)
RS-422+wireless WIFI+2 relays (switch quantity)
Frequency signal (adjustable)+wireless WIFI+2 relays (switch quantity)
Three wire Hart+wireless WIFI+2 relay (switch quantity)
CAN bus+wireless WIFI+2 relays (switch quantity)

Note: Relay (switch quantity) specification: Output 2A@30VDC perhaps 0.6A@125VAC
power consumption Electrochemical sensor: P ≤± 2.5W
Conventional catalytic sensing: P ≤± 3.9W
Low power catalytic sensor: P ≤± 2.8W
Thermal conductivity sensor: P ≤± 2.9W
Infrared sensor: P ≤± 2.9W
PID sensor: P ≤± 2.8W
Alarm method Panel LED alarm;
Display screen character flashing and information reminder
Dual relay output;
control output Fan, valve, sound and light alarm
Protection function Lightning and surge protection design, intermittent detection, sensor automatic protection function (optional)
service life 2 years (sensors), 5 years (instruments)
Power supply 12-35VDC, Typical power supply 24VDC
size Overall dimensions: 189 * 92 * 94mm (length * width * thickness) - Pathfinder series basic model
Wiring port size: Internal thread M20 * 1.5 (G1/2 internal thread, G3/4 internal thread
1/2NPT internal thread, NPT3/4NPT internal thread are optional);
weight ≥1.55kg
Product Certification Fire certification (mandatory CCCF)
Measurement Certification CMC
ATEX
CE
RoHS
Third party metrology certification
National Patent Product Certification
Three system certifications: ISO9001, ISO14001, ISO18001
Execution standards GB 15322.1-2003, GB 3836.1-2010,
GB 3836.2-2010, GB 3836.4-2010,
GB 12476.1-2013, GB 12476.4-2010,
GB 12476.5-2 013,
JJF 1363-2012, JJF 1368-2012,
JJF 1421-2013, JJF 1364-2012
Standard accessory Packaging box, instruction manual, certificate of conformity, warranty card, remote control (included), factory inspection report
Installation bracket (optional), calibration cover (optional)