Pathfinder online fixed p-nitrochlorineBenzene detectorIntroduction to the Network Edition with Display Series
The Pathfinder online fixed p-nitrochlorobenzene detector with display series network version is the most basic one in the Pathfinder series of fixed p-nitrochlorobenzene detectors. The main functions include real-time display of on-site concentration detection, signal transmission, LED lights and relay alarm functions, and built-in WIFI module. Due to the built-in WIFI module of the instrument, if users encounter problems during on-site use, they need the manufacturer's assistance. They can use the on-site mobile WIFIAnparThe company's handheldGas detectorWIFI、 The on-site WIFI is connected to the Ampar server. Facilitate remote performance testing and maintenance of the detector by the manufacturer. The Pathfinder online fixed type p-nitrochlorobenzene detector with display series network version has 2 sets of relays (switch signals) inside, which can control equipment such as fans, sound and light alarms, solenoid valves, etc.
Product Features
★ Built in WIFI module, which can achieve wireless signal transmission in areas with WIFI signal coverage;
★ Internet of Things function: It can connect to Ampar servers to achieve remote data monitoring, alarm reminders, alarm value settings, remote after-sales service, etc. for mobile phones and computers;
Equipped with third-generation "COVER" series sensor modules, some of which have temperature and humidity monitoring and compensation functions;
★ Industrial grade EMC module to cope with harsh on-site environmental interference;
★ Ultra high definition color display screen. Long distance visibility, with a visual distance of 10 meters (5.0 visual acuity);
★ Bilingual operating system: capable of switching between Chinese and English systems;
★ Black box function: operation and alarm records, over temperature usage records, over humidity usage records, over range usage records;
★ Complete reminder and alarm functions: sensor expiration reminder function, over concentration alarm function, over temperature and humidity alarm function, fault alarm function, instrument calibration reminder function, etc;
★ Explosion proof design, intrinsic safety design, RoHS design;
★ Fast detection speed: The Pathfinder online fixed p-nitrochlorobenzene detector with display series network version has a fast detection speed compared to similar products in the same industry;
★ Operation guide: Humanized design, with operation instructions for each function setting to prevent customer misoperation, unique in the industry;
★ Zero point automatic calibration: For certain environmental applications, the instrument can achieve zero point automatic calibration function;
Technical Parameter
| Project Content | Specific parameters |
| product name | Pathfinder online fixed p-nitrochlorobenzene detector with display series network version |
| product name | P-nitrochlorobenzene gas transmitter, p-nitrochlorobenzene gas probe, p-nitrochlorobenzene gas sensor P-nitrochlorobenzene gas detector, p-nitrochlorobenzene gas analyzer, p-nitrochlorobenzene gas detector |
| Detect gas | For nitrochlorobenzene and other gases, please consult the manufacturer or refer to the attached table |
| measuring range | Based on the on-site situation, please consult the manufacturer for details |
| Display units | Ppm, mg/m3, ppb, pphm,% VOL,% LEL (partially switchable) |
| Resolution | Determined by the detection range |
| Accuracy | ≤± 3% FS (normal accuracy); ≤± 1% FS (high precision) |
| Repeatability | ≤±1% |
| response time | T90 is determined by sensor characteristics |
| recovery time | T90-T10 determined by sensor characteristics |
| Display mode | 320 * 240 high-definition color screen 2.0 inches |
| Visible distance | ≥ 10 meters (5.0 visual acuity) |
| system language | Chinese (default) and English are switchable |
| operating mode | Infrared remote control, buttons (cover opening), remote network (such as mobile app or upper computer software) |
| detection | Diffusion type |
| Installation method | Wall mounted (wall mounted), pole mounted (horizontal or vertical). For more information, please consult the manufacturer |
| Shell material | Subject: Alloy (anti-corrosion and anti-oxidation surface treatment). Probe: anti-corrosion alloy or 316L stainless steel |
| Explosion proof sign | Dual explosion-proof standards Exd Ⅱ CT6 and Ex Td A21 |
| protection grade | IP66 |
| Working temperature | -40 ℃~70 ℃ (ordinary catalytic combustion principle sensor) -40 ℃~270 ℃ (special catalytic combustion) -40 ℃~50 ℃ (electrochemical) -20 ℃~50 ℃ (PID principle sensor) -20 ℃~50 ℃ (infrared/fluorescence gas sensor) -40 ℃~70 ℃ (thermal conductivity principle sensor) -40 ℃~420 ℃ (Zirconia principle oxygen sensor) |
| Working humidity | 10%~95%RH, No condensation (humidity>90% RH, optional filter for condensation) |
| Working pressure | 0.08~0.6MPa (thermal conductivity principle sensor) 0.02-0.36MPa (Zirconia principle oxygen sensor) 86-106KPa (Other) |
| Temperature measurement range | -40 ℃~+120 ℃ accuracy ± 1 ℃ (with temperature compensation function) |
| Humidity detection range | 0-100%RH, Accuracy ± 3% (with humidity compensation function) |
| output signal |
Three wire system 4-20mA+RS-485+wireless WIFI+2 relay (switch quantity) Voltage 0-5/10V+RS-485+wireless WIFI+2 relay (switch quantity) RS-422+wireless WIFI+2 relays (switch quantity) Frequency signal (adjustable)+wireless WIFI+2 relays (switch quantity) Three wire Hart+wireless WIFI+2 relay (switch quantity) CAN bus+wireless WIFI+2 relays (switch quantity) Note: Relay (switch quantity) specification: Output 2A@30VDC perhaps 0.6A@125VAC |
| power consumption | Electrochemical sensor: P ≤± 2.5W Conventional catalytic sensing: P ≤± 3.9W Low power catalytic sensor: P ≤± 2.8W Thermal conductivity sensor: P ≤± 2.9W Infrared sensor: P ≤± 2.9W PID sensor: P ≤± 2.8W |
| Alarm method | Panel LED alarm; Display screen character flashing and information reminder Dual relay output; |
| control output | Fan, valve, sound and light alarm |
| Protection function | Lightning and surge protection design, intermittent detection, sensor automatic protection function (optional) |
| service life | 2 years (sensors), 5 years (instruments) |
| Power supply | 12-35VDC, Typical power supply 24VDC |
| size | Overall dimensions: 189 * 92 * 94mm (length * width * thickness) - Pathfinder series basic model Wiring port size: Internal thread M20 * 1.5 (G1/2 internal thread, G3/4 internal thread 1/2NPT internal thread, NPT3/4NPT internal thread are optional); |
| weight | ≥1.55kg |
| Product Certification | Fire certification (mandatory CCCF) Measurement Certification CMC ATEX CE RoHS Third party metrology certification National Patent Product Certification Three system certifications: ISO9001, ISO14001, ISO18001 |
| Execution standards | GB 15322.1-2003, GB 3836.1-2010, GB 3836.2-2010, GB 3836.4-2010, GB 12476.1-2013, GB 12476.4-2010, GB 12476.5-2 013, JJF 1363-2012, JJF 1368-2012, JJF 1421-2013, JJF 1364-2012 |
| Standard accessory | Packaging box, instruction manual, certificate of conformity, warranty card, remote control (included), factory inspection report Installation bracket (optional), calibration cover (optional) |