E-mail
zhangjing_shuowei@163.com
-
Phone
17721451832
-
Address
Room 1502, Shihong Jinyuan Center, No. 28 Yuanwen Road, Minhang District, Shanghai
Shanghai Shuowei Measurement and Control Technology Co., Ltd
zhangjing_shuowei@163.com
17721451832
Room 1502, Shihong Jinyuan Center, No. 28 Yuanwen Road, Minhang District, Shanghai
Pipe section ultrasonic flowmeter
Siemens ultrasonic heat meter energy meter flow meter, battery or grid powered ultrasonic flow meter is used for regional heating, cooling systems and public works.
The dual channel flowmeter SITRANS FUS380 is powered by batteries or AC power. It can measure water flow in regional heating equipment, local area networks, heat source plants, heat exchange stations, refrigeration equipment, and other conventional water applications.
The SITRANS FUS380 instrument complies with the thermal measurement standards EN 1434, Level 2 and OIMLR752, and the measurement parameters are not affected by operation. The certified flowmeter is named SITRANS FUE380.
The SITRANS FUS380 and SITRANS FUE380 instruments have the same process technology.
By combining with an energy integrator and a pair of temperature sensors, SITRANS FUE380 is part of the energy metering system. For this purpose, Siemens provides the energy integrator SITRANS FUE950.
Pipe section ultrasonic flowmeteradvantage
• Battery powered for 6 years
In the event of communication power failure, optional battery backup is available
Quick measurement frequency 20Hz/0.5Hz (230VAC/battery)
Single key operation, direct display
The principle of dual channel measurement can achieve accuracy
• Integrated or detachable installation
• Can measure any water quality and have no conductivity requirements
• No pressure loss
• Long term stability
Digital output optoelectronic isolation, convenient for connecting to the integrator
Two cumulative pulse outputs
• Dynamic measurement range: up to 1:400
MID certification
Technical parameters:
| Nominal diameter (DN, welded type) | DN50-DN1200 |
| pressure rating | PN16,PN25,PN40 |
| pipeline material | DN50-DN80 brass, DN100-DN1200 carbon steel |
| Material of transducer | Stainless steel AISI316 |
| Medium temperature range | Integrated: 2 ℃~120 ℃; Split type: 2 ℃~200 ℃; |
| cable length | The farthest distance between the signal converter and the sensor is 30m |
| Protection level | IP67 |
| Transmitter environmental temperature | 0~60℃ |
| Material of transmitter | Glass fiber reinforced polyamide |
| power supply method | Powered by batteries or power sources (including battery backup) |
| contact method | pulse |
| certification | EN1434 and OIMLR75Class2, MID |