OS50TSeries portable portable composite gas analyzer features:
★Can simultaneously detect 1-6Gas type, expandable to 18Gas species, units can be freely switched
Units available: PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/L.
型号可选: OS50T-II、OS50T-III、OS50-T-IV、OS50T-V、OS50T-VI、OS50T-VII、OS50T-VII、OS50T-VIII、OS50T-IX、OS50T-X 等
★Built in pump suction measurement, integrated with water vapor and dust filters, fast response, supports long-distance sampling
Built in water vapor and dust filters prevent sensors and instruments from being damaged by water vapor and dust, and can be used in high humidity and high dust environments;
Sampling distance greater than 10 meters, special gas path design, can be directly detected; Negative or positive pressure of 0.5 to 2 kilograms of gas has no effect on the measurement results.
★Rich human-machine interface
3.5-inch high-definition color screen, displaying real-time concentration, alarm, time, temperature, humidity, storage, communication, battery level, charging status, concentration units
Information such as gas molecular formula and gas name; The menu interface uses high-definition simulation graphics to display the function names of each menu.
★Large capacity data storage function, supporting multiple storage methods
Standard 100000 data storage capacity, larger capacity can be customized; Optional USB or SD card storage function, supporting real-time storage, scheduled storage, or only storing alarm concentration data; support
Data can be viewed and deleted locally, or uploaded to a computer via USB, infrared communication, or RS232 interface,
Analyze data and store and print it using upper computer software. Support remote wireless transmission (optional function).
★Multiple communication interfaces and printing functions
Infrared communication interface (optional), USB interface, RS232 interface automatic recognition, optional built-in or external wireless infrared printer.
Print content: company name, gas name, date and time, environmental temperature and humidity, concentration data, test results (whether qualified).
★High temperature gas detectionOptional
Optional high-temperature sampling and cooling filter handle or high-temperature and high humidity pretreatment system can detect flue gas at a temperature of 1300 degrees. Gas detection at higher temperatures can be customized.
★Three display modes can be switched
Simultaneously display four gas concentrations, with large font circulating to display the concentration of a single channel gas, and real-time curve display.
★Graphical display
Reflect the trend of gas concentration changes over a period of time in the form of a curve.
★Infrared remote control
Standard infrared remote control, with one click operation through the infrared remote control function keys, such as modifying alarm points, concentration calibration, zero calibration, and eliminating
Sound, factory reset, enter menu, view records, 4mA output, 20mA output (this function is required for calibrating other acquisition devices).
●Data recovery function
You can choose to partially or fully restore, eliminating the worries caused by misoperation.
● Can be set to display the maximum value, minimum value, and average value
●standardUSBCharging, with charging protection function, supports USBhot-swapping
Can be charged with a computer or power bank, compatible with mobile phone chargers; Has overcharge, overdischarge, overvoltage, short circuit, and overheating protection; 5-level precise power display;
The detector can work normally during charging.
●Adopting through10000mALarge capacity rechargeable polymer battery that can work continuously for a long time
●High precision temperature and humidity measurement (optional)
●Support real-time detection or scheduled detection
When not detecting, the pump can be turned off to extend the startup time.
●Multiple alarm methods, with multi-dimensional and three-dimensional indication of alarm status during alarm
Includes sound and light alarms, vibration alarms, and visual alarms on the display screen. The types of alarms include concentration alarm, undervoltage alarm, and fault alarm.
●Multiple alarm mode settings
Low alarm, high alarm, interval alarm, weighted average alarm.
● Misoperation recognition function
Automatic identification and prevention of concentration calibration errors can avoid operational errors caused by human factors.
●Zero point automatic tracking, long-term use is not affected by zero drift
●Multi level calibration of target points to ensure measurement linearity and accuracy
●Chinese and English interface selectable
● Wide operating temperature: -40 ° C~+70℃, supports temperature compensation
●log recording
Record calibration logs, maintenance logs, fault records, fault resolution measures, sensor life expiration reminder, and next concentration calibration time reminder function.
●Meet the requirements of intrinsic safety circuit design, anti-static, anti electromagnetic interference, pass national standard testing andCMCCertification of Production License for Measuring Instruments
●Protection level up toIP66Waterproof, dustproof, explosion-proof, and shockproof
OS50TSeries portable portable composite gas analyzerTechnical Specifications:
gas detection |
composite gasOptional: Can simultaneously detect any 1~6Gas concentration and temperature/humidity can be expanded to 18 different gases |
|||||||||
Testing Scope |
Refer to the attached table |
|||||||||
resolution |
Refer to the attached table |
|||||||||
Detection Principle |
Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, etc., depending on gas, range, on-site environment, and user requirements. |
|||||||||
sensor lifespan |
Electrochemical principle takes 2-3 years, oxygen can be used for 2 or 6 years, infrared principle takes 5-10 years, chemical combustion takes 3 years, and thermal conductivity takes 5 years. |
|||||||||
Detection method |
Built in pump suction, flow rate800milliliter/minute |
|||||||||
display mode |
3.5inch320X240Large screen high-definition color display with high resolution |
|||||||||
detection accuracy |
≤± 2% F.S (higher precision can be customized) |
uncertainty |
≤±2% |
|||||||
Linearity |
≤±2% |
repetitiveness |
≤±2% |
|||||||
alarm method |
Sound and light alarm, visual alarm, sound and light alarm+Visual alarm, turn off alarm |
|||||||||
response time |
T90≤20second |
recovery time |
≤30second |
|||||||
working power supply |
DC3.6V |
|||||||||
battery capacity |
3.6VDC,10000mARechargeable polymer battery,Equipped with overcharge, overdischarge, overvoltage, and short-circuit protection functions |
|||||||||
Usage environment |
temperature-40℃~+70℃; Relative humidity ≤0-99%RH |
|||||||||
Sample gas temperature |
-40℃~+70℃ Optional high temperature sampling and cooling filter handle or high temperature and high humidity pretreatment system for detection1300The concentration of flue gas at ℃ |
|||||||||
Temperature measurement (optional) |
-40℃~+120 ℃ accuracy 0.5 ℃ |
Humidity measurement |
0-100%RHAccuracy 3% RH |
|||||||
data storage |
standard capacity10Ten thousand pieces of data, optionalCFCardUDisk storage, unlimited capacity, supports local viewing, deletion, or data export, Free upper computer communication software, storage function defaults to off state, can be set to on state, storage time interval can be set arbitrarily |
|||||||||
communication interface |
InfraredUSBTheRS232automatic recognition |
|||||||||
printer |
Optional, built-in micro printer or external micro wireless infrared printer |
|||||||||
Interface language |
Chinese or English can be set, default Chinese interface |
|||||||||
Explosion-proof type |
intrinsically safe |
Explosion-proof marking |
Explosion proof Exd Ⅱ CT6 |
|||||||
Protection level |
IP66Rain and water splashes, dust prevention |
|||||||||
Overall dimensions |
230×210×120mm(L×H×W) |
Weight |
2.5Kg |
|||||||
Standard Appendix |
Instruction manual, certificate of conformityUSBCharger (including data cable), aluminum alloy instrument box40cmStainless steel sampling handle(1Rice hose) |
|||||||||
Optional accessories |
Built in micro printer, external micro wireless infrared printer, temperature and humidity measurement functionUDisk storage, wireless data communication function High temperature sampling and cooling filter handle, high temperature and high humidity pretreatment system, external remote sampling pump, multiple humidity and dust filters1.2 mScalable sampling handle(1Rice hose), CD (upper computer communication software) |
|||||||||
Application scenarios |
All occasions requiring gas concentration detection, such as petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, air treatment, etc |
|||||||||
Common Gas Appendix:OS50TSeries portable portable composite gas analyzer
Common Gas Appendix:
gas detection |
range (Other ranges can be customized) |
precision (更高精度可定制) |
resolution (Higher resolution can be customized) |
response time |
flammable gas(EX) |
0-100%LEL |
<±2%(F.S) |
0.1%LEL |
≤10second |
flammable gas(EX) |
0-100%Vol |
<±2%(F.S) |
0.1%Vol |
≤10second |
methane(CH4) |
0-100%LEL |
<±2%(F.S) |
0.1%LEL |
≤5second |
methane(CH4) |
0-100%Vol |
<±2%(F.S) |
0.1%Vol |
≤10second |
oxygen(O2) |
0-30%/100%Vol |
<±2%(F.S) |
0.01%Vol |
≤15second |
carbon monoxide(CO) |
0-500/1000/2000ppm |
<±2%(F.S) |
0.1ppm |
≤20second |
carbon monoxide(CO) |
0-20000/100000ppm |
<±2%(F.S) |
1ppm |
≤20second |
carbon dioxide(CO2) |
0-2000/5000ppm |
<±2%(F.S) |
1ppm |
≤20second |
carbon dioxide(CO2) |
<±2%(F.S) |
1ppm |
≤20second |
|
carbon dioxide(CO2) |
0-10000/50000ppm |
<±2%(F.S) |
1ppm |
≤20second |
carbon dioxide(CO2) |
0-20/50/100%Vol |
<±2%(F.S) |
0.01%Vol |
≤20second |
formaldehyde(CH2O) |
0-10/50ppm |
<±2%(F.S) |
0.001/0.01ppm |
≤20second |
formaldehyde(CH2O) |
0-1000ppm |
<±2%(F.S) |
0.1ppm |
≤20second |
ozone(O3) |
0-1ppm |
<±2%(F.S) |
0.001ppm |
≤20second |
ozone(O3) |
0-10/50/100ppm |
<±2%(F.S) |
0.01ppm |
≤20second |
ozone(O3) |
0-2000ppm |
<±2%(F.S) |
0.1ppm |
≤20second |
hydrogen sulfide(H2S) |
0-10ppm |
<±2%(F.S) |
0.001ppm |
≤20second |
hydrogen sulfide(H2S) |
0-50/100ppm |
<±2%(F.S) |
0.01ppm |
≤20second |
hydrogen sulfide(H2S) |
0-200/1000/2000ppm |
<±2%(F.S) |
0.1ppm |
≤20second |
sulfur dioxide(SO2) |
0-10ppm |
<±2%(F.S) |
0.001ppm |
≤20second |
sulfur dioxide(SO2) |
0-20ppm |
<±2%(F.S) |
0.01ppm |
≤20second |
sulfur dioxide(SO2) |
0-100/500/5000ppm |
<±2%(F.S) |
0.01ppm |
≤20second |
nitric oxide(NO) |
0-20/100ppm |
<±2%(F.S) |
0.01ppm |
≤20second |
nitric oxide(NO) |
0-2000ppm |
<±2%(F.S) |
0.1ppm |
≤20second |
nitrogen dioxide(NO2) |
0-20ppm |
<±2%(F.S) |
0.01ppm |
≤20second |
nitrogen dioxide(NO2) |
0-200/1000/5000ppm |
<±2%(F.S) |
0.1ppm |
≤20second |
chlorine gas(CL2) |
0-10ppm |
<±2%(F.S) |
0.001ppm |
≤20second |
chlorine gas(CL2) |
0-20ppm |
<±2%(F.S) |
0.01ppm |
≤20second |
chlorine gas(CL2) |
0-200ppm |
<±2%(F.S) |
0.1ppm |
≤20second |
ammonia(NH3) |
0-50/100ppm |
<±2%(F.S) |
0.01ppm |
≤20second |
ammonia(NH3) |
0-1000/5000ppm |
<±2%(F.S) |
0.1ppm |
≤20second |
ammonia(NH3) |
0-100%LEL |
<±2%(F.S) |
0.1%LEL |
≤20second |
hydrogen(H2) |
0-100%LEL |
<±2%(F.S) |
0.1%LEL |
≤20second |
hydrogen(H2) |
0-1000ppm |
<±2%(F.S) |
0.1ppm |
≤20second |
hydrogen(H2) |
0-20000ppm |
<±2%(F.S) |
1ppm |
≤20second |
hydrogen(H2) |
0-40000ppm |
<±2%(F.S) |
1ppm |
≤20second |
hydrogen(H2) |
0-100%Vol |
<±2%(F.S) |
0.1%Vol |
≤20second |
Note: Other gases not listed in the above table can be consulted by phone.