Portable portable composite gas analyzer

NegotiableUpdate on 11/03
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

OS50T series portable portable composite gas analyzer features: ★ It can simultaneously detect 1-6 gases and can be expanded to 18 gases. Units can be freely switched. Units can be selected: PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/L

Product Details



OS50TSeries portable portable composite gas analyzer features:

Can simultaneously detect 1-6Gas type, expandable to 18Gas species, units can be freely switched

Units available: PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/L.

型号可选: OS50T-II、OS50T-III、OS50-T-IV、OS50T-V、OS50T-VI、OS50T-VII、OS50T-VII、OS50T-VIII、OS50T-IX、OS50T-X 等

Built in pump suction measurement, integrated with water vapor and dust filters, fast response, supports long-distance sampling

Built in water vapor and dust filters prevent sensors and instruments from being damaged by water vapor and dust, and can be used in high humidity and high dust environments;

Sampling distance greater than 10 meters, special gas path design, can be directly detected; Negative or positive pressure of 0.5 to 2 kilograms of gas has no effect on the measurement results.

Rich human-machine interface

3.5-inch high-definition color screen, displaying real-time concentration, alarm, time, temperature, humidity, storage, communication, battery level, charging status, concentration units

Information such as gas molecular formula and gas name; The menu interface uses high-definition simulation graphics to display the function names of each menu.

Large capacity data storage function, supporting multiple storage methods

Standard 100000 data storage capacity, larger capacity can be customized; Optional USB or SD card storage function, supporting real-time storage, scheduled storage, or only storing alarm concentration data; support

Data can be viewed and deleted locally, or uploaded to a computer via USB, infrared communication, or RS232 interface,


Analyze data and store and print it using upper computer software. Support remote wireless transmission (optional function).

Multiple communication interfaces and printing functions

Infrared communication interface (optional), USB interface, RS232 interface automatic recognition, optional built-in or external wireless infrared printer.

Print content: company name, gas name, date and time, environmental temperature and humidity, concentration data, test results (whether qualified).

High temperature gas detectionOptional

Optional high-temperature sampling and cooling filter handle or high-temperature and high humidity pretreatment system can detect flue gas at a temperature of 1300 degrees. Gas detection at higher temperatures can be customized.

Three display modes can be switched

Simultaneously display four gas concentrations, with large font circulating to display the concentration of a single channel gas, and real-time curve display.

Graphical display

Reflect the trend of gas concentration changes over a period of time in the form of a curve.

Infrared remote control

Standard infrared remote control, with one click operation through the infrared remote control function keys, such as modifying alarm points, concentration calibration, zero calibration, and eliminating

Sound, factory reset, enter menu, view records, 4mA output, 20mA output (this function is required for calibrating other acquisition devices).

Data recovery function

You can choose to partially or fully restore, eliminating the worries caused by misoperation.

● Can be set to display the maximum value, minimum value, and average value

standardUSBCharging, with charging protection function, supports USBhot-swapping

Can be charged with a computer or power bank, compatible with mobile phone chargers; Has overcharge, overdischarge, overvoltage, short circuit, and overheating protection; 5-level precise power display;

The detector can work normally during charging.

Adopting through10000mALarge capacity rechargeable polymer battery that can work continuously for a long time

High precision temperature and humidity measurement (optional)

Support real-time detection or scheduled detection

When not detecting, the pump can be turned off to extend the startup time.

Multiple alarm methods, with multi-dimensional and three-dimensional indication of alarm status during alarm

Includes sound and light alarms, vibration alarms, and visual alarms on the display screen. The types of alarms include concentration alarm, undervoltage alarm, and fault alarm.

Multiple alarm mode settings

Low alarm, high alarm, interval alarm, weighted average alarm.

● Misoperation recognition function

Automatic identification and prevention of concentration calibration errors can avoid operational errors caused by human factors.

Zero point automatic tracking, long-term use is not affected by zero drift

Multi level calibration of target points to ensure measurement linearity and accuracy

Chinese and English interface selectable

● Wide operating temperature: -40 ° C~+70℃, supports temperature compensation

log recording

Record calibration logs, maintenance logs, fault records, fault resolution measures, sensor life expiration reminder, and next concentration calibration time reminder function.

Meet the requirements of intrinsic safety circuit design, anti-static, anti electromagnetic interference, pass national standard testing andCMCCertification of Production License for Measuring Instruments

Protection level up toIP66Waterproof, dustproof, explosion-proof, and shockproof

OS50TSeries portable portable composite gas analyzerTechnical Specifications:

gas detection

composite gasOptional: Can simultaneously detect any 16Gas concentration and temperature/humidity can be expanded to 18 different gases

Testing Scope

Refer to the attached table

resolution

Refer to the attached table

Detection Principle

Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, etc., depending on gas, range, on-site environment, and user requirements.

sensor lifespan

Electrochemical principle takes 2-3 years, oxygen can be used for 2 or 6 years, infrared principle takes 5-10 years, chemical combustion takes 3 years, and thermal conductivity takes 5 years.

Detection method

Built in pump suction, flow rate800milliliter/minute

display mode

3.5inch320X240Large screen high-definition color display with high resolution

detection accuracy

≤± 2% F.S (higher precision can be customized)

uncertainty

≤±2%

Linearity

≤±2%

repetitiveness

≤±2%

alarm method

Sound and light alarm, visual alarm, sound and light alarm+Visual alarm, turn off alarm

response time

T9020second

recovery time

30second

working power supply

DC3.6V

battery capacity

3.6VDC10000mARechargeable polymer battery,Equipped with overcharge, overdischarge, overvoltage, and short-circuit protection functions

Usage environment

temperature-40~+70℃; Relative humidity ≤0-99%RH

Sample gas temperature

-40~+70 Optional high temperature sampling and cooling filter handle or high temperature and high humidity pretreatment system for detection1300The concentration of flue gas at ℃

Temperature measurement (optional)

-40℃~+120 ℃ accuracy 0.5 ℃

Humidity measurement

0-100%RHAccuracy 3% RH

data storage

standard capacity10Ten thousand pieces of data, optionalCFCardUDisk storage, unlimited capacity, supports local viewing, deletion, or data export,

Free upper computer communication software, storage function defaults to off state, can be set to on state, storage time interval can be set arbitrarily

communication interface

InfraredUSBTheRS232automatic recognition

printer

Optional, built-in micro printer or external micro wireless infrared printer

Interface language

Chinese or English can be set, default Chinese interface

Explosion-proof type

intrinsically safe

Explosion-proof marking

Explosion proof Exd Ⅱ CT6

Protection level

IP66Rain and water splashes, dust prevention

Overall dimensions

230×210×120mm(L×H×W)

Weight

2.5Kg

Standard Appendix

Instruction manual, certificate of conformityUSBCharger (including data cable), aluminum alloy instrument box40cmStainless steel sampling handle(1Rice hose)

Optional accessories

Built in micro printer, external micro wireless infrared printer, temperature and humidity measurement functionUDisk storage, wireless data communication function

High temperature sampling and cooling filter handle, high temperature and high humidity pretreatment system, external remote sampling pump, multiple humidity and dust filters1.2 mScalable sampling handle(1Rice hose), CD (upper computer communication software)

Application scenarios

All occasions requiring gas concentration detection, such as petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, air treatment, etc


Common Gas Appendix:OS50TSeries portable portable composite gas analyzer


Common Gas Appendix:

gas detection

range

(Other ranges can be customized)

precision

(更高精度可定制)

resolution

(Higher resolution can be customized)

response time

flammable gas(EX)

0-100%LEL

<±2%(F.S)

0.1%LEL

10second

flammable gas(EX)

0-100%Vol

<±2%(F.S)

0.1%Vol

10second

methane(CH4)

0-100%LEL

<±2%(F.S)

0.1%LEL

5second

methane(CH4)

0-100%Vol

<±2%(F.S)

0.1%Vol

10second

oxygen(O2)

0-30%/100%Vol

<±2%(F.S)

0.01%Vol

15second

carbon monoxide(CO)

0-500/1000/2000ppm

<±2%(F.S)

0.1ppm

20second

carbon monoxide(CO)

0-20000/100000ppm

<±2%(F.S)

1ppm

20second

carbon dioxide(CO2)

0-2000/5000ppm

<±2%(F.S)

1ppm

20second

carbon dioxide(CO2)


<±2%(F.S)

1ppm

20second

carbon dioxide(CO2)

0-10000/50000ppm

<±2%(F.S)

1ppm

20second

carbon dioxide(CO2)

0-20/50/100%Vol

<±2%(F.S)

0.01%Vol

20second

formaldehyde(CH2O)

0-10/50ppm

<±2%(F.S)

0.001/0.01ppm

20second

formaldehyde(CH2O)

0-1000ppm

<±2%(F.S)

0.1ppm

20second

ozone(O3)

0-1ppm

<±2%(F.S)

0.001ppm

20second

ozone(O3)

0-10/50/100ppm

<±2%(F.S)

0.01ppm

20second

ozone(O3)

0-2000ppm

<±2%(F.S)

0.1ppm

20second

hydrogen sulfide(H2S)

0-10ppm

<±2%(F.S)

0.001ppm

20second

hydrogen sulfide(H2S)

0-50/100ppm

<±2%(F.S)

0.01ppm

20second

hydrogen sulfide(H2S)

0-200/1000/2000ppm

<±2%(F.S)

0.1ppm

20second

sulfur dioxide(SO2)

0-10ppm

<±2%(F.S)

0.001ppm

20second

sulfur dioxide(SO2)

0-20ppm

<±2%(F.S)

0.01ppm

20second

sulfur dioxide(SO2)

0-100/500/5000ppm

<±2%(F.S)

0.01ppm

20second

nitric oxide(NO)

0-20/100ppm

<±2%(F.S)

0.01ppm

20second

nitric oxide(NO)

0-2000ppm

<±2%(F.S)

0.1ppm

20second

nitrogen dioxide(NO2)

0-20ppm

<±2%(F.S)

0.01ppm

20second

nitrogen dioxide(NO2)

0-200/1000/5000ppm

<±2%(F.S)

0.1ppm

20second

chlorine gas(CL2)

0-10ppm

<±2%(F.S)

0.001ppm

20second

chlorine gas(CL2)

0-20ppm

<±2%(F.S)

0.01ppm

20second

chlorine gas(CL2)

0-200ppm

<±2%(F.S)

0.1ppm

20second

ammonia(NH3)

0-50/100ppm

<±2%(F.S)

0.01ppm

20second

ammonia(NH3)

0-1000/5000ppm

<±2%(F.S)

0.1ppm

20second

ammonia(NH3)

0-100%LEL

<±2%(F.S)

0.1%LEL

20second

hydrogen(H2)

0-100%LEL

<±2%(F.S)

0.1%LEL

20second

hydrogen(H2)

0-1000ppm

<±2%(F.S)

0.1ppm

20second

hydrogen(H2)

0-20000ppm

<±2%(F.S)

1ppm

20second

hydrogen(H2)

0-40000ppm

<±2%(F.S)

1ppm

20second

hydrogen(H2)

0-100%Vol

<±2%(F.S)

0.1%Vol

20second




Note: Other gases not listed in the above table can be consulted by phone.