    No. 163-3 Dongfang East Road, Dongfang Avenue, Economic Development Zone, Qishuyan District, Changzhou City, Jiangsu Province

Contact Now

Blowing device

NegotiableUpdate on 12/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Overview: The flow meter of the blowing device is composed of a metal tube float flow meter or glass rotor flow meter from Chengfeng Company, combined with a constant flow valve, to form a flow blowing device for flow measurement and ensure constant flow output
Product Details
Overview   Blowing device flowmeterIt is from Chengfeng CompanyMetal tube float flowmeterorGlass rotor flowmeterIn conjunction with a constant flow valve, a flow purging device is formed to achieve flow measurement and ensure constant flow output.
Due to the adherence to the safety, reliability, precise and stable measurement characteristics of Chengfeng company's flow meters, the Chengfeng series blowing device flow meter can ensure a constant flow output when the inlet or outlet pressure changes. It can be widely used in process control such as purging of transmitters and differential pressure level measurement in industries such as petroleum refining, chemical, ethylene, fertilizer, steel, chemical fiber textile, etc.
The design structure of Chengfeng series products fully meets the requirements of industrial control, and the installation conditions fully comply with the requirements of instrument measurement technology.

working principle

According to the schematic diagram of the measurement structure (taking constant inlet pressure as an example), it can be seen that:
The upward force acting on the elastic membrane is:
P2A+P1a . ............(1)
The upward force acting on the elastic membrane is:
P3A+P2a+F . ............(2)
When the pressure is in equilibrium, i.e.: (1)=(2) P2A+P1a=P3A+P2a+F... (3)
As the differential pressure P2-P3 of the pressure regulator diaphragm, we can obtain the following equation:
P2-P3=F/A-a/A(P1-P2). .......(4)
Due to a C (constant value)=P2-P3
When the measuring medium is an incompressible liquid, the RE pressure regulator can adapt to changes in outlet pressure. For equation (4), since P1 is constant and P3 is variable, P3 becomes: P3+Δ P, P2 becomes: P2+Δ P, so:
C (constant value)=P2-P3
feature ·Single channel, dual channel, multi-channel form (optional)
·Single meter installation, panel installation, cabinet installation (optional)
·1/4 "NPT, sleeve, threaded, flange connection (optional)
·6mm, 8mm, 10mm, 15mm, 25mm pipelines
·Switch signal output, 4-20mA signal output (optional)
·Metal structure, simple, sturdy, and aesthetically pleasing
·Can measure process temperatures below 200 ℃
·Can measure process pressure below 6.4MPa
·Flow rate, pressure (optional) on-site indication
·Adopting our LZ series float flowmeter
·Optional precision micro needle valve, convenient, flexible, and easy to adjust on-site flow rate