E-mail
qiyatest@163.com
-
Phone
13537151533
-
Address
Baishigang Third Industrial Zone, Changping Town, Dongguan City
Dongguan Qiya Testing Equipment Co., Ltd
qiyatest@163.com
13537151533
Baishigang Third Industrial Zone, Changping Town, Dongguan City
1、 Performance specifications
1.1 Model: QYLG-10000HK
1.2 Temperature control range: RT+10 ℃~80 ℃ (adjustable)
1.3 Temperature resolution: 0.1 ℃
1.4 Temperature deviation degree: ≤±3℃
1.5Compliant with standards
The design of the maturation room fully considers the customer's usage situation and relevant standards in the field involved, including body standards, electronic and electrical standards, etc. This standard is as follows:
(1) Environmental Testing for Electrical and Electronic Products GB/T2423.2-2001
(2) Code for Design of Low Voltage Distribution GB50054-95
(3) Design Code for Power Supply and Distribution GB5002S2-95
(4) Code for Construction and Acceptance of Grounding Devices in Electrical Equipment Installation Engineering
(5) Classification of Combustion Performance of Building Materials
(6) Code for Acceptance of Construction Quality of Ventilation and Air Conditioning Engineering
IIProtector
7.1 Protective devicesTransmission chain limit protection
Overload relay for electric motor
Leakage protector 、 Circuit breaker Temperature Overrise Preventer
Heater air burning prevention device
motor(Fan/) Overload Relay
Wiring circuit breaker 、 Overtemperature protection, buzzer
3、 Request equipment and facilities
8.1 Power Supply: AC380V 3 Φ 50Hz
Total power of equipment:58KW
The allowable range of voltage fluctuation is within ± 5% of the rated voltage
The possible voltage range for operation is the rated voltage±10%)
8.2 Grounding resistance: below 100 Ω.
4Placement and environmental conditions for use
The placement location and usage environment of this maturation room must meet the following conditions. If unable to meet the requirements, please make sure to contact and discuss with Yu in advance.
① Temperature:+5~+35 ℃
② Humidity: not exceeding 85% RH
③ Atmospheric pressure: 80KPa to 106KPa
④ No direct sunlight or direct radiation from other heat sources.
⑤ No flammable or corrosive gas atmosphere.
⑥ There is no strong airflow convection, strong electromagnetic field influence, or strong vibration around.
⑦ Wet steam and less dust.
⑧ Easy power supply.
⑨ The floor surface is relatively horizontal.
⑩ Place for placing materials during installation work; Same conditions as above and adjacent to the resettlement site.
5、 Provide documents
·Provide 1 copy of the quality certificate upon acceptance and handover
·Provide 1 copy of the user manual during acceptance and handover
·Provide 1 copy of the technical specification document during project negotiation