The working principle of the anti rotation level switch is to use a permanent magnet motor to drive the blades to rotate. When the measured material rises to the blade position, the blade rotation is obstructed, and this resistance is transmitted to the detection device inside the junction box. The detection device then outputs a switch signal to the outside and cuts off the power to stop the blade rotation.
When the material level drops, the blade resistance disappears, and the detection device relies on the tension of the spring to return to its original state. The spring tension is adjusted for different material densities. When the density is high, the spring tension is adjusted to strong or strongest, and vice versa, it is adjusted to weak or weakest.