SDJ-50KV voltage breakdown tester

NegotiableUpdate on 10/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The voltage breakdown tester is mainly suitable for testing the breakdown strength and withstand time of solid insulation materials such as plastics, films, resins, mica, ceramics, glass, insulation oil, insulation paint, cardboard and other media under power frequency voltage or DC voltage;

Product Details

Meet the standards:

1. GB1408.1-2006 "Test Methods for Electrical Strength of Insulation Materials"
2. GB1408.2-2006 "Test Methods for Electrical Strength of Insulation Materials
Part 2: Additional Requirements for Application of DC Voltage Test
3. GB/T1695-2005 "Determination method for power frequency breakdown voltage strength and withstand voltage of vulcanized rubber"
4. GB/T3333 Test Method for Power Frequency Voltage Breakdown of Cable Paper
5. HG/T 3330 Determination of breakdown strength of insulation paint film
6. GB12656 Test method for paper frequency voltage breakdown of capacitors
7. ASTM D149 "Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulation Materials at Industrial Power Supply Frequency"
Mainly applicable to solid insulation materials such as:Testing of breakdown strength and withstand time of media such as plastics, films, resins, mica, ceramics, glass, insulating oil, insulating paint, cardboard, etc. under power frequency voltage or DC voltage;
voltage breakdownThe testing instrument is computer-controlled, and the test curve can be observed online during the testing process; Automatically store test conditions and test results data, and can access, display, and print them

Voltage breakdown testerTechnical Specifications:

1. Input voltage: AC220V/50Hz
2. Output voltage: AC: 0-50kV; DC:0~50kV
3. Output power: 5kVA
4. Measurement range: AC: 0-50kV; DC:0~50kV
5. Measurement error: ≤ 2%
6. Boosting rate: 1kV/s to 5kV/s
7. Voltage endurance time: 0-4H
8. Leakage current: 1-30 mA can be freely set by computer software
9. Power supply: AC 220V ± 10% single-phase AC voltage and 50Hz ± 1% frequency
10. Test environment temperature: 15-30 ℃, relative humidity: 0-85%, can operate stably.
11. Dimensions: length x width x height: 1000mm×750 mm×1350mm
12. Equipment weight:150Kg (reference)
13. Grounding requirements: The instrument needs to be separately grounded, and the grounding should comply with national standards. The metal rod should be buried at least 1.5 meters deep underground

Structural principle:

1. Mainly composed of: boosting system (high-voltage transformer), Siemens PLC control system, electrodes, oil tank, electrode positioning frame, computer data processing system, software, etc;
2. Computer - Siemens PLC Control System - Voltage Regulating Device - Step up Transformer - Sample;
3. High voltage transformers mainly generate the DC voltage required for the sample;
4. A voltage regulator is used to regulate the input voltage of a step-up transformer to generate the required input voltage for high voltage;
5. Voltage measurement is mainly measured from the measuring end of the high-voltage transformer, which is linear with the measuring end of the high-voltage transformer;
6. The discharge system will automatically discharge after the experiment is completed to avoid potential harm to human health caused by discharge;

Computer systems and software packages:
1. The experimental software is a powerful, easy-to-use, and visually intuitive experimental software system developed by our company.
2. By using computer control and human-machine dialogue, the insulation medium's power frequency voltage breakdown and power frequency withstand voltage test are completed.
3. During the experiment, the test curve can be dynamically drawn, and the test curve can be overlaid with multiple colors for comparison, locally enlarged, and any section of the curve can be analyzed by enlarging the area;
4. Can edit and modify experimental data, flexible and applicable;

5The experimental conditions and test results can be automatically stored;
6. The format of the test report is flexible and adaptable to meet the different needs of different users;
7. The validity of curve data in a set of experiments can be manually selected;
8. The experimental result data can be imported into Excel and edited in WORD documents;
9. The software equipment personnel management function allows test personnel to set their own test items and parameters, and after setting their own test content, others cannot enter the program;
10. The overcurrent protection device has sufficient sensitivity to ensure that the power is cut off within 0.1 seconds when the sample breaks down;
11. Durability of instrument operation: The instrument can operate continuously without the need for periodic shutdowns to protect it.

Software operation interface:

Parameter settings:

Performance characteristics:

(1)Threshold protection: If the door is not closed, even if the power on point experiment starts, the device will not respond, and the software will prompt that the safety door is not closed.
(2) Voltage zeroing protection: If there is a sudden power outage during the experiment, it will automatically return to zero position after the next power on, ensuring that the initial voltage is at zero position
(3) Termination voltage protection: The termination voltage can be set through software to ensure that if there is an abnormal voltage rise during the boosting process, it will automatically terminate and return to zero
(4) High voltage mechanical limit: If the software system loses control and the voltage continues to rise, it will automatically return to zero after reaching the high voltage limit. If it does not stop after breakdown, data will be collected through an overcurrent protector to ensure that the voltage automatically returns to zero. There is a high voltage indicator light, and the status of the indicator light can be observed to determine whether the voltage is actually rising or at zero. If the experiment is conducted for a long time, in order to ensure the good operation of the equipment, the equipment has a transformer exhaust port to ensure the good operation of the transformer and increase the service life. If there is any odor or burning and smoking phenomenon in the sample during the experiment, it can be eliminated through the exhaust system.
(5) Independent grounding protection
(6) Short circuit protection
(7) Software misoperation protection
(8) Leakage protection
(9) End of experiment discharge protection
Main configurations:

1. 1 host
2. 1 set of discharge device
3. 1 computer
4. 1 printer
5. 1 set of control software
6. 1 set of experimental electrodes
7. 1 fuel tank
8. 1 test bench

9. 1 copy of instruction manual

10. 1 certificate of conformity

11. 1 copy of packing list