Phone
15817589008
-
Address
Building A, No. 68 Nanhu Village Road, Qiaotou Community, Qiaotou Town, Dongguan City
Dongguan Tianshuo Testing Equipment Co., Ltd
15817589008
Building A, No. 68 Nanhu Village Road, Qiaotou Community, Qiaotou Town, Dongguan City
1、 Main functions of the device:
1. The salt dry wet composite corrosion test chamber is designed to simulate natural conditions that are close to voids in accelerated corrosion testing. It simulates the conditions commonly encountered in natural environments and performs self-healing tests under harsh conditions several times that of the natural environment, such as salt spray, dry, humid, room temperature static, low temperature, etc. The tests can be performed in any order or separately.
2. The main test products are aimed at products used under intense environmental changes, such as automotive and motorcycle parts, aviation equipment, photography equipment, building materials, electroplated coatings, and electronic motor systems, which are all suitable for metal electrochemical corrosion resistance
2、 Equipment specifications:
1、 Experimental space: 1200 * 800 * 600 mm (L*W*H)
2、 Outer box size: 2800 * 1200 * 1450mm (L * W * H)
3、 Effective volume: 480L
3、 Main technical parameters:
1. Temperature and humidity technical parameters:
1.1 Temperature and humidity range:
Temperature: 0-85 ℃
Humidity: 20% to 98% RH
|
1.2Heating and cooling rate: |
|
|
room temperature---------> 80 ℃about45minute |
|
|
1.3machine precision: |
|
|
bias: |
|
|
Wen degree:±2 ℃ |
|
|
wet degree: +2/-3% RH |
|
|
volatility: |
|
|
Wen degree:±0.5℃ |
|
|
wet degree:±3%RH |
|
|
uniformity: |
|
|
Wen degree: ±1.0℃ |
|
|
wet degree:±2.0%RH |
|
2. Salt spray test conditions:
1. Laboratory temperature: 35 ℃± 1 ℃/50 ℃± 1 ℃
2. Pressure bucket temperature: 47 ℃± 1 ℃/63 ℃± 1 ℃
3. Salt water temperature: 35 ℃± 1 ℃/50 ℃± 1 ℃
4. spray volume (m1/80cm ²/h) 1.0~2.0 (collect at least 16 hours, and take the average value)
5. Relative humidity: above 85%
6. Salt water concentration: 5% or 5% concentration plus 0.26 grams of copper chloride (CuCl2 2) H2O)
7. Air pressure: 1.00 ± 0.01 kgf/cm²
8. pH value: 6.5~7.2 3.0~3.3
9. Laboratory capacity: 270 L
10 Salt Water Bucket Capacity: 25 L
11. Normal temperature drying, humid heat, forced drying, salt spray cycle: 1 min~9999h
Installation angle of 12 test samples: 15 °~30 °
4、 ConclusionStructure description:
1. The laboratory adopts imported technology PP Polypropylene board (Taiwan South Asia), thickness 12 mm. Durable temperature at 95 ℃.
2. The laboratory sealing cover is imported PP Polypropylene board (Taiwan South Asia), thickness 12 mm。
3. The reagent replenishment bottle adopts a hidden water level gauge, which is easy to clean and not easy to break.
4. The pressure air tank adopts high pressure resistance PP The insulation effect of the bucket is excellent.
5. The laboratory basket frame adopts a flat dividing frame, which can adjust the angle freely. The four sides of the test piece are completely consistent in terms of falling and receiving fog, and there are many test pieces placed.
6. The sealing cover adopts cylinder automatic lifting and lowering
7. Adopting a 304 stainless steel chassis and four casters
8. Water addition system: adopting automatic and manual water addition and replenishment systems, automatically or manually replenishing when the water level is too low
9. A transparent glass observation window, combined with a defogging device, facilitates clear observation of the experiment during the testing process.
10. Equipped with a device runtime controller that automatically shuts down after running time has accumulated
11. Air supply system: Air pressure is 1 kg/cm² Two stage adjustment
**Adjust to 2 times kg/cm² Imported air screening program with drainage function; **Adjusted to 1 kg/cm² pressure
12. spray method:
12.1. The Bernoulli principle is used to extract salt water and then atomize it uniformly, without any obstruction or crystallization, ensuring the standard of continuous testing.
12.2. Nozzle: Made of special glass nozzle, the spray volume and angle can be adjusted.
12.3. spray mode: continuous.
|
5、 Set upBackup control system: |
|||
|
1.Imported controller,Control temperature and humidity separately(Japan)OYOColor touch screen controlU-8256P). 2Controller 2.1Controller specifications Setting method:Programmable and fixed value settings Memory capacity: 1400The segments can be freely combined into140A program memory,999number of cycles set the scope:Temperature conditions:PT_1:–50~150℃,PT_2:-100~200℃ Humidity conditions:0-100%RH display range:Temperature conditions:–50~150℃,PT_1:–50~150℃,PT_2:-100~200℃ Humidity conditions:0-100%RH Time:9999 hour59 divide Set resolution:temperature+ 0.01℃ Humidity:+ 0.1%RH Time:1minute display resolution:temperature+0.1F. S+1digit humidity: +0.1%RH input signal: PT(100Ω) DC入力:temperature:-1V~2Vhumidity:0V~1V control mode:Participate in the groupPIDcontrol and harmonyFuzzycontrol Fixed slope setting:temperature0~9.9℃ per minute humidity0~9.9%RHper minute 2.2Screen display function: .Adopting human-machine dialogue mode,Adopting touch input and control .Temperature and humidity setting test value display .Temperature and humidity setting(SV)actual(PV)Value displayed directly .Can display the execution program number,segment,Remaining time and number of cycles,Running time display .Program editing and graphical curve display,Real time display of program curve execution function .Having a separate program editing screen,Each page can be inputted4Temperature and humidity of each segment,time .Fixed point or program action status display .The screen can be adjusted for backlight,Backlight time can be set .The screen display protection function can be set to be timed or manually turned off .Program replication,COPY,Connection function,Edit experiment titles and other program editing functions .Language conversion can be switched to Simplified Chinese/Fanzhong/英语 .data acquisition,export,View graphic functionality .PIDAutomatic calculation andFUZZYcontrol 2.3Program capacity and control functions: .Available program quantity:*Big120group,1A program can be created by1~100Composed of segment combinations .Available memory capacity:1200 SEGMENTS .Repeatable command execution:Each command can reach999time .The slope setting of the program can be set by the timeline .Programs can be linked for use .The production of the program adopts a conversational style with simple operation .Having an editor,**,Insertion and other functions .tool2Group time signal output control(Controllable control of the test substanceON/OFFaction) .have9groupPIDParameter Settings .There is a skip in program execution,Maintain functionality .Having power-off program memory,Automatically start and continue executing program functions after power restoration 2.5RS-232Communication interface .Can display curves,data acquisition .Equipped with scheduled startup and shutdown functions .Having a date,Time adjustment function .Button and screen lock(LOCK)function .Can be used as a monitoring and remote control system |
|||
|
3.Recorder is a specification for purchase. |
|||
|
4.Temperature control of pressure air tank0-99.9℃,LCD dual digit non display withP.I.DAutomatic calculation,Control error ±0.3℃ (Omron JapanomRon) |
|||
|
VIfreezesystem: |
|||
|
1.Compressor: European and American imported energy-saving fully enclosed industrial low-temperature single-stage compressor(Taikang, France) 2.Condenser: fin type with heat dissipation motor(Taiwan Yongqiang) 3.Evaporator: finned multi-stage automatic load capacity adjustment(Taiwan Yongqiang) |
|||
|
4.Refrigerant: The entire series uses environmentally friendly refrigerantsR23TheR404TheR507(Lianxing, USA) |
|||
|
5.Expansion system:Freezing System with Capillary Capacity Control. 6.Copper tube: internal spiral typeK-TYPERefrigerant copper tube. 7.Other: Original imported drying screening program, oil separator, solenoid valve and other refrigeration equipment (Danfoss Mexico) 8.Cooling method: The cooling method adopts air cooling, |
|||
|
7、 Heating upHumidification system: |
|||
|
1. Using indirect heating method, the heating speed is fast and the standby time is reduced. When the temperature reachesON.OFFSwitching, precise temperature, low power consumption (heating tube made of highly corrosion-resistant titanium tube). |
|||
|
2.Humidifier bucket: The humidifier bucket adoptsSUS#304Made of stainless steel,And equipped with a water level observation window and a water level solenoid valve |
|||
|
3.Water tank: |
|||
|
a.Concealed front mounted plastic water tank1only |
|||
|
b.Automatic water supply pump1a(Automatically supply water from the lower water tank to the upper water tank) |
|||
|
c.Water recovery device and filtration treatment |
|||
|
8air volumeCirculating system: |
|
|
|
|
1.Adopting multi wing divergent fans and sealed motors,Not easily lose oil and constrict the center; |
|||
|
2.Diffusion heavy straight,Level exchange,Arc shaped circulating air supply method; |
|||
|
3.Adjustable side blowing air outlet and protective net recycling port; |
|||
|
4.Special adjustable white leaf air circulation system. |
|||
9、 SecurityProtective measures:
1. A safe and reliable grounding protection device;
2. Laboratory over temperature protection;
3. Heater short circuit and overload protection;
4. Compressor overpressure protection
5. Compressor current protection;
6. Compressor overheat protection;
7. Overload protection for blower motor.
8. Motor overload protection;
9. Humidification and water shortage protection;
10. Line fuse
10 equipmentUsage barItem:
1. Environmental conditions: Temperature range of 5-35 ℃; Humidity: ≤ 85% R.H;
2. Power supply: AC 1ψ 4.5KW 220V 50HZ(R、N Add up grounding wire) (voltage fluctuation ≤± 10%)
3. Grounding protection: Grounding resistance ≤ 4 Ω
4. Installation site requirements: The distance between the left, right, and rear wall panels of the test box and the wall should not be less than 800 mm, The distance from the front to the wall shall not be less than 1000 mm。 The user must provide an independent distribution switchgear and be responsible for connecting the external power supply of the equipment.
5. Weight: 300kg
6. Gas distribution: The equipment gas source provided by the buyer is at a pressure of 6-6.5 kg/cm2If the seller's equipment has special gas source requirements (such as air pressure, oil content, water content, dust content standards, etc.), the seller is responsible for entering the gas path components used for the final life of the equipment. The water pressure of the equipment water source provided by the buyer is 2-3 kg/cm2
11、 Meet the standards:
1. GB/T20854-2007/ISO14993-2001 Dry and Wet Salt Spray Test
2. GB-T5170.8-2008_ Inspection methods for environmental testing equipment for electrical and electronic products _ Salt spray testing equipment
3. GJB150.11A-2009 Military Equipment Laboratory Environmental Test Methods Salt Spray Test
4. GBT2424.17-2008 Salt Spray Test Method
5. GB-T2423.18-2000 Sodium Chloride Alternating Salt Spray Test Method
6. GB-T2423.3-2006 (IEC6008-2-78-2001) Test Cab: Constant Damp Heat Test Method
7. GBT2423_1-2008 Damp Heat Alternating Test Method