Salt spray testing machine SC-60A series

NegotiableUpdate on 08/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Salt spray testing machine is used to test the corrosion resistance of products made from various materials that have undergone anti-corrosion treatments such as electroplating, anodizing, spraying, and rust proof oil on their surfaces

Product Details

Salt spray testing machine
The salt spray test is conducted on surfaces of various materials that have undergone anti-corrosion treatments such as electroplating, anodizing, spraying, and rust proof oil to test the corrosion resistance of their products.
Product execution standards:
GB/T2423.17-2008/lEC 60068-2-11-11981Salt spray test method
ASTM.B117-2009 Salt Spray Test
◆ JlS H8502 Salt water spray test method
◆ GB/T10125-2012/lSO 9227-2006 Salt water spray test method
GB/- T5170.8-2008 Inspection Methods for Environmental Testing Equipment of Electrical and Electronic Products - Salt Spray Testing Equipment
GB/T5170.11-2008 Inspection methods for corrosive gas testing equipment
◆ GB/T10587-2006 Technical Conditions for Salt Spray Test Chamber
Technical parameters:

model

SC-60A

SC-90A

SC-120A/120A2

SC-160A

SC-200A

Chamber size in the laboratoryW×D×Hmm

600×600×500

900×600×500

1200×800×500

1600×1000×500

2000×1200×600

Test outdoor box sizeW×D×Hmm

1150×672×1090

1450×842×1200

2080×1240×1285

2480×1450×1520

2900×1650×1550

Laboratory temperature

Salt water test method(NSS AASS35Corrosion resistance test method (CASS) 50 ℃± 1 ℃

Pressure bucket temperature

Salt water test method(NSS AASS47Corrosion resistance test method (CASS) 63 ℃± 1 ℃

Laboratory capacity

108L

270L

480L

800L

1440L

Salt water tank capacity

15L

25L

40L

40L

40L

brine concentration

Concentration of sodium oxide solution5%Or concentration of sodium oxide solution5%Add per liter0.26Copper chloride(CuCl₂2H₂O

Compressed air pressure

1.00±0.1kgf/cm2

Spray amount

1.00±2.0ml/80cm2/h(At least collect)16Hour, take its average)

Relative humidity in the laboratory

85%the above

PH value

6.57.2 3.03.2

spray mode

Continuous spray

power supply

AC220V1Φ10A

AC220V1Φ15A

AC220V1Φ20A

AC220V1Φ20A

AC220V1Φ30A