Side flow end expiratory carbon dioxide sensor

NegotiableUpdate on 01/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Sifang Optoelectronic Side Flow End Breath Carbon Dioxide Sensor is a CO2 sensor module designed based on the principle of infrared absorption spectroscopy, used to measure the concentration of CO2; Can be applied to devices such as monitors, nutritional metabolism analyzers, and exercise centers. It has the advantages of high precision, good temperature characteristics, low power consumption, fast response time, compact appearance, and flexible integrated installation.
Product Details

Sifang OptoelectronicsSide flow end expiratory carbon dioxide sensorIt is a CO2 sensor module designed based on the principle of infrared absorption spectroscopy, used to measure the concentration of CO2; Can be applied to devices such as monitors, nutritional metabolism analyzers, and exercise centers. It has the advantages of high precision, good temperature characteristics, low power consumption, fast response time, compact appearance, and flexible integrated installation.

Side flow end expiratory carbon dioxide sensorProduct Features

Autonomous NDIR sensor technology

EMI system anti electromagnetic interference

High signal-to-noise ratio and high detection accuracy

Volume based urine integrated installation

0.47W low power consumption

Side flow end expiratory carbon dioxide sensorTechnical Specifications

Detection Principle

Non dispersive infrared technology (NDIR)

data output

CO2 concentration (mmHg), end expiratory CO2, inhaled CO2, respiratory rate

Testing Scope

0 ~ 150 mmHg

resolution

Resolution 0.1mmHg

detection accuracy

0 ~ 40 mmHg: ± 2 mmHg
41~70mmHg: True value ± 5%
71~100mm Hg: True value ± 8%
100~150mmHg; True value ± 10%

Respiratory rate range

0~150BPM

Respiratory rate accuracy

±1 breath

stability

Short term drift: not exceeding 0.8mmHg (4H)
Long term drift: Maintain accuracy specifications within 120H

input voltage

5.00V (±5%)

average current

<100mA

peak current

<200mA

Initialization time

Display within 15 seconds, full specification accuracy within 2 minutes (25 ℃)

compensation

Air pressure: 400 mmHg -850mmHg

Working temperature and humidity

Operation: 0C-55 ℃, 10-909% RH (non condensing)
Storage: -40 ° C~70 ° C,<90% RH (non condensing)

data communication

TTL

lifespan

≥ 10 years

size

57.5mm*23.7mm*24mm

*Please refer to the specification sheet for specific parameters. If you need more technical information, please contact us!