Soft packaging composite film curing room:
1、 Performance specifications
1.1model:QYLG-3000A
1.2Temperature control range:RT+10℃~80℃ (adjustable)
1.3Temperature resolution:0.1℃
1.4Temperature deviation: ≤±2℃
IISoft packaging composite film curing roomessence
2.1Individual internal dimensions:1360/1800/2700mm(W/H/D)
2.2Dimensions: Refer to the design drawings
2.3Warehouse material
(1)Warehouse material Outer color steel, inner box stainless steel
(2)insulation thicknessT/75mm
(3)Insulation material Rock wool(80Bulk density
(5)Main body Whole machine integrated. The storage board adopts rock wool insulation board, and the joint buckle design effectively ensures the sealing and aesthetics inside the aging cabinet. The flame retardant performance of insulation materials complies with the "Classification of Combustion Performance of Building Materials"B2Level regulations.
2.4door door openingW1360*H1800Double door (with tempered glass window)
2.5lighting High temperature and explosion-proof lamp40W
2.6base Using the original ground
3、 Heater and air handling cabinet
3.1circulating fan Wind blade+Extended shaft fan motorAC380V 3Φ1.5KW
3.2Circulating air duct Using bottom return air on both sides and top outlet air transportation, the air transportation plate is made of stainless steel plate, and the air outlet holes are designed according to different air pressures to ensure temperature uniformity3cover/tower
3.3Stainless steel finned heater2.0KW
3.4temperature sensorKType thermocouple sensor(6Road)
Note: The air duct adopts a silent design, and the inlet and outlet air ducts adopt a built-in design, resulting in low noise during equipment operation
4、 Control cabinet
4.1Operating surface cold-rolled steel plate t1.0mm powder coating (standard color), installed on the door
4.2electric box Cold rolled steel platet1.0mmPowder coating (standard color), installation equipment top
5、 Control interface
5.1controller
Adopting intelligent microcomputerPID+SSR/SCR.Stable and precise control accuracy. Industrial control architecture,Has very high reliability and stability,Continuous running time. Setting accuracy: Temperature:0. 1℃
VIProtector
6.1Protector Leakage protector, circuit breaker, temperature rise protector
Heater air burning prevention device
motor(Fan)Overload relay
Wiring circuit breaker, over temperature protection, buzzer