The walk-in constant temperature and humidity laboratory is an essential testing equipment for aviation, automotive, home appliances, scientific research, and other fields. It is used to test and determine the parameters and performance of electrical, electronic, and other products and materials after undergoing high temperature, low temperature, alternating humidity, or constant temperature tests. | ||||||||
Equipment parameters | ||||||||
volume(L) |
YH-ZD-9m³ |
YH-ZD-12.9m³ |
YH-ZD -16.8m³ |
YH-ZD-27 m³ |
YH-ZD-35 m |
YH-ZD- 43.3m³ |
||
inner boxW*H*D |
210*210*205 |
300*210*205 |
390*210*205 |
300*210*430 |
390*210*430 |
480*210*430 |
||
outer boxW*H*D |
The actual production size shall prevail. |
|||||||
temperature range |
0~+85℃-20~+85℃-40~+85℃-60~+85℃ room temperature~85℃ humidity35%-98%(10%~98%R.H; 5%~98%R.HSelect conditions for special customization. ) |
|||||||
|
Wen/Humidity fluctuation Wen/Moisture uniformity Wen/Humidity deviation |
±0.5℃/±2% ±0.1℃/±3% ≤±2℃/±3%RH |
|||||||
|
warm-up time Cooling time |
About:3-4℃/divide About:1℃/divide(Special temperature rise and fall linear nonlinear requirements can be customized) |
|||||||
structural material |
Inner box:SUS 304#8Kmirror finish outer box:High grade steel plate baked paint orSUS 304#stainless steel Insulation layer:PUfoaming+ultrafine glass wool |
|||||||
refrigeration system |
French (Taikang) fully enclosed compressor unit, with heat dissipating fin evaporator also serving as a dehumidifier (Choose a water-cooled unit based on the specific situation of the high and low temperature test chamber) |
|||||||
|
heat Humidification system |
Stainless steel finned heating tube air method, Humidification: Stainless steel sheathed electric steam generation method |
|||||||
safety protection |
Compressor overcurrent, overpressure, oil pressure, no fuse overload protection, heating, humidification dry burning, box overheating, water tank water shortage alarm system. |
|||||||
Standard Configuration |
Observation window, testing hole50CM/Barrier rack2Layer, over temperature protector, window observation light, time signal interface |
|||||||
Power(KW) |
The walk-in constant temperature and humidity laboratory is determined based on the size of the model, temperature, and load conditions. |
|||||||
power supply |
AC1¢3W220VorAC3¢5W380V50HZ |
|||||||
The detailed specifications shall be subject to the corresponding technical proposal (spare parts inventory for more than ten years) | ||||||||
|
execution standard 1TheGB/T10586-89Technical conditions for wet heat test chamber 2TheGB/T2423.1-2008Low temperature test chamber test method 3TheGB/T2423.2-2008High temperature test chamber test method 4TheGB/T2423.4-2008Alternating damp heat test method 5TheGB/T2423.22-2002Temperature change test method 6TheGJB150.9Damp Heat Test...... | ||||||||