The TJ270-30A dual beam proportional recording infrared spectrophotometer is the first high-performance infrared spectrophotometer product in China that uses the principle of direct proportional recording by a computer, filling the gap in the domestic market and occupying a leading position in the domestic infrared spectrophotometer market.
This instrument is equipped with a general-purpose high-performance computer and Chinese control data processing software. It uses imported TGS as the receiver, with favorable price, reliable performance, easy operation, and complete functions. It can be widely used in various fields such as petroleum, chemical, pharmaceutical, environmental protection, teaching, materials science, public security, national defense, etc. It is an indispensable analytical and testing instrument for scientific research, production, and teaching.
Performance characteristics
For the first time in China, the principle of direct proportional recording using computers has been adopted
2. Use a high-energy dual dazzling grating to cover the entire working band
3. Use general-purpose high-performance computers for instrument control and data processing
4. Equipped with the latest developed Chinese operating software
5.The use of imported TGS infrared receiving devices ensures the high performance and reliability of the instrument
6. Holding a national approved production license
TECHNICAL INDEX
| Wavenumber range | wavenumber accuracy | resolution | Transmittance accuracy |
| 4000-400cm-1 | ≤±4cm-1(4000-2000cm-1) ≤±2cm-1(2000-400cm-1) |
1.5cm-1 (near 1000cm-1) | ≤± 0.2% T (excluding noise level) |
| IoLine straightness | stray | Test mode | scanning speed |
| ≤±2%T | ≤0.5%T(4000-650cm-1) ≤1%T(650-400cm-1) |
three types (Transmittance, absorbance, single beam) |
fifth gear (Fast, fast, normal, slow, very slow) |
| Slit program | in response to | way of working | Horizontal and vertical coordinate expansion |
| fifth gear (Very wide, wide, normal, narrow, very narrow) |
Four levels (Fast, fast, normal, slow) |
three types (Continuous scanning, repeated scanning, fixed wavelength scanning) |
arbitrary |