-
E-mail
sdxwsale@163.com
- Phone
-
Address
Room 803, Building 5, No. 38 Courtyard, Haidian Greenland Center Plaza, Linfeng 2nd Road, Haidian District, Beijing
Beijing Times New Wei Measurement and Control Equipment Co., Ltd
sdxwsale@163.com
Room 803, Building 5, No. 38 Courtyard, Haidian Greenland Center Plaza, Linfeng 2nd Road, Haidian District, Beijing
It is suitable for laboratory or on-site online rapid analysis of water, tap water, discharged wastewater, high concentration sewage and various solutions in Rivers and Lakes
COD content.
?The instrument selection valve component will select the timing of reagent samplingFlexible and diverse channels, versatile functions, with small dead ends
Advantages such as size, easy maintenance, and high lifespan.
?The instrument achieves precise measurement of reagents through a visual photoelectric system, overcoming quantitative errors caused by wear of peristaltic pump tubes; Simultaneously achieving the precision of trace reagentsDetermine the dosage, each dose is only1Milliliters, greatly reducedReagent usage.
?Peristaltic pump negative pressure suction, between reagent and pump tubeThere is always an air buffer zone to prevent corrosion of the pump tube; At the same time, it makes the mixing of reagents more concise and flexible.
?High temperature and high pressure digestion system accelerates the reaction processOvercoming the corrosion of equipment caused by the volatilization of corrosive gases in open systems.
?Adopting imported modified polytetrafluoroethylene transparent hosePipe diameter greater than 1.5mmReduced particle blockage in water samplesRate.
?COD standard solution (500mg/L)/1 bottle
?Distilled water (COD zero point)/ 1 bottle
?COD reagent A/ 1 bottle
?COD reagent B/ 1 bottle
?COD reagent C/ 1 bottle
?Installation of monitoring substation building
1. When there is a significant malfunction in the instrument, users should not attempt to operate it themselvesPlease contact the manufacturer promptly for repairs.
2. If there are differences between the user manual and actual operation, use the instrumentTo be accurate.
3. Some of the chemicals required for this device are corrosive substancesWhen dealing with these drugs, certain preventive measures should be taken.
Method basis: National StandardGB11914-89 "Water Quality - Determination of Chemical Oxygen Demand - Potassium Dichromate"
Measurement range: 5-1500 mg/L Accuracy: not exceeding ± 10
Stability: not exceeding ± 10 within 24 hours
Measurement cycle: The small measurement cycle is 40 minutes
Sampling period: time interval (adjustable from 40 to 9999 minutes) and whole point measurement mode
Calibration cycle: 1-99 days, adjustable at any interval and time
Maintenance cycle: usually once a month, about 30 minutes each time. Reagent consumption: less than 5 yuan/sample
lose Out: RS-232, 4-20mA, RS485 (optional) Environmental requirements: Indoor temperature adjustable, recommended temperature+5~
28℃; Humidity ≤ 90
(Non condensing) Electricity Source: AC230±10
V,50±10
Hz,5A
ruler Inch: Height 1570 x Width 500 x Depth 450mm
its He: Abnormal alarms and power outages will not result in data loss;Touch screen display and command input;
After abnormal reset and power outage, the instrument automatically discharges residual reactants from the instrument,Automatically restore working status
TP1111 online COD monitor, potassium dichromate method, new dimension in the era