Overview
Product parameters External dimensions (mm): 2100WX2400DX2500H Internal dimensions (mm): 2100WX2400DX2500H0 Overall power (kw): 80~120W Overall air volume (m3/min): 1300 Efficient dimensions (mm): 1170 * 570 * 69 Speed control function: 0.45m/s ± 20% Lighting bulb: 30W UV sterilization: 99.99% Order hot wire:
Product Details

Tempered glass cleanroom manufacturer's preparation
1. Framework: Industrial aluminum (or stainless steel square tube, iron square tube spray) is used as the frame to ensure stability, aesthetics, rust resistance, and dust-free.
2. Anti static curtains: Anti static curtains (or tempered glass) are used around the perimeter, which have good anti-static effect, high transparency, clear grid, good flexibility, no deformation, and are not easily aged.
3. Fan filter unit FFU: It adopts a centrifugal fan, which has the characteristics of long service life, low noise, maintenance free, low vibration, and stepless speed change. The fan quality is reliable, the working life is long, and the unique air duct design greatly improves the efficiency of the fan and reduces noise! The internal purification level can reach 100-100K level; Especially suitable for areas with high local purification requirements in the workshop, such as assembly line operation areas.
4. The interior adopts a dedicated purification lamp for the purification room, which does not produce dust.

Characteristics of tempered glass clean room products
The fan sucks in air from the top of the FFU, passes through the primary filter and high-efficiency filter, and the filtered clean air is uniformly sent out to the clean room at a speed of 0.45m/s ± 20% on the entire air outlet surface. Forming a uniform flow layer ensures a vertical unidirectional flow of clean air, thereby guaranteeing the required cleanliness within the workspace.
A clean room is a simple clean room that can be quickly assembled. It has the characteristics of fast installation, short construction period, low price, and easy mobility. Controlling the main production processes in a smaller environment is also the best choice for clean room design.

Maintenance matters for tempered glass clean room
1、 Regularly wipe with alcohol to maintain cleanliness.
2、 The code of conduct for employees, segmented control of the clean room power supply, and ensuring that the entire clean room is not completely destroyed in case of circuit problems. The high-efficiency filter in the air supply system must not be touched by employees with a pen or other objects to prevent fragile filter paper from breaking and affecting the cleanliness of the entire simple clean room. Also, anti-static curtains and hanging curtains need to be taken care of, even if they are made of iron, they will deform and be damaged as long as they are knocked on every day.
3、 The staff entering the clean room should wear protective clothing, dust-free clothes, hats, and shoes to avoid indoor pollution.
4、 The clean room work switch must be turned on ten minutes in advance by personnel before they can enter the work area.

Advantages of Tempered Glass Cleanroom
1. It can be used alone or in combination.
Compared with civil or prefabricated cleanrooms, Class 100 cleanrooms have lower investment, faster results, easier installation, and lower operating costs.
3. Modular structure, easy to improve cleanliness level, strong scalability, and high reuse value.
4. Easy to move (universal wheels can be installed).

Measures to ensure cleanliness inside the cleanroom
To ensure the required cleanliness inside the cleanroom, for the normal operation of the purification air conditioning system and cleanroom, it is necessary to ensure that the air entering the cleanroom is clean. People and objects entering the cleanroom should undergo necessary purification treatment to minimize the amount of dust brought into the cleanroom by people and objects.
(1) Generally speaking, materials entering the clean room should undergo cleaning and necessary purification treatment before being transported to reduce the amount of dust generated by the materials in the clean room. Small items entering the clean room are usually entered through transfer windows between the clean room and the outer corridor or between adjacent rooms with different cleanliness levels. Transfer windows generally come in box type, rotary type, etc.
(2) During the operation of the air purification air conditioning system, all levels of air filters used must be intact without damage or leakage. During the operation of the purification air conditioning system, in order to prevent the air supply system from bringing dust particles that should not enter the room into the room, regular leakage checks must be conducted on the primary, medium, and final air filters used in the system.
(3) People are clean. The measures for personal hygiene mainly include washing, changing shoes and clothes, and air blowing. The pollutants emitted by the human body mainly include self generated pollutants and carried pollutants. There are three types of dust particles carried by the human body; One type is external environmental pollutants randomly attached to hair, clothing, and shoes; And residual pollutants on clothes and shoes. The other is personal smears, such as hair oil, perfume, eye cream, powder, etc. The third type is the wear and tear of clothing. The human body is also one of the main sources of bacteria in clean rooms.