Typical fluorescent filter set

NegotiableUpdate on 02/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

A typical fluorescent filter set is mainly used in fluorescence microscopes, divided into 6 bands and 12 groups of fluorescent filters

Product Details

A typical fluorescent filter set is mainly used in fluorescence microscopes, divided into 12 groups of fluorescent filters in 6 bands.
The fluorescent filter produced by Huibo Optics is manufactured using IAD technology, which has good spectral performance and a long service life. Applying these filters can obtain high-quality images with high contrast, clarity, and realism. Product features: high transmittance (T>90%), deep cutoff background (>OD6), high signal-to-noise ratio, high precision (wavefront distortion<0.25 λ). We have adopted newer filter products such as high contrast rectangular bandpass filters and sharp cut-off broadband filters, with a background cut-off depth increased to 10-6, resulting in a darker background, better contrast, and brighter and clearer images.
No corresponding parameter group found, please add it in the backend property template

12 sets of fluorescent filters in 6 bands

Spectral region

Filter group

characteristic

Stimulating film

Launch pad

Dichroic Mirror

UV

U-1

EF330-380

BF420

DM400

Applied to the UV spectral region

U-2

EF330-380
(WBP365)

BF435

DM400

BF435 has a deep cutoff background

Purple;

V

EF380-420
(BP405)

BF460

DM430

Standard purple spectral region, mercury lamp 405nm, bright fluorescence image

violet

BV

EF400-440 (SP435)

BF480

DM455

Standard blue spectral region, with strong excitation light at 405nm and 435nm

blue

B

EF400-490
(SP490)

BF520

DM505

Standard blue spectral region

B-1

F420-490
(WBP455)

BF520

DM505

Standard blue spectral region

B-2

EF450-490
BP470)

BF520

Suitable for fluorescence immunoassay microscopy

green

G

EF400-550
(SP546)

BF590

DM575

Including wavelengths of 405nm, 435nm, 546nm

G-1

EF460-550
(WBP505)

BF590

DM575

U-band spectral curve



V-band spectral curve



B-1 band spectral curve



G-2 band spectral curve


Mainly used in fluorescence microscopes and other related instruments and equipment that require imaging.