UHZ-158S-UK series plug-in magnetic liquid level controller

NegotiableUpdate on 10/27
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

UHZ-158S-UK series plug-in magnetic liquid level controller main technical parameters precision:+10mm control height: 300~6000mm connection flange size: DN100. DN80, PN1.0 (flange connection) explosion-proof mark explosion-proof type: Exd Ⅱ BT4~6 (limited to 24VDC) intrinsic safety type: Exia Ⅱ CT4~6 control contact capacity: AC220V. 1A (resistive) DC24V, 0.5A control contact life: 5x10 fourth power control contact number: 1.2 three Choose between 4 points (if more than 4 points, please specify when placing an order). Outgoing interface thread: M20x1.5 internal thread. . .....

Product Details

Overview
UHZ-158S-UK series plug-in magnetic liquid level controllerSignal from the liquid level switch. The product is compatible with the corresponding circuit canUsed for petroleum, chemical, textile, printing and dyeing, environmental protection, and civil constructionControl and alarm the liquid level of various open or closed containers.
feature
Simple structure, easy installation, reliable operation, and easy maintenance.Widely applicable and suitable for liquid level control of various media.
structural principle
Using a magnetic float to rise or fall with the liquid level, allowing the sensor to detectThe reed switch at the set position inside the pipe is activated, triggering the contact openingConvert the signal.
Main technical parameters
Precision:+10mm
Control height: 300~6000mm
Connection flange size: DN100. DN80, PN1.0 (flange connection)
Explosion-proof marking
Explosion proof type: Exd Ⅱ BT4~6 (limited to 24VDC)
Intrinsic safety type: Exia Ⅱ CT4~6
Control contact capacity: AC220V. 1A (resistive) DC24V, 0.5A
Control contact life: 5x10 to the fourth power
Control the number of connections: 1.2 three Choose between 4 points (if more than 4 points, please specify when placing an order).
Outgoing interface thread: M20x1.5 internal thread.
TIANKANG
TIANKANG
TIANKANG
Example of Selection
Measure the liquid level of the high-level water tank. The magnetic liquid level controller is a single float with 2 control points. The connecting flange is made of carbon steel with a range of 2000mm. The first control point is normally open (upper limit) at a height of 500mm, and the second control point is normally closed (lower limit) at a height of 1600. It is a normal temperature, normal pressure, and ordinary waterproof junction box.
Selection mark: UHZ-158S-UK-102-1 10-2000-500K/1600B-D-1.0
TIANKANG
Installation, use, and maintenance
Installation position of liquid level controller It is necessary to choose the location with small fluctuations on the liquid, avoid or stay away from the inlet and outlet of the liquid medium, and reduce the impact of the medium fluid on the sensor part of the controller.
The gear ring must be installed firmly to prevent measurement failure or magnetic float detachment.
The connecting flange of the liquid level controller must be paired with the user's container flange.
Application Notice
The magnetic level controller should not be used in situations where the liquid medium contains suspended, impurities, and magnetic substances, which can cause blockage to the float.
For the magnetic liquid level controller with flange connection, our company adopts the HG20592-20635-97 pipe flange standard of the Ministry of Chemical Industry. If other standards or special requirements are used, they can be specified when ordering.
Our company can provide matching liquid level control boxes and control cabinets according to user needs.
In order to enhance the control of switch contact signals and electrical control systems
We recommend the use of UD-1 conversion amplifier and JTX small universal high-power relay for reliability, safety, and practicality. This can reduce the switch current through the on-site controller to a very small level, while the relay can be connected to high-power loads. (Our company can provide relevant products)
Ordering Notice (Please provide the following data when placing an order)
Specifications and models (refer to Table 1 and Table 2)
Range and control height
work pressure
Operating Temperature
Material requirements
Special requirements