E-mail
yafei.wei@pgeneral.com.cn
-
Phone
13681197768
-
Address
No. 3 Pingsan Road, Pinggu District, Beijing
Beijing Puxi General Instrument Co., Ltd
yafei.wei@pgeneral.com.cn
13681197768
No. 3 Pingsan Road, Pinggu District, Beijing
As a professional manufacturer of analytical instruments, Beijing Puxi General Company has been committed to the research and development of atomic absorption spectrometers for many years. In 1997, it launched the highly automated TAS-986 atomic absorption spectrophotometer in China, which uses fully Chinese Windows operating software. All controls of the instrument are completed by computers, greatly reducing the difficulty of operation for analysts, avoiding human errors, and ensuring high analytical accuracy. Received a gold award at the BCEIA Awards in 1997.
Universal TAS-986 Single Beam Atomic Absorption SpectrometerKey Features:
1. The structural design of an integrated flame atomizer and graphite furnace atomizer has achieved automatic switching between flames and graphite furnace atomizers
2. Domestic companies adopt advanced horizontal heating graphite furnace technology to ensure uniform temperature of graphite tubes, reducing chemical interference and memory effects
3. Adopting a rotating lamp frame with eight lamps, automatically selecting the position of each element's hollow cathode lamp
4. Automatically set * * height position and gas flow rate to ensure * * analysis conditions; Automatic wavelength scanning, peak searching, and spectral bandwidth replacement
5. The flame monitor can monitor flame changes at any time. In case of accidental flameout, the instrument will automatically shut down the acetylene flow and prompt an alarm
Technical Specifications:
1. Wavelength range: 190nm-900nm
2. Wavelength accuracy: ± 0.25nm
3. Wavelength repeatability: 0.15nm
4. Heating temperature range: 20 ℃~2650 ℃ (horizontal heating, which is equivalent to 3000 ℃ for vertical heating)
5. Spectral bandwidth: automatic switching between five levels: 0.1, 0.2, 0.4, 1.0, 2.0
6. Resolution: better than 0.3nm
7. Baseline drift: 0.005A/30min
| spectroscopic system | ||
| wavelength range | 190nm-900nm | |
| monochromator | C-T type monochromator device for eliminating aberration | |
| spectral bandwidth | 0.1, 0.2, 0.4, 1.0, 2.0nm: five automatic switching modes | |
| wavelength accuracy | ±0.25nm | |
| Wavelength repeatability accuracy | 0.15nm | |
| resolution | Better than 0.3nm | |
| baseline drift | 0.005A/30min | |
| Performance specifications of universal TAS-986 atomic absorption spectrophotometer for general analysis | ||
| Characteristic concentration (Cu) | 0.03µg/ml/1% | |
| Detection limit (Cu) | 0.006µg/ml | |
| burner | Metal titanium burner | |
| precision | RSD≤1% | |
| sprayer | Efficient glass atomizer | |
| 雾化室 | Corrosion resistant material atomization chamber | |
| Position adjustment | Automatic setting of flame burner height and front and rear positions | |
| safety measures | Equipped with multiple automatic protection functions | |
| Graphite furnace analysis | ||
| Characteristic quantity (Cd) | 0.5×10-12g | |
| Detection limit (Cd) | 1×10-12g | |
| precision | RSD≤3% | |
| Heating temperature range | Room temperature~2650 ℃ | |
| Heating and temperature control method | The power control method for the drying and ashing stage and the high power control method for the atomization stage are controlled by light | |
| Heating condition setting | 9 programs for ramp heating, step heating, and high-power heating | |
| Background correction | ||
| Deuterium lamp background correction | Correctable 1A background | |
| Self suction background correction | Correctable 1A background | |
| data processing | ||
| measurement method | Flame method, graphite furnace method, hydride generation atomic absorption method | |
| Concentration calculation method | Standard curve method (1-3 degree curve), standard addition method; Interpolation method | |
| Repeated measurement times | Calculate the average of 1-20 times and provide the standard deviation and relative standard deviation | |
| Result printing | Parameter printing, data result printing, graphic printing | |
Universal TAS-986 Single Beam Atomic Absorption SpectrometerCore parameters
| Optical system: | Single beam | Detector: | PMT |
| Monochrome components: | echelle | Background deduction: | comprehensive |
| Repeatability: | ≤0.15nm | Detection limit: | 0.006 μ g/mL (flame mode); 1.0×10-12g |