Welcome Customer !

Membership

Help

Shenzhen Anpar Technology Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Volkswagen online fixed iodine toluene detector with display series network version

NegotiableUpdate on 01/30
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Volkswagen online fixed iodine toluene detector with display series network version is the most widely used fixed iodine toluene detector in the Volkswagen series. It can simultaneously have on-site detection concentration display, signal transmission, LED lights, and relay alarm functions. The working principle of the Volkswagen online fixed iodine toluene detector with display series network version is to convert the detected concentration of iodine toluene gas on site into corresponding standard signals (such as voltage signals (such as 0-5/10V), current signals (such as 4-20mA), standard digital signals (such as bus RS-485, RS232), frequency signals, Hart protocol signals, and then transmit the signals to upper computers such as PLC, DCS, alarm control host for unified display, management, and control. The Volkswagen online fixed iodine toluene detector with display series network version comes with one relay (switch signal) inside, which can control the fan and sound and light alarm ..
Product Details

Public online fixed iodine methylBenzene detectorIntroduction to the Network Edition with Display Series

Public online fixed iodineToluene detectorThe online version with display series is the most widely used fixed iodine toluene detector in the Volkswagen series. It can simultaneously have on-site detection concentration display, signal transmission, LED lights, and relay alarm functions. The working principle of the Volkswagen online fixed iodine toluene detector with display series network version is to convert the detected concentration of iodine toluene gas on site into corresponding standard signals (such as voltage signals (such as 0-5/10V), current signals (such as 4-20mA), standard digital signals (such as bus RS-485, RS232), frequency signals, Hart protocol signals, and then transmit the signals to upper computers such as PLC, DCS, alarm control host for unified display, management, and control. The Volkswagen online fixed iodine toluene detector with display series network version has one relay (switch signal) inside, which can control equipment such as fans, sound and light alarms, solenoid valves, etc.

Product Features

★ Internet of Things function: Volkswagen online fixed iodotoluene detector with display series network version can be connectedAnparThe server is used to achieve remote monitoring, alarm reminders, and alarm value settings for mobile phones and computers;

★ Ultra high definition color display screen. Long distance visibility, with a visual distance of 10 meters (5.0 visual acuity);

★ Complete range of standard signal output types; The Volkswagen online fixed iodine toluene detector with display series network version has multiple options for wired output signals.

★ Bilingual operating system: can switch between Chinese and English systems, default to Chinese operating system

★ Black box function: operation and alarm recording, over temperature usage recording, over range usage recording;

★ Complete reminder and alarm functions: sensor expiration reminder function, over concentration alarm function, over temperature alarm function, fault alarm function, instrument calibration reminder function, etc;

★ Explosion proof design, intrinsic safety design, RoHS design;

★ Quick response: Compared with similar products in the same industry, the detection speed is fast;

★ Operation guide: Humanized design, with operation instructions for each function setting to prevent customer misoperation, unique in the industry;

★ Zero point automatic calibration: For certain environmental applications, the instrument can achieve zero point automatic calibration function;

★ Multi level calibration function: a mature technology that can achieve high-precision detection and has been validated in the market for many years;

★ Dual operation mode: button operation+remote control operation

Technical Parameter

Project Content Specific parameters
product name Volkswagen online fixed iodine toluene detector with display series network version
product name Iodine toluene gas transmitter, iodine toluene gas probe, iodine toluene gas detector, iodine toluene gas sensor, iodine toluene gas analyzer
Detect gas For iodotoluene and other gases, please consult the manufacturer or refer to the attached table
measuring range Based on the on-site situation, please consult the manufacturer for details
Display units Ppm, mg/m3, ppb, pphm,% VOL,% LEL (partially switchable)
resolution Determined by the detection range
accuracy ≤± 3% FS (normal accuracy);
repeatability ≤±1%
response time ≤ 3 seconds (T1); ≤ 15 seconds (T90)
recovery time ≤ 20 seconds (T90-T10)
Display mode 320 * 240 high-definition color screen 2.0 inches
Visible distance ≥ 10 meters (5.0 visual acuity)
system language Chinese (default) and English are switchable
operating mode Infrared remote control, buttons (cover opening), remote network (such as mobile app or upper computer software)
detection For more information on diffusion, please consult the manufacturer
Installation method Wall mounted (wall mounted), pole mounted (horizontal or vertical). For more information, please consult the manufacturer
Shell material Subject: Alloy (anti-corrosion and anti-oxidation surface treatment) or stainless steel. Probe: anti-corrosion alloy or 316L stainless steel
Explosion proof sign Dual explosion-proof standards Exd Ⅱ CT6 and Ex Td A21
protection grade IP66
operation temperature -40 ℃~70 ℃ (ordinary catalytic combustion principle sensor)
-40 ℃~270 ℃ (special catalytic combustion)
-40 ℃~50 ℃ (electrochemical)
-20 ℃~50 ℃ (PID principle sensor)
-20 ℃~50 ℃ (infrared/fluorescence gas sensor)
-40 ℃~70 ℃ (thermal conductivity principle sensor)
-40 ℃~420 ℃ (Zirconia principle oxygen sensor)
Working humidity 10%~95%RH, No condensation (humidity>90% RH, optional filter for condensation)
Working pressure 0.08~0.6MPa (thermal conductivity principle sensor)
0.02-0.36MPa (Zirconia principle oxygen sensor)
86-106KPa (Other)
Temperature measurement range -40 ℃~+120 ℃ accuracy ± 1 ℃ (with temperature compensation function)
output signal Two line system 4-20mA
Two line Hart system
Three wire 4-20mA+1 relay (switch quantity, optional function)
Voltage 0-5/10V+1 relay (switch value, optional function)
RS-485+1 relay (switch quantity, optional function)
RS-422+1 relay (switch quantity, optional function)
Three wire current 4-20mA+RS-485+1 relay (switch value, optional function)
Voltage 0-5/10V+RS-485+1 relay (switch value, optional function)
Frequency signal (adjustable)+1 relay (switch quantity, optional function)
Three wire Hart+1 relay (switch value, optional function)
CAN bus+1 relay (switch value, optional function)
Note:Relay (switch quantity) specification: output 2A@30VDC perhaps 0.6A@125VAC
power consumption Electrochemical sensor: P ≤± 0.9W
Ordinary catalytic sensor: P ≤± 2.3W
Low power catalytic sensor: P ≤± 1.2W
Thermal conductivity sensor: P ≤± 1.2W
Infrared sensor: P ≤± 1.4W
PID sensor: P ≤± 1.2W
For other inquiries, please consult the manufacturer
Alarm method Panel LED alarm, display screen character flashing and information reminder, relay output
control output External fan, valve, sound and light alarm
Protection function Intermittent detection, sensor automatic protection function (optional)
service life 2 years (sensors), 5 years (instruments)
Power supply 12-35VDC, Typical power supply 24VDC
size Overall dimensions: 205 * 184 * 93mm (length * width * thickness) - Volkswagen series basic model
Wiring port size: Internal thread M20 * 1.5 (G1/2 internal thread, G3/4 internal thread
1/2NPT internal thread, NPT3/4NPT internal thread are optional);
weight ≥1.65kg
Product Certification Fire certification (mandatory CCCF), metrological certification CMC, explosion-proof certification CE、RoHS、 Third party metrology certification
National patent product certification, three system certification: ISO9001, ISO14001, ISO18001
Execution standards GB 15322.1-2003, GB 3836.1-2010,GB 3836.2-2010, GB 3836.4-2010,
GB 12476.1-2013, GB 12476.4-2010,GB 12476.5-2 013,
JJF 1363-2012, JJF 1368-2012,JJF 1421-2013, JJF 1364-2012
Standard accessory Packaging box, instruction manual, certificate of conformity, warranty card, remote control (included), factory inspection report
Installation bracket (optional), calibration cover (optional)