Volkswagen Online Fixed ChlorpheniramineBenzene detectorIntroduction to the Network Edition with Display Series
Public online fixed chlorineToluene detectorThe online version with display series is the most widely used fixed p-chlorotoluene detector in the Volkswagen series. It can simultaneously have on-site detection concentration display, signal transmission, LED lights, and relay alarm functions. The working principle of the Volkswagen online fixed type p-chlorotoluene detector with display series network version is to convert the detected p-chlorotoluene gas concentration on site into corresponding standard signals (such as voltage signal (such as 0-5/10V), current signal (such as 4-20mA), standard digital signal (such as bus RS-485, RS232), frequency signal, Hart protocol signal, and then transmit the signals to the upper computer such as PLC, DCS, alarm control host for unified display, management, and control. The Volkswagen online fixed p-chlorotoluene detector with display series network version has one relay (switch signal) inside, which can control equipment such as fans, sound and light alarms, solenoid valves, etc.
Product Features
★ Internet of Things function: Volkswagen online fixed p-chlorotoluene detector with display series network version can be connectedAnparThe server is used to achieve remote monitoring, alarm reminders, and alarm value settings for mobile phones and computers;
★ Ultra high definition color display screen. Long distance visibility, with a visual distance of 10 meters (5.0 visual acuity);
★ Complete range of standard signal output types; The Volkswagen online fixed p-chlorotoluene detector with display series network version has multiple options for wired output signals.
★ Bilingual operating system: can switch between Chinese and English systems, default to Chinese operating system
★ Black box function: operation and alarm recording, over temperature usage recording, over range usage recording;
★ Complete reminder and alarm functions: sensor expiration reminder function, over concentration alarm function, over temperature alarm function, fault alarm function, instrument calibration reminder function, etc;
★ Explosion proof design, intrinsic safety design, RoHS design;
★ Quick response: Compared with similar products in the same industry, the detection speed is fast;
★ Operation guide: Humanized design, with operation instructions for each function setting to prevent customer misoperation, unique in the industry;
★ Zero point automatic calibration: For certain environmental applications, the instrument can achieve zero point automatic calibration function;
★ Multi level calibration function: a mature technology that can achieve high-precision detection and has been validated in the market for many years;
★ Dual operation mode: button operation+remote control operation
Technical Parameter
| Project Content | Specific parameters |
| product name | Volkswagen online fixed p-chlorotoluene detector with display series network version |
| product name | P-chlorotoluene gas transmitter, p-chlorotoluene gas probe, p-chlorotoluene gas detector, p-chlorotoluene gas sensor, p-chlorotoluene gas analyzer |
| Detect gas | For chlorotoluene and other gases, please consult the manufacturer or refer to the attached table |
| measuring range | Based on the on-site situation, please consult the manufacturer for details |
| Display units | Ppm, mg/m3, ppb, pphm,% VOL,% LEL (partially switchable) |
| resolution | Determined by the detection range |
| accuracy | ≤± 3% FS (normal accuracy); |
| repeatability | ≤±1% |
| response time | ≤ 3 seconds (T1); ≤ 15 seconds (T90) |
| recovery time | ≤ 20 seconds (T90-T10) |
| Display mode | 320 * 240 high-definition color screen 2.0 inches |
| Visible distance | ≥ 10 meters (5.0 visual acuity) |
| system language | Chinese (default) and English are switchable |
| operating mode | Infrared remote control, buttons (cover opening), remote network (such as mobile app or upper computer software) |
| Testing method | For more information on diffusion, please consult the manufacturer |
| Installation method | Wall mounted (wall mounted), pole mounted (horizontal or vertical). For more information, please consult the manufacturer |
| Shell material | Subject: Alloy (anti-corrosion and anti-oxidation surface treatment) or stainless steel. Probe: anti-corrosion alloy or 316L stainless steel |
| Explosion proof sign | Dual explosion-proof standards Exd Ⅱ CT6 and Ex Td A21 |
| protection grade | IP66 |
| operation temperature | -40 ℃~70 ℃ (ordinary catalytic combustion principle sensor) -40 ℃~270 ℃ (special catalytic combustion) -40 ℃~50 ℃ (electrochemical) -20 ℃~50 ℃ (PID principle sensor) -20 ℃~50 ℃ (infrared/fluorescence gas sensor) -40 ℃~70 ℃ (thermal conductivity principle sensor) -40 ℃~420 ℃ (Zirconia principle oxygen sensor) |
| Working humidity | 10%~95%RH, No condensation (humidity>90% RH, optional filter for condensation) |
| working pressure | 0.08~0.6MPa (thermal conductivity principle sensor) 0.02-0.36MPa (Zirconia principle oxygen sensor) 86-106KPa (Other) |
| Temperature measurement range | -40 ℃~+120 ℃ accuracy ± 1 ℃ (with temperature compensation function) |
| output signal | Two line system 4-20mA Two line Hart system Three wire 4-20mA+1 relay (switch quantity, optional function) Voltage 0-5/10V+1 relay (switch value, optional function) RS-485+1 relay (switch quantity, optional function) RS-422+1 relay (switch quantity, optional function) Three wire current 4-20mA+RS-485+1 relay (switch value, optional function) Voltage 0-5/10V+RS-485+1 relay (switch value, optional function) Frequency signal (adjustable)+1 relay (switch quantity, optional function) Three wire Hart+1 relay (switch value, optional function) CAN bus+1 relay (switch value, optional function) Note:Relay (switch quantity) specification: output 2A@30VDC perhaps 0.6A@125VAC |
| power consumption | Electrochemical sensor: P ≤± 0.9W Ordinary catalytic sensor: P ≤± 2.3W Low power catalytic sensor: P ≤± 1.2W Thermal conductivity sensor: P ≤± 1.2W Infrared sensor: P ≤± 1.4W PID sensor: P ≤± 1.2W For other inquiries, please consult the manufacturer |
| Alarm method | Panel LED alarm, display screen character flashing and information reminder, relay output |
| control output | External fan, valve, sound and light alarm |
| Protection function | Intermittent detection, sensor automatic protection function (optional) |
| service life | 2 years (sensors), 5 years (instruments) |
| Power supply | 12-35VDC, Typical power supply 24VDC |
| size | Overall dimensions: 205 * 184 * 93mm (length * width * thickness) - Volkswagen series basic model Wiring port size: Internal thread M20 * 1.5 (G1/2 internal thread, G3/4 internal thread 1/2NPT internal thread, NPT3/4NPT internal thread are optional); |
| weight | ≥1.65kg |
| Product Certification | Fire certification (mandatory CCCF), metrological certification CMC, explosion-proof certification CE、RoHS、 Third party metrology certification National patent product certification, three system certification: ISO9001, ISO14001, ISO18001 |
| Execution standards | GB 15322.1-2003, GB 3836.1-2010,GB 3836.2-2010, GB 3836.4-2010, GB 12476.1-2013, GB 12476.4-2010,GB 12476.5-2 013, JJF 1363-2012, JJF 1368-2012,JJF 1421-2013, JJF 1364-2012 |
| Standard accessory | Packaging box, instruction manual, certificate of conformity, warranty card, remote control (included), factory inspection report Installation bracket (optional), calibration cover (optional) |