| Technical Specifications |
| Model WD-T |
70112/24 |
10212/24 |
15224/48 |
20224/48 |
30224/48/96 |
35248/96 |
40248/96 |
50248/96 |
60248/96 |
70296 |
| rated power |
700W |
1000W |
1500W |
2000W |
3000W |
3500W |
4000W |
5000W |
6000W |
7000W |
| Peak power (20ms) |
2100W |
3000W |
4500W |
6000W |
9000W |
10500W |
12000W |
15000W |
18000W |
21000W |
| starter motor |
0.5HP |
1HP |
1.5HP |
2HP |
3HP |
3HP |
3HP |
4HP |
4HP |
5HP |
| Standard battery voltage |
12/24VDC |
12/24VDC |
24/48VDC |
24/48VDC |
24/48/96VDC |
48/96VDC |
48/96VDC |
48/96VDC |
48/96VDC |
96VDC |
| Machine size (L * W * Hmm) |
340x165x283 |
410x200x350 |
491x260x490 |
| Packaging size (L * W * Hmm) |
405x230x340 (1 unit)/475x415x350 (2 units) |
475x265x410 |
545x315x550 |
| Net weight (kg) |
9.5 |
10.5 |
11.5 |
17 |
20.5 |
21.5 |
29 |
30 |
31.5 |
36 |
| Gross weight (kg) |
11 |
12 |
13 |
19 |
22.5 |
23.5 |
32 |
33 |
34.5 |
39 |
| General Parameters |
| input |
DC input voltage range |
10.5-15VDC (single battery voltage) |
| Range of mains input voltage |
73VAC~138VAC / 145VAC~275VAC / 155VAC~285VAC / 165VAC~295VAC |
| Frequency range of mains power input |
45Hz~65Hz |
| Maximum mains charging current |
0A~20A (depending on the model) |
| Municipal power charging method |
Three stage (constant current, constant voltage, float charging) |
| output |
Inverter output efficiency |
≥85% |
| Inverter output voltage |
110VAC ± 2%/220VAC ± 2%/230VAC ± 2%/240VAC ± 2% (battery mode) |
| Inverter output frequency |
50Hz ± 0.5 or 60Hz ± 0.5 |
| Inverted output waveform |
pure sine wave |
| Efficiency of mains power output |
>99% |
| Output voltage range of mains power |
110VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10% |
| Frequency range of mains power output |
automatic tracking |
| Distortion degree of inverter output waveform |
≤ 3% (linear load) |
| Battery mode no-load loss |
≤ 2.5% rated power |
| No load loss in mains mode |
≤ 2% rated power (mains charger not working) |
| Energy saving mode no-load loss |
≤10W |
| Battery Type |
VRLA |
Uniform charging voltage: 14V; Floating charging voltage: 13.8V (12V system; 24V system x2; 48V system x4; 96V system x8) |
| Custom Battery |
Customized charging and discharging parameters for different types of batteries according to user requirements |
| protect |
Battery undervoltage alarm |
11V (voltage of a single battery) |
| Battery undervoltage protection |
10.5V (voltage of a single battery) |
| Battery overvoltage alarm |
15V (voltage of a single battery) |
| Battery overvoltage protection |
17V (voltage of a single battery) |
| Battery overvoltage recovery voltage |
14.5V (voltage of a single battery) |
| Overload power protection |
Automatic protection (battery mode), circuit breaker or fuse (mains mode) |
| Inverter output short circuit protection |
Automatic protection (battery mode), circuit breaker or fuse (mains mode) |
| Temperature protection |
>90 ° C (turn off output) |
| call the police |
A |
Normal working condition, no alarm sound from buzzer |
| B |
When there is a battery failure, abnormal voltage, or overload protection, the buzzer will beep 4 times per second |
| C |
When the machine is turned on for the first time and functioning normally, the buzzer will sound 5 times |
Built in Sun Capable of controlling (Optional) |
Charging mode |
PWM or MPPT |
| charging current |
10A~60A (PWM or MPPT) |
24/48V(PWM:10A~60A/MPPT:10A~100A) |
48V(PWM:10A~120A/MPPT:10A~100A) / 96V (50A/100A (PWM or MPPT)) |
| Photovoltaic input voltage range |
PWM: 15V-44V (12V system); 30V-44V (24V system); 60V-88V (48V system); 120V-176V (96V system) MPPT: 15V-120V (12V system); 30V-120V (24V system); 60V-120V (48V system); 120V-240V (96V system) |
Maximum photovoltaic input voltage (Under minimum conditions) |
PWM: 50V (12V/24V system); 100V (48V system); 200V (96V system)/MPPT: 150V (12V/24V/48V system); 300V (96V system) |
| Maximum photovoltaic input power |
12V system: 140W/280W/420W/560W/700W/840W/1120W/1400W/1680W; 24V system: 280W/560W/840W/1120W/1400W/1680W/2240W/2800W/3360W; 48V system: 560W/1120W/1680W/2240W/2800W/3360W/4480W/5600W/6720W; 96V system: 5.6KW/11.2KW |
| standby loss |
≤3W |
| Maximum conversion efficiency |
>95% |
| working mode |
Inverter priority/mains priority/energy-saving mode |
| Convert time |
≤4ms |
| panel display |
LCD |
| Communication function (optional) |
RS232/RS485 communication interface/mobile app (WIFI monitoring or GPRS monitoring) |
| environment |
Operating temperature |
-10℃~40℃ |
| Storage temperature |
-15℃~60℃ |
| noise |
≤55dB |
| altitude |
2000m (use with reduced rating if exceeded) |
| relative humidity |
0%~95%, no condensation |
| Note: Please contact the sales consultant to obtain the latest product specifications |