Welcome Customer !

Membership

Help

Jiangsu Zhuomai Instrument Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Jiangsu Zhuomai Instrument Co., Ltd

  • E-mail

    2028244444@qq.com

  • Phone

    17110656565

  • Address

    No. 15 Market Road, Gaojiayan Town, Huaiyin District, Huai'an City

Contact Now

Wall mounted external clamp ultrasonic flowmeter

NegotiableUpdate on 01/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The wall mounted external clip type ultrasonic flowmeter is an instrument that measures the flow rate of liquid inside a circular tube based on the principle of "velocity difference method". It adopts advanced multi pulse technology, signal digital processing technology, and error correction technology, making flow meters more adaptable to the environment of industrial sites, and measuring more conveniently, economically, and accurately.
Product Details

Wall mounted external clamp ultrasonic flowmeter Main technical parameters

* Measurement accuracy: superior to1

* Repeatability: superior to0.2%

* Measurement cycle:500ms (per second2Next, collect every cycle128group data)

* Working power supply:220VAC/8~36VDC

* Maximum flow rate:64m/s(Flow velocity resolution0.001m/s)

* Display:2×10Chinese character backlit LCD can display instantaneous flow rate, positive, negative, net cumulative flow rate, flow velocity, etc

* Operation:4×4Tap the keyboard lightly(F4Host magnetism4button)operation

* Signal input: ◇3road4-20mAAnalog input,precision0.1%,Can input signals such as pressure, liquid level, temperature, etc

2Road three line systemPT100rtd

* Signal output: ◇1Road isolationRS485output

   1road4-20mAor0-20mAoutput

1Road isolationOCT (pulse width6~1000msProgrammable between them, default200ms)

1Road relay output(pulse width200ms )

* Data storage: optional built-in data storage(SDcard)It can store time, instantaneous flow, cumulative flow, signal status, etc., and data can be imported into the computer through dedicated software for easy statistics and management

* Communication protocol:MODBUSagreement,M-BUSagreement,FUJIExtend the protocol and be compatible with communication protocols of similar products from other domestic manufacturers

* Other functions: ◇ Automatic memory before512Days ago128month10年正/negative/Net cumulative flow

◇ Before automatic memory30Next time, power outage time, and flow rate can be automatically or manually replenished, which can be achieved throughMODBUSProtocol Reading

Programmable batch (quantitative) controller with fault self diagnosis function

◇ Can be achieved throughemailThe transmitted code file implements software upgrade

* Protection level: SensorIP68F4hostIP68, other hostsIP65

* Explosion proof grade:EXdBT4 (JN-100F2type)

Wall mounted external clamp ultrasonic flowmeter

Technical Specifications

standardS1 type

standardM1型

standardL1 type

high temperatureS1H type

high temperatureM1H type

Applicable Pipe Diameter

DN15~DN100

DN50~DN700

DN300~DN6000

DN15~DN100

DN50~DN700

materialquality

ABS

Special high-temperature materials

operating frequency

1MHz

Installation method

V (N、W) 法

V. Z method

Z method

V (N、W) 法

V. Z method

Calibration

Whole machine pairing calibration

Magnetic

have

none

Applicable Temperature

0℃~70℃

0℃~160℃

Protection level

IP68 (capable of immersion operation, water depth ≤ 3 meters)

Overall dimensions

45×30×30

60×45×45

80×70×55

90×85×24

90×82×29

quality(g/pair)

75

250

650

94

150

medium type

A single, uniform, and stable liquid that can transmit ultrasonic waves, such as water, seawater, sewage, alcohol, and various oils.

Medium turbidity

≤ 20000ppm with low bubble content

Applicable pipes

Carbon steel, stainless steel, cast iron, copper PVC、 Aluminum, fiberglass and other uniformly dense pipelines are allowed to have lining.

Pipeline lining material

Epoxy asphalt, rubber, mortar, polypropylene, polystyrene, rubberwood, polytetrafluoroethylene, etc.

signal cable

SEYV75-2 special shielded cable, with a single cable that can be extended up to 300 meters. When wiring, the cable should be equipped with a metal sleeve to increase its resistance
Interference and be careful not to parallel cables with high-voltage cables, and try to avoid interference sources such as frequency converters.


Similar Product Recommend