Wall mounted external clamp ultrasonic flowmeter Main technical parameters:
* Measurement accuracy: superior to1%
* Repeatability: superior to0.2%
* Measurement cycle:500ms (per second2Next, collect every cycle128group data)
* Working power supply:220VAC/8~36VDC
* Maximum flow rate:64m/s(Flow velocity resolution0.001m/s)
* Display:2×10Chinese character backlit LCD can display instantaneous flow rate, positive, negative, net cumulative flow rate, flow velocity, etc
* Operation:4×4Tap the keyboard lightly(F4Host magnetism4button)operation
* Signal input: ◇3road4-20mAAnalog input,precision0.1%,Can input signals such as pressure, liquid level, temperature, etc
◇2Road three line systemPT100rtd
* Signal output: ◇1Road isolationRS485output
◇1road4-20mAor0-20mAoutput
◇1Road isolationOCT (pulse width6~1000msProgrammable between them, default200ms)
◇1Road relay output(pulse width200ms )
* Data storage: optional built-in data storage(SDcard)It can store time, instantaneous flow, cumulative flow, signal status, etc., and data can be imported into the computer through dedicated software for easy statistics and management
* Communication protocol:MODBUSagreement,M-BUSagreement,FUJIExtend the protocol and be compatible with communication protocols of similar products from other domestic manufacturers
* Other functions: ◇ Automatic memory before512Days ago128month10年正/negative/Net cumulative flow
◇ Before automatic memory30Next time, power outage time, and flow rate can be automatically or manually replenished, which can be achieved throughMODBUSProtocol Reading
Programmable batch (quantitative) controller with fault self diagnosis function
◇ Can be achieved throughemailThe transmitted code file implements software upgrade
* Protection level: SensorIP68,F4hostIP68, other hostsIP65
* Explosion proof grade:EXdⅡBT4 (JN-100F2type)
Wall mounted external clamp ultrasonic flowmeter
Technical Specifications |
standardS1 type |
standardM1型 |
standardL1 type |
high temperatureS1H type |
high temperatureM1H type |
Applicable Pipe Diameter |
DN15~DN100 |
DN50~DN700 |
DN300~DN6000 |
DN15~DN100 |
DN50~DN700 |
materialquality |
ABS |
Special high-temperature materials |
|||
operating frequency |
1MHz |
||||
Installation method |
V (N、W) 法 |
V. Z method |
Z method |
V (N、W) 法 |
V. Z method |
Calibration |
Whole machine pairing calibration |
||||
Magnetic |
have |
none |
|||
Applicable Temperature |
0℃~70℃ |
0℃~160℃ |
|||
Protection level |
IP68 (capable of immersion operation, water depth ≤ 3 meters) |
||||
Overall dimensions |
45×30×30 |
60×45×45 |
80×70×55 |
90×85×24 |
90×82×29 |
quality(g/pair) |
75 |
250 |
650 |
94 |
150 |
medium type |
A single, uniform, and stable liquid that can transmit ultrasonic waves, such as water, seawater, sewage, alcohol, and various oils. |
||||
Medium turbidity |
≤ 20000ppm with low bubble content |
||||
Applicable pipes |
Carbon steel, stainless steel, cast iron, copper PVC、 Aluminum, fiberglass and other uniformly dense pipelines are allowed to have lining. |
||||
Pipeline lining material |
Epoxy asphalt, rubber, mortar, polypropylene, polystyrene, rubberwood, polytetrafluoroethylene, etc. |
||||
signal cable |
SEYV75-2 special shielded cable, with a single cable that can be extended up to 300 meters. When wiring, the cable should be equipped with a metal sleeve to increase its resistance |
||||