Winner2006 fully automatic wet laser particle size analyzer

NegotiableUpdate on 12/10
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Winner2006 fully automatic wet laser particle size analyzer is an upgraded product of Winner2005, which has opened up a new field of wide distribution particle testing. By adopting advanced testing principles, * * calculation modes, and * * calibration methods, this instrument has outstanding advantages such as accurate test results, good test repeatability, and high resolution, making it the * * choice for wide distribution particle size testing.
Product Details

Winner2006 fully automatic wet laser particle size analyzerProduct Features

(1) Imported semiconductor fiber laser is used as the main light source. This light source uses a single film optical fiber, which has reliable performance, compact structure, long lifespan, maintenance free, high electro-optical conversion efficiency, and maintains consistent beam divergence angle and beam quality throughout the full power range.

(2) The entire optical path uses only one lens. The traditional optical path generally consists of a reflector, a beam expander, and a Fourier mirror. Winner2006 only retains one Fourier mirror, which provides better beam quality and easier maintenance in the later stage.

(3) The main detector adopts the newly designed TD41 detector, which maximizes the testing lower limit of the main detector and can seamlessly connect with the auxiliary detector, overcoming the problem of inaccurate testing at the junction of the main detector and the auxiliary detector.

(4) The auxiliary detector adopts a Japanese imported photodetector with filtering, and uses circuit board integrated molding technology in the arrangement to better improve the testing accuracy of small particles.

(5) More precise optical alignment technology has added a limit function on the basis of improving alignment accuracy, effectively improving alignment speed and preventing mechanical failures caused by misoperation.

(6) In order to ensure that the testing limit of this instrument reaches 1000 microns, a larger flow circulation pump is used, effectively solving the problem of pump body wear.

(7) We have adopted a simpler and more convenient clamp valve as the drainage valve of the instrument. This valve can replace pipelines of different materials to achieve anti-corrosion design.

Winner2006 fully automatic wet laser particle size analyzerTechnical Specifications:

Specification Model

Winner2006A

Winner2006B

execution standard

ISO13320:2009,GB/T19077-2016,Q/0100JWN001-2013

test scope

0.01-1000μm

0.1-1000μm

Number of detector channels

90

87

Accuracy error

Less than 0.5%(D50 value of national standard sample)

repeatability error

less than0.5%(D50 value of national standard sample)

Laser parameters

Main laser source: semiconductor fiber laser, λ=636.5nm, p>2mW

Auxiliary laser source: semiconductor laser, λ= 532nm,p>2mW

Dispersion method

ultrasound

Frequency: f=40KHz, power: p=60W, adjustable time

stir

Speed: 0-3000rpm, adjustable speed

loop

Rated flow rate: 10L/min Rated power: 15W

sample pool

Capacity: 450mL

Operation Mode

Software operation/fully automatic operation mode can be switched

Automatic centering system

Fully automatic centering system

Software features

analysis mode

Including free distribution, R-R distribution, lognormal distribution, and hierarchical statistical models, it meets the different requirements of different industries for the statistical methods of particle size of the tested samples.

statistical method

Volume distribution and quantity distribution to meet different statistical methods for particle size distribution in different industries.

Statistical comparison

Statistical comparative analysis can be conducted on multiple test results, which can significantly compare the differences in test results between different batches of samples, samples before and after processing, and at different times. This has strong practical significance for industrial raw material quality control.

Custom analysis

User defined analysis parameters, calculated as percentages based on particle size, percentages based on particle size, or percentages based on particle size ranges, to meet the characterization requirements of different industries for particle size testing.

Test Report

The test report can be exported in various forms such as Word, Excel, images (Bmp), and text (Text), meeting the needs of viewing test reports in any situation and citing test results in scientific research articles.

Multi language support

Chinese and English language interfaces are supported, and other language interfaces can also be embedded according to user requirements.

Intelligent operation mode

Equipped with intelligent operation mode, it can automatically control the steps of water inlet, dispersion, testing, etc., which not only reduces the workload of testing personnel, but also improves the repeatability of test results due to no human interference.

test speed

<2min/time

volume

850mm*390mm*450mm

weight

40Kg