Welcome Customer !

Membership

Help

Yangzhou Jiangdu District Kaiyuan Experimental Machinery Factory
Custom manufacturer

Main Products:

ybzhan>Products

Yangzhou Jiangdu District Kaiyuan Experimental Machinery Factory

  • E-mail

    305456145@qq.com

  • Phone

  • Address

    Binhu Farmers' Street, Zhenwu Town, Jiangdu District, Yangzhou City

Contact Now

Wire twisting and winding test machine, metal wire twisting and winding test machine, wire and cable winding test machine. Product keywords: metal wire winding test machine; Metal wire twisting and winding testing machine

NegotiableUpdate on 03/23
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Wire twisting and winding test machine, metal wire twisting and winding test machine, wire and cable winding test machine. Product keywords: metal wire winding test machine; Metal wire twisting and winding testing machine
Product Details

1、 Overview of the main unit of wire winding and torsion testing machine
The wire winding and twisting test machine is suitable for the GB4909.4-2009 "Bare Wire Test Method - Twisting Test" and GB4909.7-2009 "Bare Wire Test Method - Winding Test" standards, and is used in situations where aluminum wire, steel wire, and copper rod need to undergo winding and twisting tests. It is an essential testing tool for steel cored aluminum wire manufacturers.
2、 Main technical parameters:
Twist: 1. Dimensions: 1440mm × 390mm × 1080mm
2. Input voltage: 380V
3. Input power: 1.5KW
4. Twist adjustable range: 10 revolutions per minute, 30 revolutions per minute, 60 revolutions per minute
5. Twisting range: (1) Copper rod: ¢ 8mm
(2) Aluminum pole: ¢ 6mm
(3) Steel wire: ¢ 4.2mm
Winding: 1. Test diameter: Aluminum wire: ¢ 1.25mm - ¢ 6.0mm
Steel wire: ¢ 1.25mm - ¢ 3.8mm
Copper wire: ¢ 0.3mm - ¢ 8.0mm
2. Core rod diameter: ¢ 1.25mm - ¢ 19mm
3. Right axle head displacement distance: ≥ 40
4. Spindle speed: 10 revolutions per minute


3、 Sample collection
According to the requirements of GB4909.4-2009, there shall be no mechanical damage on the surface of the specimen, and the specimen shall be calibrated.
Sample length=effective length+clamping length
Effective length: determined based on the diameter of the sample and the standard.
Clamping length: The clamping length of two clamps is generally about 60-70mm