E-mail
yuhangzhida@126.com
-
Phone
13412317138
-
Address
Building A, Songyuan Innovation Technology City, No. 126 Junda West Road, Dongkeng Town, Dongguan City
Aerospace Zhida Test Equipment (Dongguan) Co., Ltd
yuhangzhida@126.com
13412317138
Building A, Songyuan Innovation Technology City, No. 126 Junda West Road, Dongkeng Town, Dongguan City






Xenon lamp aging test chamber reference standard:
Xenon lamp aging test chamber according to GB/T2423.24-95 Environmental Testing Part for Electronic and Electrical Products:
Test method, test SQ: simulate the production of solar radiation on the ground;
满足: GB/T9344-98、GB/T2424.14-95
GB/T8427-89 Textiles - Color fastness test - Xenon arc color fastness to artificial light
GB/T8430-98 Textiles - Color fastness test - Xenon arc color fastness to artificial light
GB/T1865-97 Paints, Varnishes, Artificial Climate Aging, and Artificial Radiation Exposure
GB/T16422.2-1999 Plastics Laboratory Light Source Exposure Test Method (Part: Arc Xenon Lamp)
studio dimensions
Depth x Width x Height 950 x 950 x 850mm
Total power 6.5KW
Box structure shell
A3 steel plate, spray treated, with a color of computer color inlaid with gray
inner liner
SUS304 mirror stainless steel plate
sample holder
The rotation mode of the sample rack is 1 rpm, which can suspend the specimen and the distance between the suspension point of the specimen and the xenon lamp can be adjusted; Sample placement method, suspension method, with no less than 10 test samples per test, each sample weighing ≥ 5Kg and diameter ≥ 400mm
Radiation system light source
3KW air-cooled full spectrum lamp tube, with a service life of over 1000 hours
Light source toggles
Fully electronic automatic trigger, trigger time<2S
The interval between secondary triggers is greater than 10 minutes
Light source power supply
Current feedback constant current system (multifunctional protection against overheating and overload)
Radiation measurement
Light intensity radiometer
radiation intensity
(550 ± 5) W/m2, (1000 ± 5) W/m2 (optional)
spectral wavelength
290nm~800nm
filtration system
Combining the characteristics of infrared, ultraviolet, and window glass, two specially designed optical filter glasses are used to simulate indoor and outdoor solar radiation environments. They can be manually replaced and have a service life of over 1000 hours.
Temperature Control System
temperature range
RT~80 ℃, uniformity: ± 2.5 ℃, fluctuation: ± 1 ℃
temperature sensor
Platinum resistance PT100Ω/MV
Heating method
Nickel chromium alloy electric heating heater
blackboard temperature
65 ℃ (deviation ± 3 ℃), real-time control directly set on the control panel, blackboard thermometer: non insulated blackboard BPT
Humidification system
humidity range
Optical cycle 30% to 80%; Dark cycle can reach 98%
Humidifier tube
Stainless steel electric humidification tube
Humidification water storage tank
SUS304 stainless steel humidification water storage tank with automatic water level control
Humidifier box
SUS304 stainless steel humidification box
Humidification method
Steam humidification
humidity sensor
Dry wet bulb type
sprinkler system
Spray time
Adjustable spray pipe for 1 minute to 999 hours (on/off)
Stainless steel nozzle
Nozzle aperture 0.4mm
Spray pressure 78-127kpa
spray pump
High pressure pressurized spray water pump
Spray water storage tank
SUS304 stainless steel spray water storage tank, equipped with automatic water level control device
Dark cycle
Adjustable from 10 minutes to 999 hours (bright, dark)
power supply
AC 380V 50HZ
turret
360 ° rotation at a rate of 1r/min (sample is a 75 × 150 standard plate)
control system
Controller LCD touch screen controller
Set precision temperature ± 0.1 ℃, humidity ± 1% R.H
Set display range humidity: 0-100% RH, time: 0-999h59min
Cooling system compressor
Fully enclosed French Taikang
Refrigerant R404A
Condensation method: air-cooled
Other configurations
Door frame insulation
Silicone rubber door sealing strip resistant to high and low temperature aging
Standard Configuration
1 set of anti radiation glass window, 1 xenon lamp tube, 1 set of filter glass
Random materials
Instructions, circuit diagrams, operating methods, precautions, basic shipping accessories, maintenance and repair matters
protection system
Power overload and short circuit protection
grounding protection
overtemperature protection
Control circuit overload and short circuit protection
Water shortage alarm
Alarm sound prompt
Overload and overpressure protection for refrigeration system
Usage environment
Environmental temperature 5 ℃~28 ℃ (average temperature within 24 hours ≤ 28 ℃)
Environmental humidity ≤ 85% RH