1、 Product Overview
YES8090Cable pathdetectorAlso known as a pipeline instrument or path detector, it is a highly comprehensive path detection instrument. havePipeline path detection, cable identification, fault findingWaiting for multiple functions. The instrument is composed ofTransmitter, transmission current clamp, receiver、Receive flexible current clamps, connect test wiresACharacter frame (optional))Waiting for composition.
YES8090Cable pathdetectorIt can be done without excavation,Used for path detection, pipeline survey, and depth measurement of metal pipelines and underground cables.The instrument uses multiple filtering techniques, has anti-interference ability, and can accurately locate and depth. It is suitable for detecting and patrolling various underground metal pipelines, pipeline management and maintenance, municipal planning and construction, power supply and other departments' pipeline detection. This function is achieved by coordinating the signal transmitter, receiver, signal transmission clamp, and connection test line.
2、 Productfeature
1、Multiple detection modes: classic positioning mode, wire cruise mode, signal distortion measurement mode;
2、Classic positioning mode: compass, direction, and signal amplitude display, visually showing the left and right directions of the pipeline.
3、Wire cruise mode:360Pipeline path indication, continuously displaying depth, current, and relative position of the pipeline. The interface is simple and intuitive, and can be operated without experience
4、Signal distortion measurement mode: Simultaneously display peak and valley waveforms,In a distortion free site, the peak and valley positions should be consistent, and the site shape should be symmetrical relative to the centerline.
5、Current direction determination (partial frequency) can be achieved by calibrating the current direction, eliminating adjacent line interference, and preventing tracking errors.
6、Fully digital high-precision sampling processing: stable and reliable, ultra-high sensitivity, extremely narrow receiving bandwidth, strong anti-interference ability, can fully suppress the power frequency and harmonic interference of adjacent operating cables and pipelines.
7、Multiple detection frequencies:11Active detection frequency and3Passive detection frequency.
8、The transmitter has multiple signal output methods: direct connection output, clamp coupling, and induction method.
9、Digital amplification power output of transmitter, fully automatic impedance matching, fully automatic protection.
IIItechnologyparameter
Receiver specifications
merit can |
Pipeline detection (cable position tracking, direction display, depth measurement, current measurement), cable identificationATroubleshooting of Character Frame (Optional Function)) |
electricity source |
8.4VLarge capacity rechargeable lithium battery |
input method |
Built in receiving coil, flexible caliperACharacter frame (optional function)) |
reception frequency |
Active detection frequency:640HzThe1.28kHzThe2.56kHzThe3.20kHzThe4.09kHzThe8.19kHzThe10.2kHzThe32.7kHzThe65.6kHzThe81.9kHzThe197kHz Passive detection frequency of power frequency:50HzThe60HzThe250Hz RF passive detection frequency band: The center frequency is divided into32.7kHzThe65.6kHzThe81.9kHzThe197kHz |
Pipeline detection mode |
Wide peak method, narrow peak method, valley method |
Pipeline detection display |
Classic positioning mode, wire cruise mode,Signal distortion measurementpattern |
|
Pipeline detection Testing Scope |
Direct connection method: generally can reach the length of the cable0~20Kilometers are mainly determined by grounding resistance, cable resistance, and cable burial depth Coupling method: generally can reach the length of the cable0~10Kilometers are mainly determined by grounding resistance, cable resistance, and cable burial depth Induction method: suitable for buried depths less than2mThe cable |
Depth and Current |
Real time display of cable depth and current value |
Pipeline measurement depth |
0-20m |
Depth accuracy |
Accurate positioning accuracy of plane position: The central axis position of the target cable or pipeline: ±5%(Buried deep inside)0-3m)-10%(Buried deep inside)3m-20m) |
True or False Reminder |
Excluding interference from adjacent cables, when measuring adjacent cables, the measurement of adjacent cables can be distinguished based on the different signal strengths and measured current phases feedback from adjacent cables. During the process of tracking cables, observe the phase dial and pointer direction to distinguish between the measured cable and adjacent cables |
Sound indication |
Frequency modulation tones that vary with signal strength |
anti-interferencedisplay |
Green: No interference Green: Good (results are reliable) Red: Serious interference (results are unreliable) |
anti-interference capability |
Extremely narrow receiving frequency band, unique digital processing method, can fully suppress the power frequency and harmonic interference of adjacent operating cables and pipelines |
Interference distance |
When using coupling and induction methods, the transmitter will generate interference at close range, and the distance of interference is related to the transmission power and frequency. The higher the power and frequency, the stronger the interference. The minimum distance at which a receiver is not affected by transmitter interference often needs to be experimentally determined: Pipeline detection: coupling method5mIn addition, induction method20mIt can be confirmed that there is no interference outside Cable identification: coupling method2~5mIt can be confirmed that there is no interference outside |
Cable identification |
Identification method: intelligent identification of flexible calipers; Number of cables that can be calibrated:1~20Article; Calibration value: The percentage of current between the received signal and the transmitted signal is at the calibration value75%~135%One of the conditions for successful identification is between them; Directionality: The direction of the transmitting clamp, receiving clamp, and loading signal must be consistent, which is one of the conditions for successful recognition |
|
Cable identification Testing Scope |
Direct connection method: The identifiable circuit resistance is0Oh!8kΩ signal(Generally, it can reach the length of the cable0~20Kilometers are mainly determined by grounding resistance and cable resistance) Coupling method: The identifiable circuit resistance is0Oh!1kΩ signal;(Generally, it can reach the length of the cable0~6Kilometers are mainly determined by grounding resistance and cable resistance) |
liquid crystal |
4.3inchLCDColor screen LCD (high brightness screen), visible under sunlight |
touch touch |
Yes, capacitive touch |
ruler inch |
about350mm(long)×155mm(wide)×700mm(tall) |
quality quantity |
about2kg |
connection interface |
Type-C USBInterface, aviation socket |
Inner diameter of coil |
φ200mm(Larger caliber can be customized as needed) |
Working temperature and humidity |
-10℃~40℃;80%Rhbelow |
Storage temperature and humidity |
-10℃~50℃;≤95%RH,no condensation |
endure press |
AC2000V/rms(Before the front and rear ends of the shell) |
Suitable for safety regulations |
IEC61010-1 CATⅢ600V,IEC61010-031,IEC61326Pollution level2 |
Transmitter specifications
merit can |
Multiple frequency signal transmission methods |
electricity source |
10.8VLarge capacity rechargeable lithium battery |
output method |
Direct connection method, coupling method, induction method |
output frequency |
640Hz,1.28kHz,2.56kHz,3.20kHz,4.09kHz,8.19kHz,10.2kHz,32.7kHz,65.6kHz,81.9kHz,197kHz |
output mode |
Automatic recognition, automatically identifying based on different accessories |
output power |
15W max,9Adjustable files |
block resist |
Fully automatic real-time impedance matching and protection function |
Directly connected output voltage |
150Vpp max |
Circuit protection |
Equipped with overload and short circuit protection |
liquid crystal |
5inchLCDColor screen LCD |
touch touch |
Yes, capacitive touch |
instrument size |
about320mm(long)×275mm(wide)×145mm(tall) |
quality quantity |
The transmitter is approximately3.85kg; Launch clamp about1.18kg |
charger |
DC 11.1V 3A |
Launch clamp size |
length, width, thickness297mm×194mm×39mm |
Launch caliper inner diameter |
φ125mm |
Launch clamp wire length |
3m |
test line |
Red test line3mThe black test line3m |
connection interface |
USBInterfaceDCInterface, aviation socket |
resist press |
The transmitter adopts an integrated specialized toolbox design, and the box can withstand about200kgThe pressure |
endure press |
AC 3700V/rms(Before the top and bottom of the instrument box) |
electromagnetic properties |
IEC61326(EMC) |
Suitable for safety regulations |
IEC61010-1(CATⅢ300VTheCAT IV 150VPollution level2) |