Yifumen IFM pressure sensor AC1147 with display screen

NegotiableUpdate on 12/23
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Yifumen IFM pressure sensor with display screen AC1147 $r $n pressure sensor with display screen PN-010-RER14-QFRKG/US//V two switch outputs, one of which has IO Link communication interface red/green display, used to clearly identify acceptable range. Pipeline connections can be rotated for easy arrangement, high load protection, long-term stability and sturdy design, suitable for harsh industrial environments
Product Details

Yifumen IFM pressure sensor AC1147 with display screen

IFM offers a wide range of electronic pressure sensors to meet the needs of various industrial applications. All devices are equipped with sturdy casings and do not require moving parts such as pistons or springs. They have excellent impact and vibration resistance, and will not experience any wear or maintenance. Pressure sensor/vacuum sensor - with digital display PN/PE
Clear indication of acceptable range: programmable red/green display
The pipeline connection can be rotated for convenient arrangement
Intuitive and user-friendly operation
Clearly indicate the switch status
Clear laser engraved labels
Pressure sensor with display screen
PN-010-RER14-QFRKG/US/ /V
Two switch outputs, one with IO Link communication interface
Red/green display, used to clearly indicate the acceptable range
The pipeline connection can be rotated for convenient arrangement
High load protection, long-term stability
Durable design, suitable for harsh industrial environments
Product features
Environmental temperature [° C] -25... 80
Storage temperature [° C] -40... 100
Shell protection level IP 65; IP 67
Output signal switch signal; IO-Link; (configurable)
Measurement range -1... 10 bar -14.5... 145 psi -0.1... 1 MPa
System interface threaded connection G 1/4 internal thread
application
Special performance gold-plated contacts
Ceramic capacitive pressure measuring element
Application for industrial use
Liquid and gas media
Medium temperature [° C] -25... 80
Blasting pressure small value 150 bar 2175 psi 15 MPa
Compressive strength 75 bar 1087 psi 7.5 Mpa
Vacuum resistance [mbar] -1000
Relative pressure; vacuum
Electrical data
Working voltage [V] 18... 30 DC; (Complies with EN 50178 SELV/PELV standard)
Current loss [mA]<35
Insulation resistance small value [M Ω] 100; (500 V DC)
Protection level III
Reverse phase protection is available
Startup delay time [s]<0.3
Watchdog Integrated Watchdog Circuit
Overall input/output
Total number of inputs and outputs, number of digital outputs: 2
output
Output quantity 2
Output signal switch signal; IO-Link; (configurable)
Electrical Design PNP/NPN
Number of digital outputs 2
Output function normally open/normally closed; (Parameters can be set)
Switching output DC voltage drop large value [V] 2.5
Continuous current load with switch output DC
[mA] 150; (200 (...60 °C) 250 (...40 °C))
Switching frequency DC [Hz]<170
Short circuit protection is available
Short circuit protection type pulse
Overload protection is available
Accuracy/Deviation
Switching point accuracy [% of measurement range value]<± 0.5
Repetitive accuracy [% of measurement range value]<± 0,1; (Temperature fluctuation<10 K)
Characteristic curve deviation [% of measurement range value]<± 0.25 (BFSL)/<± 0.5 (LS); (BFSL=Best Fit Straight Line; LS=Limit Point Setting)
Lag deviation [% of measurement range value]<± 0.25
Long term stability [% of measurement range value]<± 0.05; (Every 6 months)
Zero point of temperature coefficient
[Percentage of measurement range value/10 K]<± 0.2; (0...80 °C)
Temperature coefficient range<± 0.2; (0...80 °C)
reaction time
Reaction time [ms]<3
Programmable delay time dS, dr [s] 0... 50
Software/Programming
Parameter setting delay/window; Normally open/normally closed; Output polarity; ON delay, turn off delay; Damping; display unit
interface
IO Link communication interface
Transfer type COM2 (38,4 kBaud)
Required mate port type A; (When pin 2 is not connected: B)
Borkhov P2000
Pasfeta/PULSAFEDER LPH6MB-PTC3-XXX
KSO-G02-2CB-20
KSO-G02-2CB-30
Handheld device 04230-A-1001
Handheld connector 04230-A-1025
Inverter \ \ \ ACS510-01-246A-4 \ \ 450VAC \ \ 250A
Double acting valve positioner, AVP301-RSD3A Shanwu
PMP21-BB1U1RBWJJ
AW20-02BG-B
AW20-02BG-A
SY7120-5DZD-02
SY7120-4DZ-02
SY5140-5FU-Q
Detection switch PRK5/4P-M8
P-GC,SH,4201-6-3C
GC-12Z-6-3C-LIV filter cartridge
Zd600pct3
CDQ2A80-30DMZ-XC2
CDQ2A80-75DMZ-XC2
AR60K-10
ZH10BS-06-06
SY5120-5YO-C6F-Q
SY5120-5DZ-01
D-M9B
SY3120-5G-M5-F2
VNC211A-15A-5DZ
German BURKERT solenoid valve 00043129
XD2PA22CR
55B-12-PI-121CA
VQ5201-41
Yifumen IFM pressure sensor AC1147 with display screen


Similar Product Recommend