| Project Content | Specific parameters | |
| Product Name: | ZCA200-HCL online hydrogen chloride detector | |
| measuring range | 0-20ppm、50ppm、100ppm、200ppm、500ppm、1000ppm | |
| (Range not listed, please consult customer service) | ||
| divide distinguish rate | 0.01ppm,0.1ppm,1ppm | |
| Accuracy | ≤± 3% FS (normal accuracy); ≤± 1% FS (high precision) | |
| weight repeated sexually | ≤±1% | |
| response time | T90 Determined by sensor characteristics | |
| recovery time | T90-T10 determined by sensor characteristics | |
| Display mode | Instrument panel display interface | |
| Visible distance | ≥ 10 meters (5.0 visual acuity) | |
| system language | Chinese (default) and English are switchable | |
| Direct reading | Measurement value, alarm value | |
| operating mode | Remote control+four key operation | |
| MODE | There are two operation modes to choose from: user mode and administrator mode | |
| detection | Diffusion type, pipeline type, flow type, pump suction type. | |
| For more details, please consult customer service. | ||
| Data Download | Support RS485 serial port measurement data download | |
| calibration | Target point calibration function, adjustable calibration values, one click zero adjustment | |
| Sampling method: | Free diffusion type - online continuous detection, free diffusion type detection method; | |
| Inhalation type - external air pump can be equipped with a flow type adapter for inlet and outlet or an internal air pump to achieve pump suction detection (air pump optional) | ||
| Installation method | Wall mounted; Pipeline type (divided into holding tube type and inserting tube type, pipeline type external thread: M45X1.5mm, optional pipeline adapter screw joint, weldable); | |
| For more information, please consult the manufacturer | ||
| Shell material | Shell: ADC12 aluminum alloy, sturdy, wear-resistant and corrosion-resistant (optional 316 stainless steel shell) | |
| Adopting high-strength wear-resistant and corrosion-resistant aluminum profiles, sturdy and durable (optional 316 stainless steel air chamber), with M45 * 1.5 external thread for the air chamber; | ||
| Explosion proof sign | Ex d II CT6 Gb | |
| Explosion proof certificate number: CNEx15.3049 National Explosion proof Electrical Product Quality Supervision and Inspection Center Inspection and Certification | ||
| protection grade | IP65 | |
| operation temperature | -40 ℃~70 ℃ (ordinary catalytic combustion principle sensor) | |
| -40 ℃~270 ℃ (special catalytic combustion) | ||
| -40 ℃~50 ℃ (electrochemical) | ||
| -20 ℃~50 ℃ (PID principle sensor) | ||
| -20 ℃~50 ℃ (infrared/fluorescence gas sensor) | ||
| -40 ℃~70 ℃ (thermal conductivity principle sensor) | ||
| -40 ℃~750 ℃ (Zirconia principle oxygen sensor) | ||
| Working humidity | 10%~95%RH, No condensation (humidity>90% RH, optional filter for condensation) | |
| (For higher temperature and humidity detection environments, you can choose our pre treated gas monitoring system.) | ||
| Working pressure | 0.08~0.6MPa (thermal conductivity principle sensor) | |
| 0.02-0.36MPa (Zirconia principle oxygen sensor) | ||
| 86-106KPa (Other) | ||
| Signal transmission method | Three core (four core) shielded cable transmission: can transmit up to 1000 meters to 2000 meters (single core 1 square shielded cable); | |
| Current signal 4-20mA output, can be connected to alarm controller PLC、DCS Waiting for various control systems (standard configuration) | ||
| Frequency signal output of 200-1000Hz (optional function) | ||
| GPRS wireless transmission: no distance limit, built-in module, transmitted through mobile, China Unicom or telecom signals, with SMS reminder notification function (optional); | ||
| Other special transmission methods can be customized; | ||
| work consume | Electrochemical sensor: P ≤ 2.6W | |
| Conventional catalytic sensor :P ≤ 3.9W | ||
| Low power catalytic sensor :P ≤ 2.8W | ||
| thermal conductivity sensor :P ≤ 2.9W | ||
| Infrared sensor: P ≤ 3.0W | ||
| PID sensor: P ≤ 2.8W | ||
| Sound and light alarm, optional sound and light alarm, alarm sound:< 90 decibels | ||
| Alarm method | Panel LED alarm; | |
| Display screen character flashing and information reminder | ||
| 2 sets of relay outputs; | ||
| Alarm point setting | K1 alarm value, K2 alarm value; Can be set by oneself | |
| control output | Fan, valve, sound and light alarm | |
| Protection function | Lightning and surge protection design, wiring fault tolerance design, intermittent detection, sensor automatic protection function | |
| service life | 2 years (sensors), 5 years (instruments) | |
| Power supply | 12-35VDC, Typical power supply 24VDC | |
| size | 180mm in height, 140mm in width, and 92mm in thickness | |
| weight measure | ≥1.65kg | |
| Product Certification | Fire certification (mandatory CCCF) | |
| ATEX | ||
| Third party metrology certification | ||
| National Patent Product Certification | ||
| ISO9001 | ||
| Execution standards | GB15322.1-2003 | |
| GB3836.1-2010 | ||
| GB3836.2-2010 | ||
| Standard accessory | Packaging box, instruction manual, certificate of conformity, warranty card, factory inspection report | |
| Remote control (included), calibration cover (optional) | ||
◆ Original imported high-performance sensors with high measurement accuracy, good repeatability, and a service life of 2-5 years or more;
Adopting an independent 16 bit AD chip and a 4-layer circuit board design, it has stronger resistance to weak signals and interference;
◆ Equipped with an infrared remote control, menu operations can be performed through the remote control, which can achieve cover free operation in dangerous situations;
Intelligent temperature, humidity, and zero point compensation algorithms, with full software automatic calibration function to ensure the accuracy of measurement results; Automatically detect the working status of various sensors and components upon startup;
The dashboard display interface design features beautiful and elegant readings, reflecting humanized detail design;
Clear background light can display measurement information under any lighting conditions;
The friendly user interface with 4-point navigation showcases the humanized and international design;
◆ White, orange, and red backlight design, indicating normal and alarm status at a glance;
Multiple units including mg/m3, ppm, VOL, and LEL are available for selection;
◆ Equipped with an embedded 32-bit ultra-low power processor and unique signal processing algorithms, it has fast response speed and stability;
◆ Automatic protection function against high concentration gas impact, with factory reset settings to prevent misoperation;
The instrument is equipped with an infrared remote control, which can be operated through the remote control without opening the cover, making it simple and convenient;
◆ Three wire system with 4-20mA, RS485, 200~1000HZ signal output options, relay output, data recovery, data storage and other functions;
Two cable entry ports for easy on-site installation;
◆ Independent chamber structure, easy sensor replacement, no need for on-site calibration;
◆ First class mechanical design, the air chamber adopts high-strength aluminum profiles of military quality, which are wear-resistant, corrosion-resistant, and suitable for complex and harsh industrial environments. The reasonable and scientific air chamber design ensures the accuracy of real-time monitoring by sensors;
Explosion proof grade is Exd II CT6, certified by the National Explosion proof Electrical Inspection Center;
◆ Zero point automatic calibration: For certain environmental applications, the instrument can achieve zero point automatic calibration function;
◆ Self diagnostic function. The detector can monitor the working status and performance of its key hardware (key point voltage, signal, etc.);
Bilingual operating system: capable of switching between Chinese and English systems;
Infrared remote control operation mode. Adopting a user-friendly infrared remote control operation mode. No need to open the lid under any circumstances to ensure safe use in flammable and explosive environments.