Main characteristics and technical parameters of magnetic sensitive electronic dual color liquid level gauge
Date: 2020-04-13Read: 8

Magnetic sensitive electronic dual color liquid level gaugeMain features and technical parameters:

Magnetic sensitive electronic dual color liquid level gaugeWidely used in various industries such as steel, petroleum, chemical, oil field, medicine, food, and wine industry for liquid level measurement and display in storage tanks, tanks, tanks, reaction tanks, fermentation tanks, oil fields, liquid ammonia, strong acid and alkali liquids, weak acid and alkali liquids, boiler steam drums, deaerators, drainage tanks, swirl wells, water and air shafts, hydraulic production, desulfurization tanks, water cooling towers, furnaces, sterilization pots, return water tanks, high and low heaters, heaters, condensers, evaporators, and other pressure vessels and 304, 304 lined PTFE, 316L, PVC, PP compatible liquid media. There are multiple installation forms for you to choose from. To meet the requirements of different occasions and environments.

Key Features:

1. Steam red and water green, clear display, large observation angle, and long visible distance.

2. The body is made of high-quality stainless steel, and the liquid level gauge display device does not come into contact with the medium inside the container, with no leakage. It is suitable for use in Class I, II, and III pressure vessels. And ensure the safety and reliability of containers containing flammable, toxic, and corrosive media.

3. Large display range, high design pressure, and wide range of applications.

4. The sealing surface reduces leakage points by 95% compared to traditional glass level gauges, overcoming weak links such as running, emitting, dripping, and leaking in the connection between pressure vessels and level gauges in industries such as petroleum, chemical, and pharmaceutical.

5. Users can remotely display the liquid level without transmission at 1:1, 1:2, 1:4 if needed; Can output 4-20mA standard signal to achieve remote display of liquid level and centralized monitoring and control of liquid level in container groups; It can also achieve automatic water level adjustment and interlock protection.

Technical Specifications:

1. Vertical installation: (maximum deviation ≤ 30);

2. Measurement range: 0-150-6000mm (orders can be negotiated for sizes greater than 6000mm);

3. Medium density: 0.4-2.0g/cm<;

4. Working temperature: -50--400 ℃;

5. Follow speed: ≤ 0.08m/s;

6. Float material: 304, PTFE/304 Outer Village PTFE, aluminum, titanium;

7. LED display: low brightness type, high brightness type, and foggy diffuse type are available for selection;

8. Main pipe material: 304; 1Cr18Ni9Ti; 316L; 304 lined with PTFE; Titanium; PP; PTFE (polytetrafluoroethylene)

9. Connection flange: DN15~DN50 (HG20592-97 flange standard), the connection flange standard for high-pressure side mounted liquid level gauge adopts HG20595-97 butt welding with force;

10. Flange material: carbon steel, 304, 316L

11. Power supply voltage: DC24V, AC36V, AC220V;

12. Accuracy: ≥ 10mm;

13. Work pressure: -0.1 to 10 MPa;

14. Environmental vibration: frequency ≤ 25Hz, amplitude ≤ 0.5mm;

15. Medium viscosity: ≤ 0.4Pa. S;

16. Discharge valve: stainless steel ball valve, needle valve

Main pipe diameter: ¢ 48, ¢ 57, ¢ 62mm.

Additional feature selection:

Magnetic limit switch:

1. Normally open: closed above the alarm point;

2. Normally closed type: higher than alarm disconnection;

3. Switch capacity: 250VAC 1A (resistive) 250VAC 0.3A;

4. Switch lifespan: 1 × 105 cycles;

5. Liquid level transmitter: output current: 4-20ADC (two-wire system);

6. Resolution: ± 1cm;

7. Load resistance: 500 Ω (when powered by 24VDC);

8. Transmission distance: 3000m;

9. Working power supply: 12-36VDC;

Intelligent liquid level transmitter:

1. Output type: 4-20mADC;

2. Resolution: 0.1% F.S;

3. Load resistance: 0-36VDC;

Insulation form:

Steam jacket and water circulation jacket are a layer of cylinder added outside the main pipe of the liquid level gauge for the circulation of steam, circulating water or heat transfer oil. Vacuum jacket is a layer of vacuum cylinder added outside the main tube of the liquid level gauge to insulate the measured medium from the outside. Double layered jacket generally refers to adding a vacuum jacket on top of the steam like hot jacket. The electric heat tracing system wraps an electric heat tracing strip around the main pipe of the liquid level gauge to heat the medium.